Signature
APP = (m >= 6.5) and (D < 1); INA = (m < 3.5) and (D < 1); UNC = 1 - APP - INA
| Inputs | Definition | Unit |
|---|---|---|
m | Median of the panel's ratings of the indication on the 1 to 9 scale, possibly ending in .5 for an even panel | rating points |
D | Equals 1 when the chosen test, D of HE-FM-APPC-001 or D_c of HE-FM-APPC-002, finds disagreement and 0 otherwise | indicator |
APP | Equals 1 when the median is at least 6.5 without disagreement and 0 otherwise | indicator |
|---|---|---|
INA | Equals 1 when the median is below 3.5 without disagreement and 0 otherwise | indicator |
UNC | Equals 1 when the indication is neither appropriate nor inappropriate and 0 otherwise | indicator |
Function
RAND/UCLA appropriateness classification of a clinical indication from panel ratings
Maps the 1 to 9 ratings that an expert panel gives one clinical indication to a measure of disagreement and a class of appropriate, uncertain or inappropriate. HE-FM-APPC-001 gives the continuous disagreement test with the interpercentile range adjusted for symmetry, HE-FM-APPC-002 the classic count of ratings in the two extreme regions, and HE-FM-APPC-003 the class from the panel median and either test. In the article's audit of orders, the share rated inappropriate is a plain proportion of the form of the first part of HE-FM-PR-001, P_1 = a / (a + b), with a the inappropriate orders and b the rest, so it is not restated. The article's net budget effect of decision support is HE-FM-BIA-001 with the sign reversed, where E_A_t is (N minus n_c) p plus N t w and E_R_t is N p (derived), with t in those two terms the added minutes per order of the article and not the period of the live record, so it is not restated either. A class leaves cost out by design, so a comparison with value goes through a ratio such as HE-FM-ICER-001. Notation follows the Appropriateness Criteria article.
Computational function
Computational function for panel ratings to disagreement tests and appropriateness class
Takes the ratings of one indication and returns its median, both disagreement tests and the class under each, running HE-FM-APPC-001, HE-FM-APPC-002 and HE-FM-APPC-003 in one pass. The calculator line is written for a panel of nine sorted ratings, where linear interpolation falls at positions 3.4 and 6.6, and the Excel, R and Python code take any panel size.
Inputs and outputs:
r_1tor_9are the nine ratings sorted in ascending order on the 1 to 9 scale. The chain returns the medianm, the limitsL_pandU_p,IPR,IPR_c,AI,IPRAS,DIandDas in HE-FM-APPC-001, the countsn_Landn_HandD_cas in HE-FM-APPC-002 with k of 3, the class indicatorsAPP,INAandUNCunderD, andAPP_c,INA_candUNC_cunderD_c.Assumption: As in HE-AS-APPC-001, HE-AS-APPC-002, HE-AS-APPC-004 and HE-AS-APPC-006. The ratings must be sorted before they enter the calculator line. The code sorts them itself. For a panel outside 8 to 16 the count result is NA in R, None in Python and #N/A in Excel, while the range test still returns a value.
Worked example (article indication C): With
r_1 = 1; r_2 = 2; r_3 = 3; r_4 = 7; r_5 = 7; r_6 = 7; r_7 = 8; r_8 = 8; r_9 = 9the chain givesm = 7; L_p = 4.6; U_p = 7.6; IPR = 3; IPR_c = 6.1; AI = 1.1; IPRAS = 4; DI = 0.75; D = 0; n_L = 3; n_H = 6; D_c = 1; APP = 1; INA = 0; UNC = 0; APP_c = 0; INA_c = 0; UNC_c = 1. The range test classes the indication appropriate and the count test, used in the article, classes it uncertain. The ratings are illustrative.Worked example (article indication A): With
r_1 = 1; r_2 = 2; r_3 = 2; r_4 = 2; r_5 = 3; r_6 = 3; r_7 = 3; r_8 = 4; r_9 = 6the chain givesm = 3; L_p = 2; U_p = 3; IPR = 1; IPR_c = 2.5; AI = 2.5; IPRAS = 6.1; DI = 0.1639; D = 0; n_L = 7; n_H = 0; D_c = 0; APP = 0; INA = 1; UNC = 0; APP_c = 0; INA_c = 1; UNC_c = 0. Both tests class it inappropriate, as the article does.Excel: Use the cells of HE-IM-APPC-001, HE-IM-APPC-002 and HE-IM-APPC-003 on one range PanelRatings, entering the second formula of HE-IM-APPC-003 twice, once with DisagreementFlag in a cell named ClassByRange and once with ClassicDisagreementFlag in a cell named ClassByCount, for example
=IF(ClassicDisagreementFlag,"Uncertain",IF(PanelMedian>=6.5,"Appropriate",IF(PanelMedian>=3.5,"Uncertain","Inappropriate"))). Repeat the block on its own sheet for each indication, with the names scoped to that sheet, because a block copied on one sheet still reads the same PanelRatings range.R:
appc <- function(x) { if (length(x) == 0) stop("no ratings"); r <- sort(x); n <- length(r); k <- if (n >= 8 && n <= 16) round(n/3) else NA; L <- quantile(r, 0.3, names = FALSE, type = 7); U <- quantile(r, 0.7, names = FALSE, type = 7); IPR <- U-L; AI <- abs(5-(L+U)/2); IPRAS <- 2.35+1.5*AI; D <- IPR > IPRAS; nL <- sum(r <= 3); nH <- sum(r >= 7); Dc <- nL >= k && nH >= k; m <- median(r); cls <- function(d) if (is.na(d)) NA else if (d) "Uncertain" else if (m >= 6.5) "Appropriate" else if (m >= 3.5) "Uncertain" else "Inappropriate"; list(m = m, L = L, U = U, IPR = IPR, AI = AI, IPRAS = IPRAS, DI = IPR/IPRAS, D = D, nL = nL, nH = nH, k = k, Dc = Dc, class_range = cls(D), class_count = cls(Dc)) }appc(c(1, 1, 1, 2, 3, 3, 6, 6, 6, 6, 8, 8))returns L 2.3, U 6, DI 1.0207, D TRUE, Dc FALSE, class_range Uncertain and class_count Uncertain (median 4.5). An empty vector stops with the message no ratings, and a single rating returns an IPR of 0, D FALSE and class_count NA.Python:
def appc(x): r = sorted(x); n = len(r); assert n > 0, 'no ratings'; pct = lambda p: r[int((n-1)*p)] + ((n-1)*p-int((n-1)*p))*(r[min(int((n-1)*p)+1, n-1)]-r[int((n-1)*p)]); L, U = pct(0.3), pct(0.7); IPR = U-L; AI = abs(5-(L+U)/2); IPRAS = 2.35+1.5*AI; D = IPR > IPRAS; nL = sum(v <= 3 for v in r); nH = sum(v >= 7 for v in r); k = round(n/3) if 8 <= n <= 16 else None; Dc = None if k is None else (nL >= k and nH >= k); m = (r[(n-1)//2]+r[n//2])/2; cls = lambda d: None if d is None else 'Uncertain' if d else 'Appropriate' if m >= 6.5 else 'Uncertain' if m >= 3.5 else 'Inappropriate'; return dict(m=m, L=L, U=U, IPR=IPR, AI=AI, IPRAS=IPRAS, DI=IPR/IPRAS, D=D, nL=nL, nH=nH, k=k, Dc=Dc, class_range=cls(D), class_count=cls(Dc))appc([1, 1, 2, 2, 3, 3, 3, 3, 7, 7, 7, 8])returns L 2.3, U 5.8 and DI 0.9272 (to floating point), D False, Dc True, class_range Inappropriate and class_count Uncertain (median 3). An empty list raises AssertionError, and a single rating returns an IPR of 0, D False and class_count None.Test (manual first example): With the 12 ratings of the first example in PanelRatings, LowerLimitIPR and UpperLimitIPR are compared with the printed 2.3 and 6.0 and ClassicDisagreementFlag must be FALSE. Expected result TRUE. PERCENTILE.EXC returns limits of 1.9 and 6 and FALSE, and doubling LowerLimitIPR to 4.6 or halving it to 1.15 also gives FALSE. Excel check
=AND(ABS(LowerLimitIPR-2.3)<0.0005,ABS(UpperLimitIPR-6)<0.0005,NOT(ClassicDisagreementFlag))Test (manual second example): With the 12 ratings of the second example in PanelRatings, the two class cells must differ, as the two tests do on this example, and IPRange must equal the printed 3.5. Expected result TRUE. A ClassByRange cell fed by ClassicDisagreementFlag makes both labels Uncertain and returns FALSE, and doubling IPRange to 7 or halving it to 1.75 also gives FALSE. Excel check
=AND(ClassByRange="Inappropriate",ClassByCount="Uncertain",ABS(IPRange-3.5)<0.0005)Common error (unsorted ratings in the calculator line): The chain reads ratings by position. Article indication C entered in descending order gives
L_p = 7.6andU_p = 4.6, an IPR of -3 and D of 0, a negative range that no panel can have (computed here).Source: Fitch K, Bernstein SJ, Aguilar MD, Burnand B, LaCalle JR, Lázaro P, van het Loo M, McDonnell J, Vader JP, Kahan JP. The RAND/UCLA Appropriateness Method User's Manual. MR-1269-DG-XII/RE. Santa Monica, CA: RAND; 2001. Chapter 8 as in HE-SR-APPC-001, HE-SR-APPC-005 and HE-SR-APPC-006. The interpolation that reproduces the printed limits is derived here.
m = r_5; L_p = r_3 + 0.4 * (r_4 - r_3); U_p = r_6 + 0.6 * (r_7 - r_6); IPR = U_p - L_p; IPR_c = (L_p + U_p) / 2; AI = abs(5 - IPR_c); IPRAS = 2.35 + 1.5 * AI; DI = IPR / IPRAS; D = (IPR > IPRAS); n_L = (r_1 <= 3) + (r_2 <= 3) + (r_3 <= 3) + (r_4 <= 3) + (r_5 <= 3) + (r_6 <= 3) + (r_7 <= 3) + (r_8 <= 3) + (r_9 <= 3); n_H = (r_1 >= 7) + (r_2 >= 7) + (r_3 >= 7) + (r_4 >= 7) + (r_5 >= 7) + (r_6 >= 7) + (r_7 >= 7) + (r_8 >= 7) + (r_9 >= 7); D_c = (n_L >= 3) and (n_H >= 3); APP = (m >= 6.5) and (D < 1); INA = (m < 3.5) and (D < 1); UNC = 1 - APP - INA; APP_c = (m >= 6.5) and (D_c < 1); INA_c = (m < 3.5) and (D_c < 1); UNC_c = 1 - APP_c - INA_c
Try this function
Implementations
Excel
Appropriateness class label from panel median and disagreement flag
With the ratings in PanelRatings and the chosen test's result in a cell named DisagreementFlag, the two formulas return cells named PanelMedian and AppropriatenessClass. MEDIAN ignores blank and text cells and returns #NUM! for an empty range. A blank DisagreementFlag is read by IF as FALSE, so a test left unrun reads as no disagreement.
=MEDIAN(PanelRatings); =IF(DisagreementFlag,"Uncertain",IF(PanelMedian>=6.5,"Appropriate",IF(PanelMedian>=3.5,"Uncertain","Inappropriate")))
Assumptions
Treatment of medians of 3.5 and 6.5 from an even panel
An even panel can return a median on a boundary. The manual calls including these medians in the higher category the most common approach and notes that it is biased towards making indications appropriate. Its alternative, round to the middle, classes both as uncertain, which in this formula only raises the upper cut-off to 7, since 3.5 is already uncertain (derived).
Class formed without regard to cost
Panellists are instructed not to consider cost, and appropriate means that expected health benefit exceeds expected negative consequences by a sufficiently wide margin that the procedure is worth doing, exclusive of cost. The class therefore holds no information on cost.
Necessity rating as a separate later step
Underuse rests on a further round in which only appropriate indications are re-rated. The manual judges one necessary when its necessity rating is 7 or more without disagreement. That round has its own median and disagreement, and they do not enter this formula.
Worked examples
Article indication B classed appropriate
Indication B in the article has a median of 8 and no disagreement, so it is appropriate. The ratings are illustrative.
m = 8; D = 0; APP = 1; INA = 0; UNC = 0
Article indication A classed inappropriate
Indication A in the article has a median of 3 and no disagreement, so it is inappropriate. The ratings are illustrative.
m = 3; D = 0; APP = 0; INA = 1; UNC = 0
Article indication C uncertain under the classic count
Indication C in the article has a median of 7, but the classic count finds disagreement, so it is uncertain. The ratings are illustrative.
m = 7; D = 1; APP = 0; INA = 0; UNC = 1
Second panel moves article indication A to uncertain
The article's second panel gives indication A a median of 4 without disagreement, so it moves to uncertain. The ratings are illustrative.
m = 4; D = 0; APP = 0; INA = 0; UNC = 1
Even panel median of 6.5 classed appropriate
An illustrative median of 6.5 from an even panel without disagreement is appropriate under the most common approach in the manual.
m = 6.5; D = 0; APP = 1; INA = 0; UNC = 0
Even panel median of 3.5 classed uncertain
An illustrative median of 3.5 from an even panel without disagreement is uncertain under the same approach, since the higher category for 3.5 is uncertain.
m = 3.5; D = 0; APP = 0; INA = 0; UNC = 1
Common errors
Reading the panel median without the disagreement test
A median of 7 does not make an indication appropriate. Article indication C has that median, with three ratings of 1 to 3 and six of 7 to 9, and is uncertain by the classic count.
Reading appropriate as cost-effective
Kuntz and colleagues found a median of 0.59 QALYs and USD 27,000 per QALY gained in scenarios rated appropriate, against 0.24 QALYs and USD 54,000 in those rated inappropriate, yet several scenarios judged inappropriate had cost-effectiveness ratios comparable with many generally recommended interventions. A value judgement needs a ratio such as HE-FM-ICER-001 and a threshold, which the class does not supply.
Reading an ACR rating of 5 as a panel median
The American College of Radiology groups the scale in the same three bands, but when disagreement remains after two rounds the rating is categorised as may be appropriate and 5 is the assigned rating. A published 5 can therefore mark a split panel with any median, and cannot be read as a central view (derived).
Treating one panel's inappropriate share as fixed
In the article's illustration the share of orders rated inappropriate, a proportion of the form of the first part of HE-FM-PR-001, falls from 0.25 to 0 when a second panel moves one indication from inappropriate to uncertain. Shekelle and colleagues report a 100 percent variation in the proportion of cases classified as inappropriate when different panels' criteria were applied, and conclude that the criteria should not by themselves be used to direct care for individual patients.
Sources
RAND/UCLA manual on the appropriateness classes and even panels
Fitch K, Bernstein SJ, Aguilar MD, Burnand B, LaCalle JR, Lázaro P, van het Loo M, McDonnell J, Vader JP, Kahan JP. The RAND/UCLA Appropriateness Method User's Manual. MR-1269-DG-XII/RE. Santa Monica, CA: RAND; 2001. Chapter 8, section Operational Definitions of Levels of Appropriateness, page 56, gives appropriate as a panel median of 7-9 without disagreement, uncertain as a median of 4-6 or any median with disagreement, and inappropriate as a median of 1-3 without disagreement, and sets out the two treatments of medians of 3.5 and 6.5. Chapter 6, page 30, gives the definition of appropriateness exclusive of cost and the instruction to panellists not to consider cost implications, and Chapter 1, page 6, states the rule for necessity.
American College of Radiology rating process for disagreement
American College of Radiology. ACR Appropriateness Criteria Rating Process: Rating Round Information. Revised April 2021. The process is based on the RAND/UCLA manual, the scale is grouped as usually not appropriate (1, 2 or 3), may be appropriate (4, 5 or 6) and usually appropriate (7, 8 or 9), and if there is still disagreement after two rounds the rating is categorised as may be appropriate and 5 is the assigned rating.
Kuntz and colleagues comparing panel ratings with decision analysis
Kuntz KM, Tsevat J, Weinstein MC, Goldman L. Expert panel vs decision-analysis recommendations for postdischarge coronary angiography after myocardial infarction. JAMA. 1999;282(23):2246-2251. doi:10.1001/jama.282.23.2246. The abstract gives the median health gains and incremental cost-effectiveness ratios by rating and states that several scenarios judged inappropriate had cost-effectiveness ratios comparable with many generally recommended medical interventions.
Shekelle and colleagues on the reproducibility of appropriateness ratings
Shekelle PG, Kahan JP, Bernstein SJ, Leape LL, Kamberg CJ, Park RE. The reproducibility of a method to identify the overuse and underuse of medical procedures. New England Journal of Medicine. 1998;338(26):1888-1895. doi:10.1056/NEJM199806253382607. The abstract reports a 100 percent variation in the proportion of cases classified as inappropriate and concludes that the criteria should not by themselves be used to direct care for individual patients.
Canonical Identity