Appropriateness Criteria and How Expert Panels Rate When a Procedure Is Worth Doing
Appropriateness criteria are lists of detailed clinical scenarios, each rated by an expert panel for whether a test or procedure would do more good than harm for that kind of patient. Many, including the American College of Radiology (ACR) criteria, are built with the RAND/UCLA Appropriateness Method, in which panellists rate each scenario from 1 to 9 and a statistical rule sorts it into appropriate, uncertain or inappropriate. Health services researchers and economists use them to measure overuse and underuse, but they are judged without regard to cost, so an appropriate procedure is not necessarily good value. Medicare's appropriate use criteria programme for advanced imaging has been paused.
Origins in benefit, harm and the exclusion of cost
The RAND/UCLA user's manual by Fitch and colleagues explains that the method was developed in the mid 1980s, mainly to measure the overuse and underuse of medical and surgical procedures. Trials rarely give evidence detailed enough for the range of patients seen in practice, so the method combines the best available evidence with expert judgement.
A procedure is appropriate when its expected health benefit exceeds its expected negative consequences by a sufficiently wide margin that it is worth doing, exclusive of cost. Panellists are instructed not to consider cost; once a procedure is judged effective, the manual says consumers, patients and payers should then join the discussion. A rating of appropriate is therefore a clinical net-benefit judgement, not a finding of cost-effectiveness.
An early application shaped the economics of variation in care. Chassin and colleagues found coronary angiography performed 2.3 times as often in a high-use Medicare site as in a low-use one, yet 72% of procedures were appropriate in the high-use site against 81% in the low-use site. Differences in appropriateness could not explain the geographic variation.
The RAND/UCLA method step by step
The method turns a literature review into an exhaustive list of indications, each a specific patient description. The earliest RAND panels had 9 members; other studies have used 7 to 15. Panellists rate in a two-round modified Delphi process, first alone at home, then again after a one- or two-day moderated meeting where they see the first-round distribution and discuss disagreements. No attempt is made to force consensus.
Each indication is rated on the benefit-to-harm ratio from 1 (harms greatly outweigh benefits) to 9 (benefits greatly outweigh harms), for an average patient treated by an average physician in an average hospital. The panel median and the presence of disagreement then fix the classification.
| Classification | Rule (RAND/UCLA manual) |
|---|---|
| Appropriate | Median 7 to 9, without disagreement |
| Uncertain | Median 4 to 6, or any median with disagreement |
| Inappropriate | Median 1 to 3, without disagreement |
For a 9-member panel the classic definition of disagreement is at least three panellists rating in the 1 to 3 region and at least three in the 7 to 9 region.
Because counts suit only some panel sizes, the manual also gives a continuous rule, the interpercentile range adjusted for symmetry (IPRAS), defined as follows.
where IPRAS is the interpercentile range (IPR, in the manual's tests the 30th to 70th percentile range) required for disagreement, AI is the asymmetry index (the distance between the central point of the observed IPR and 5, the centre of the scale), 2.35 is the required range under perfect symmetry and 1.5 is the correction factor. An indication is rated with disagreement when its observed IPR exceeds its IPRAS.
A third round can produce necessity criteria, which measure underuse. Only appropriate indications are re-rated, and one is necessary when its necessity median is 7 or more without disagreement; the definition includes that it would be improper care not to offer the procedure.
ACR Appropriateness Criteria for imaging
The ACR Appropriateness Criteria apply the method to imaging and image-guided intervention. The ACR rating process document (revised April 2021) bases the process on the RAND/UCLA manual and adopts its definition of appropriateness, exclusive of cost. The 1 to 9 scale is grouped as usually not appropriate (1 to 3), may be appropriate (4 to 6) and usually appropriate (7 to 9). Panellists rate anonymously in up to two rounds; if disagreement remains after two rounds, the procedure is categorised as may be appropriate and assigned a rating of 5.
Medicare appropriate use criteria under PAMA
The Protecting Access to Medicare Act of 2014 (PAMA), section 218(b), added section 1834(q) to the Social Security Act, directing the Centers for Medicare & Medicaid Services (CMS) to promote appropriate use criteria (AUC) for advanced diagnostic imaging such as CT and MRI. Ordering professionals would consult AUC through a qualified clinical decision support mechanism, payment would depend on the claim reporting that consultation, and outlier ordering professionals would face prior authorisation.
A voluntary period began in July 2018 and an education and operations testing period, with no claim denials, in January 2020. In the calendar year 2024 Physician Fee Schedule final rule (88 FR 78818), CMS paused the programme for re-evaluation and rescinded its regulations at 42 CFR 414.94 from 1 January 2024. It judged real-time claims-based reporting an insurmountable barrier, because the claims system could not reliably tell which claims were subject to the programme, risking inappropriate denials. The CMS programme page, checked on 4 October 2026, still describes the pause, gives no timeframe for restarting, and states that CMS no longer qualifies criteria developers or decision support mechanisms.
Evidence on reliability and validity
Reproducibility was tested by Shekelle and colleagues, who ran three parallel nine-member panels each for coronary revascularisation and hysterectomy. The three-way kappa for detecting overuse was 0.52 and 0.51 respectively, and 0.83 for underuse of revascularisation. Applying different panels' criteria to the same patients produced a 100% variation in the proportion classified as inappropriate. The authors concluded that the criteria may help compare populations but should not by themselves direct individual care.
Panel make-up matters. The manual reports that same-specialty panels rate more indications appropriate than multispecialty panels, and that panellists who perform the procedure rate highest. Bernstein and colleagues applied US and Dutch panels' ratings to the same 3,080 angina patients and found poor agreement for angioplasty (kappa 0.03) and only slight agreement for bypass surgery (kappa 0.18).
Predictive validity is more encouraging. In a prospective study at three London hospitals, Hemingway and colleagues found that of 1,353 patients for whom bypass surgery was rated appropriate, 26% were treated medically, and these patients had a higher risk of death or non-fatal myocardial infarction (hazard ratio 4.08), with a graded relation between rating and outcome across the scale.
Effects on use and spending
The Medicare Imaging Demonstration, from 2011, exposed ordering clinicians to imaging appropriateness guidelines through decision support. Its final evaluation by Timbie and colleagues found that more than 60% of orders could not be linked to a guideline. In difference-in-differences models the effect on use was statistically significant in only two of seven participating organisations in the main model (one in the baseline-period model), at 1 to 2 fewer procedures per 100 beneficiaries. Physicians reported ordering time rising from 3.9 to 7.2 minutes.
Kuntz and colleagues tested the link with value directly, comparing panel ratings for coronary angiography after myocardial infarction with a decision-analytic model across 36 scenarios. Scenarios rated appropriate had a median gain of 0.59 QALYs at USD 27,000 per QALY gained, against 0.24 QALYs at USD 54,000 for those rated inappropriate. The Spearman correlation between appropriateness score and the ICER was -0.66, but several inappropriate scenarios had ratios comparable with generally recommended interventions.
Worked example of rating three indications and auditing orders
All numbers in this example are illustrative. A nine-member panel rates a hypothetical imaging test for three indications.
| Indication | Ratings (sorted) | Median | Ratings 1 to 3 | Ratings 7 to 9 | Classification |
|---|---|---|---|---|---|
| A | 1, 2, 2, 2, 3, 3, 3, 4, 6 | 3 | 7 | 0 | Inappropriate |
| B | 6, 7, 7, 8, 8, 8, 9, 9, 9 | 8 | 0 | 8 | Appropriate |
| C | 1, 2, 3, 7, 7, 7, 8, 8, 9 | 7 | 3 | 6 | Uncertain (disagreement) |
Indication C has a median of 7, but three ratings fall in each extreme region, meeting the classic definition of disagreement, so it is uncertain.
1. Audit orders. Of 400 orders, 100 match indication A, 240 match B and 60 match C.
where is the share of orders rated inappropriate, is the number of inappropriate orders and is the number of orders audited. At 250 GBP a scan, inappropriate orders account for 25,000 GBP.
2. Swap the panel. A second panel rates indication A as 2, 3, 3, 4, 4, 4, 5, 6, 7. The median is 4 and there is no disagreement, so A becomes uncertain and the inappropriate share falls to 0. One indication crossing a boundary changes measured overuse completely, a simple version of the panel-to-panel variation Shekelle and colleagues found.
3. Cost a decision support rule. Suppose decision support adds 3.3 minutes per order (7.2 minus 3.9, the demonstration's reported times), clinician time costs 2 GBP a minute, and 10 of the 100 inappropriate orders are cancelled.
where is the net budget effect in GBP, is the number of cancelled scans, is the price per scan in GBP, is the added minutes per order and is the cost of a clinician minute in GBP.
Under these assumptions the avoided scans do not pay for the clinician time, before counting health effects or any underuse revealed. Inappropriate orders measure quality, not recoverable savings.
Boundaries with nearby concepts
Appropriateness criteria sit between clinical judgement and economic evaluation. Several nearby ideas are easily confused with them.
- A clinical guideline gives recommendations; appropriateness criteria rate every scenario in an exhaustive matrix, reporting uncertain ones as such.
- Appropriate care is the goal; the criteria operationalise it for one procedure, and necessity is the stricter standard used for underuse.
- Utilisation review and prior authorisation are payer processes that may apply criteria case by case.
- Cost-effectiveness analysis adds costs and compares the result with a cost-effectiveness threshold; appropriateness ratings leave costs out.
Where appropriateness ratings are misread
The method has a long record, but its outputs are easy to over-read. Four errors recur.
- Treating ratings as a gold standard for individual patients. The manual calls them a starting point for discussion, and Shekelle and colleagues advise against using them alone to direct care.
- Equating inappropriate use with recoverable spending. Overuse and underuse can coexist, and acting on the criteria has its own costs.
- Ignoring panel composition. Specialty mix and nationality shift ratings, so transferred criteria need checking against local evidence.
- Reading appropriate as cost-effective. Cost is excluded by design, so appropriate procedures can still fail a value test, and some inappropriate ones can pass it.
Sources
- American College of Radiology. ACR Appropriateness Criteria Rating Process: Rating Round Information. Revised April 2021. https://edge.sitecorecloud.io/americancoldf5f-acrorgf92a-productioncb02-3650/media/ACR/Files/Clinical/Appropriateness-Criteria/Rating-Round-Information.pdf
- Bernstein SJ, Hofer TP, Meijler AP, Rigter H. Setting standards for effectiveness: a comparison of expert panels and decision analysis. International Journal for Quality in Health Care. 1997;9(4):255-263. https://doi.org/10.1093/intqhc/9.4.255
- Centers for Medicare & Medicaid Services. Appropriate Use Criteria Program. Accessed 4 October 2026. https://www.cms.gov/medicare/quality/appropriate-use-criteria-program
- Centers for Medicare & Medicaid Services. CY 2024 Payment Policies Under the Physician Fee Schedule (final rule). Federal Register. 2023;88:78818-80047, section III.J. https://www.federalregister.gov/documents/2023/11/16/2023-24184/medicare-and-medicaid-programs-cy-2024-payment-policies-under-the-physician-fee-schedule-and-other
- Chassin MR, Kosecoff J, Park RE, Winslow CM, Kahn KL, Merrick NJ, Keesey J, Fink A, Solomon DH, Brook RH. Does inappropriate use explain geographic variations in the use of health care services? A study of three procedures. JAMA. 1987;258(18):2533-2537. https://pubmed.ncbi.nlm.nih.gov/3312655/
- Fitch K, Bernstein SJ, Aguilar MD, Burnand B, LaCalle JR, Lázaro P, van het Loo M, McDonnell J, Vader JP, Kahan JP. The RAND/UCLA Appropriateness Method User's Manual. MR-1269-DG-XII/RE. Santa Monica, CA: RAND; 2001. https://www.rand.org/pubs/monograph_reports/MR1269.html
- Hemingway H, Crook AM, Feder G, Banerjee S, Dawson JR, Magee P, Philpott S, Sanders J, Wood A, Timmis AD. Underuse of coronary revascularization procedures in patients considered appropriate candidates for revascularization. New England Journal of Medicine. 2001;344(9):645-654. https://doi.org/10.1056/NEJM200103013440906
- Kuntz KM, Tsevat J, Weinstein MC, Goldman L. Expert panel vs decision-analysis recommendations for postdischarge coronary angiography after myocardial infarction. JAMA. 1999;282(23):2246-2251. https://doi.org/10.1001/jama.282.23.2246
- Shekelle PG, Kahan JP, Bernstein SJ, Leape LL, Kamberg CJ, Park RE. The reproducibility of a method to identify the overuse and underuse of medical procedures. New England Journal of Medicine. 1998;338(26):1888-1895. https://doi.org/10.1056/NEJM199806253382607
- Timbie JW, Hussey PS, Burgette LF, Wenger NS, Rastegar A, Brantley I, Khodyakov D, Leuschner KJ, Weidmer BA, Kahn KL. Medicare Imaging Demonstration Final Evaluation: Report to Congress. RR-706-CMS. Santa Monica, CA: RAND; 2014. https://www.rand.org/pubs/research_reports/RR706.html
Related Concepts (5)
Functions & Formulae (3)
a(L_p, U_p, n_L, n_H, k, m) = (DI, D, D_c, APP, UNC, INA)
Disagreement test with the interpercentile range adjusted for symmetry
IPR = U_p - L_p; IPR_c = (L_p + U_p) / 2; AI = abs(5 - IPR_c); IPRAS = 2.35 + 1.5 * AI; DI = IPR / IPRAS; D = (IPR > IPRAS)
Classic count definition of panel disagreement across the two extreme regions
D_c = (n_L >= k) and (n_H >= k)
Appropriate, uncertain or inappropriate class from panel median and disagreement
APP = (m >= 6.5) and (D < 1); INA = (m < 3.5) and (D < 1); UNC = 1 - APP - INA
Library
Publications
10
Appropriate Use Criteria Program — Centers for Medicare & Medicaid Services, Web page, last modified 10 March 2026, accessed 4 October 2026 ed., 2026 (Centers for Medicare & Medicaid Services)
CMS web page on the Appropriate Use Criteria Program for advanced diagnostic imaging, cited for its voluntary period from July 2018, an education and operations testing period from January 2020 without claim denials, the pause and rescission of the regulations at 42 CFR 414.94 from 1 January 2024, and no timeframe for restarting.
Web (Open Access)View source →ACR Appropriateness Criteria Rating Process: Rating Round Information — American College of Radiology, Revised April 2021 ed., 2021 (American College of Radiology)
American College of Radiology description of the rating rounds used to develop the ACR Appropriateness Criteria, cited for basing the process on the RAND/UCLA manual and its definition of appropriateness, anonymised ratings in up to two rounds grouped as usually not appropriate, may be appropriate or usually appropriate, and disagreement after two rounds being rated 5.
Expert panel vs decision-analysis recommendations for postdischarge coronary angiography after myocardial infarction — Kuntz KM, Tsevat J, Weinstein MC, Goldman L, Vol. 282, No. 23, pp. 2246-2251 ed., 1999 (JAMA)
Comparison of expert panel and decision-analysis recommendations for coronary angiography after myocardial infarction in 36 scenarios, cited for median gains of 0.59 QALYs at USD 27,000 per QALY in appropriate scenarios against 0.24 QALYs at USD 54,000 in inappropriate ones, a rank correlation of -0.66 with cost-effectiveness ratios, and some inappropriate scenarios having acceptable ratios.
Journal ArticleView source →Setting standards for effectiveness: a comparison of expert panels and decision analysis — Bernstein SJ, Hofer TP, Meijler AP, Rigter H, Vol. 9, No. 4, pp. 255-263 ed., 1997 (International Journal for Quality in Health Care)
Study comparing expert panel standards with decision analysis for coronary revascularisation, cited for finding poor agreement between US and Dutch panel appropriateness ratings for percutaneous transluminal coronary angioplasty, with a kappa of 0.03, and only slight agreement for bypass surgery, with a kappa of 0.18.
Journal ArticleView source →Underuse of coronary revascularization procedures in patients considered appropriate candidates for revascularization — Hemingway H, Crook AM, Feder G, Banerjee S, Dawson JR, Magee P, Philpott S, Sanders J, Wood A, Timmis AD, Vol. 344, No. 9, pp. 645-654 ed., 2001 (New England Journal of Medicine)
Prospective study of consecutive patients undergoing coronary angiography at three London hospitals, cited for 26% of 1,353 patients for whom bypass surgery was rated appropriate being treated medically and having a higher risk of death or non-fatal myocardial infarction, with a hazard ratio of 4.08, and a graded relation across the appropriateness scale.
Journal ArticleView source →CY 2024 payment policies under the Physician Fee Schedule (final rule) — Centers for Medicare & Medicaid Services, Vol. 88, pp. 78818-80047 (16 November 2023), section III.J ed., 2023 (Federal Register)
Medicare final rule on calendar year 2024 physician fee schedule payment policies, cited for section III.J on the appropriate use criteria programme for advanced diagnostic imaging under section 1834(q) as added by the Protecting Access to Medicare Act 2014, and for pausing it because real-time claims-based reporting was an insurmountable barrier risking inappropriate claim denials.
Web (Open Access)View source →The reproducibility of a method to identify the overuse and underuse of medical procedures — Shekelle PG, Kahan JP, Bernstein SJ, Leape LL, Kamberg CJ, Park RE, Vol. 338, No. 26, pp. 1888-1895 ed., 1998 (New England Journal of Medicine)
Three-way replication of the RAND/UCLA appropriateness method with nine-member panels for coronary revascularisation and hysterectomy, cited for kappa statistics of 0.52 and 0.51 for detecting overuse and 0.83 for underuse of revascularisation, a 100 percent variation in cases classed as inappropriate, and advice that the criteria should not by themselves direct individual care.
Journal ArticleView source →The RAND/UCLA Appropriateness Method User's Manual — Fitch K, Bernstein SJ, Aguilar MD, Burnand B, LaCalle JR, Lázaro P, van het Loo M, McDonnell J, Vader JP, Kahan JP, MR-1269-DG-XII/RE ed., 2001 (RAND)
RAND manual for the RAND/UCLA Appropriateness Method, cited for its development in the mid 1980s to measure overuse and underuse, defining appropriate care as expected benefit exceeding harm by a margin worth doing exclusive of cost, two-round modified Delphi ratings on a 1 to 9 scale, median and disagreement rules, necessity criteria and panel composition effects.
Does inappropriate use explain geographic variations in the use of health care services? A study of three procedures — Chassin MR, Kosecoff J, Park RE, Winslow CM, Kahn KL, Merrick NJ, Keesey J, Fink A, Solomon DH, Brook RH, Vol. 258, No. 18, pp. 2533-2537 ed., 1987 (JAMA)
Study of whether inappropriate use explains geographic variation in three procedures among sampled Medicare beneficiaries, cited for coronary angiography being performed 2.3 times as often in the high-use site, with 72% of procedures appropriate there against 81% in the low-use site, and the conclusion that appropriateness differences cannot explain the variation.
Journal ArticleView source →Medicare Imaging Demonstration Final Evaluation: Report to Congress — Timbie JW, Hussey PS, Burgette LF, Wenger NS, Rastegar A, Brantley I, Khodyakov D, Leuschner KJ, Weidmer BA, Kahn KL, RR-706-CMS ed., 2014 (RAND)
RAND evaluation for Congress of the Medicare Imaging Demonstration, which from 2011 tested exposing ordering clinicians to appropriateness guidelines for advanced imaging, cited for more than 60% of orders not being linked to a guideline, significant reductions in only two of seven conveners of 1 to 2 procedures per 100 beneficiaries, and ordering time rising from 3.9 to 7.2 minutes.
Frequently Asked Questions (6)
What are appropriateness criteria?
Appropriateness criteria are expert panel ratings of when a procedure's benefit exceeds its harms enough to be worth doing, exclusive of cost.
Source: Fitch et al. 2001
What standards for judging a procedure are appropriateness criteria?
Appropriateness criteria are a structured set of standards used to judge whether a procedure is clinically appropriate for a patient. They are developed by expert consensus, a panel agreeing what counts as appropriate for defined clinical situations. They are used to judge whether a specific procedure fits a particular patient, matching the case against the standards. They are a structured set of standards, an organised framework rather than loose guidance. They put appropriateness into practice, turning the abstract benefit-harm judgement into workable rules. Consensus standards for judging procedures are what they name. Brook and colleagues (1986) set this out.
Source: Brook et al. 1986
How are appropriateness criteria developed?
Appropriateness criteria are developed by expert consensus, so the structured set of standards used to judge whether a procedure is clinically appropriate is produced by experts agreeing. This development by expert consensus defines them. So appropriateness criteria are a structured set of standards, developed by expert consensus, used to judge whether a specific procedure is clinically appropriate for a patient This use in judging appropriateness is what appropriateness criteria serve for a specific procedure and patient.
Source: Brook et al. 1986
What are appropriateness criteria used to judge?
Appropriateness criteria are used to judge whether a specific procedure is clinically appropriate for a patient, so the structured standards help decide whether a procedure suits a particular patient. This use in judging appropriateness defines them. So appropriateness criteria are a structured set of standards, developed by expert consensus, used to judge whether a specific procedure is clinically appropriate for a patient This character as a structured set of standards is what makes appropriateness criteria a defined basis for judging procedures.
Source: Brook et al. 1986
What kind of thing are appropriateness criteria?
Appropriateness criteria are a structured set of standards, so they are an organised set of standards, developed by expert consensus, used to judge whether a specific procedure is clinically appropriate for a patient. This character as a structured set of standards defines them. So appropriateness criteria are a structured set of standards, developed by expert consensus, used to judge whether a specific procedure is clinically appropriate for a patient.
Source: Brook et al. 1986
How do appropriateness criteria relate to appropriateness?
Appropriateness criteria relate to appropriateness as the standards to the judgement they support: appropriateness is a judgement of whether a procedure's expected benefit exceeds its expected negatives by enough to justify it, and appropriateness criteria are a structured set of standards used to judge whether a procedure is clinically appropriate. So appropriateness criteria guide the appropriateness judgement, connected as the standards and the judgement they inform.
Source: Brook et al. 1986
Trust Record
Verified by Dr Darrin Baines
British health economist
Professional identity: darrinbaines.org
Verification date: 27 Oct 2026
Content version: 1.0.1
Canonical Identity
- Term code
- HS-NHS-HQ-005
Stable URI · Machine-readable · Resolvable · CC BY 4.0