Functions & Formulae

Each applied formula has its own function page, with a signature, implementations, and tests.

RAND/UCLA appropriateness classification of a clinical indication from panel ratings

a(L_p, U_p, n_L, n_H, k, m) = (DI, D, D_c, APP, UNC, INA)

Maps the 1 to 9 ratings that an expert panel gives one clinical indication to a measure of disagreement and a class of appropriate, uncertain or inappropriate. HE-FM-APPC-001 gives the continuous disagreement test with the interpercentile range adjusted for symmetry, HE-FM-APPC-002 the classic count of ratings in the two extreme regions, and HE-FM-APPC-003 the class from the panel median and either test. In the article's audit of orders, the share rated inappropriate is a plain proportion of the form of the first part of HE-FM-PR-001, P_1 = a / (a + b), with a the inappropriate orders and b the rest, so it is not restated. The article's net budget effect of decision support is HE-FM-BIA-001 with the sign reversed, where E_A_t is (N minus n_c) p plus N t w and E_R_t is N p (derived), with t in those two terms the added minutes per order of the article and not the period of the live record, so it is not restated either. A class leaves cost out by design, so a comparison with value goes through a ratio such as HE-FM-ICER-001. Notation follows the Appropriateness Criteria article.

  • Disagreement test with the interpercentile range adjusted for symmetry

    IPR = U_p - L_p; IPR_c = (L_p + U_p) / 2; AI = abs(5 - IPR_c); IPRAS = 2.35 + 1.5 * AI; DI = IPR / IPRAS; D = (IPR > IPRAS)

    Compares the spread of the middle of the panel's ratings with the spread required to call them disagreement. IPR is the distance between the 30th and 70th percentiles of the ratings, and its required value IPRAS rises with AI, the distance of the central point of that range from 5, the centre of the 1 to 9 scale, because asymmetric ratings need a wider range before they count as disagreement. An indication is rated with disagreement when IPR exceeds IPRAS, and a value exactly on IPRAS is not disagreement. The manual sets 2.35 and 1.5 as the values that best reproduce the classic count definition, HE-FM-APPC-002, in its data sets, and the measure was built to apply to any panel size. The ratio DI is the disagreement index of later applications, and it is above 1 exactly when D is 1 (derived, since IPRAS is always positive).

  • Classic count definition of panel disagreement across the two extreme regions

    D_c = (n_L >= k) and (n_H >= k)

    Counts the panellists who rate an indication in each extreme region of the 1 to 9 scale, 1 to 3 and 7 to 9. Disagreement is present when both counts reach k. For a panel of nine the classic definition sets k at 3, and Table 4 of the manual extends it to 3 for panels of 8 to 10, 4 for 11 to 13 and 5 for 14 to 16. Ratings scattered widely that miss k in one region, as in the manual's first example, are not disagreement under this rule, one of the limitations the manual says HE-FM-APPC-001 would seem to solve.

  • Appropriate, uncertain or inappropriate class from panel median and disagreement

    APP = (m >= 6.5) and (D < 1); INA = (m < 3.5) and (D < 1); UNC = 1 - APP - INA

    Sorts one indication into a class with the panel median and a disagreement indicator from HE-FM-APPC-001 or HE-FM-APPC-002. A median in the top third without disagreement is appropriate and a median in the bottom third without disagreement is inappropriate. Every other case is uncertain, including any median with disagreement. The cut-offs of 6.5 and 3.5 give the manual's bands of 7 to 9, 4 to 6 and 1 to 3 for whole medians, and they apply its most common approach for an even panel, with 6.5 appropriate and 3.5 uncertain. Exactly one of the three indicators equals 1 for any input (derived).

This set of formulae is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/concept/appropriateness-criteria/formulae