Classic count definition of panel disagreement across the two extreme regions

Counts the panellists who rate an indication in each extreme region of the 1 to 9 scale, 1 to 3 and 7 to 9. Disagreement is present when both counts reach k. For a panel of nine the classic definition sets k at 3, and Table 4 of the manual extends it to 3 for panels of 8 to 10, 4 for 11 to 13 and 5 for 14 to 16. Ratings scattered widely that miss k in one region, as in the manual's first example, are not disagreement under this rule, one of the limitations the manual says HE-FM-APPC-001 would seem to solve.

Signature

D_c = (n_L >= k) and (n_H >= k)
Inputs
InputsDefinitionUnit
n_LNumber of panellists whose rating of the indication is 1, 2 or 3panellists
kCount required in each extreme region for the panel's size, read from Table 4 of the manual; 3, 4 or 5panellists
n_HNumber of panellists whose rating of the indication is 7, 8 or 9panellists
Output
D_cEquals 1 when at least k panellists rate in each extreme region and 0 otherwiseindicator

Function

RAND/UCLA appropriateness classification of a clinical indication from panel ratings

Maps the 1 to 9 ratings that an expert panel gives one clinical indication to a measure of disagreement and a class of appropriate, uncertain or inappropriate. HE-FM-APPC-001 gives the continuous disagreement test with the interpercentile range adjusted for symmetry, HE-FM-APPC-002 the classic count of ratings in the two extreme regions, and HE-FM-APPC-003 the class from the panel median and either test. In the article's audit of orders, the share rated inappropriate is a plain proportion of the form of the first part of HE-FM-PR-001, P_1 = a / (a + b), with a the inappropriate orders and b the rest, so it is not restated. The article's net budget effect of decision support is HE-FM-BIA-001 with the sign reversed, where E_A_t is (N minus n_c) p plus N t w and E_R_t is N p (derived), with t in those two terms the added minutes per order of the article and not the period of the live record, so it is not restated either. A class leaves cost out by design, so a comparison with value goes through a ratio such as HE-FM-ICER-001. Notation follows the Appropriateness Criteria article.

Try this function

Implementations

  • Excel

    Classic disagreement flag from a named range of panel ratings

    With the ratings of one indication in PanelRatings, the four formulas return, in order, cells named LowRatingCount, HighRatingCount, ExtremeCountRequired and ClassicDisagreementFlag. ROUND of the panel size over 3 reproduces Table 4 at every panel size in the table (derived, and checked here), and any other size returns #N/A, which passes through to the flag. COUNT and COUNTIF skip blank cells, so a blank rating lowers the panel size and does not count as a low rating.

    =COUNTIF(PanelRatings,"<=3"); =COUNTIF(PanelRatings,">=7"); =IF(AND(COUNT(PanelRatings)>=8,COUNT(PanelRatings)<=16),ROUND(COUNT(PanelRatings)/3,0),NA()); =AND(LowRatingCount>=ExtremeCountRequired,HighRatingCount>=ExtremeCountRequired)

Assumptions

  • Required count taken from the manual table for the panel size

    k comes from Table 4 of the manual, which covers panels of 8 to 16. The classic definition itself is stated for a panel of nine, and the records do not extend the table beyond those sizes.

  • Count definition suits panels that are multiples of three

    The manual states that the definitions work well for panels that are multiples of three, where disagreement means at least one third of panellists in each extreme. Within each size group it reports a bias, with less disagreement for the smallest panels and more for the largest.

Worked examples

  • Article indication C meets the classic count

    Indication C in the article has three ratings of 1 to 3 and six of 7 to 9 from nine panellists, so both counts reach 3 and the ratings are in disagreement. The ratings are illustrative.

    n_L = 3; n_H = 6; k = 3; D_c = 1
  • Second panel rating of article indication A misses the classic count

    The second panel in the article rates indication A as 2, 3, 3, 4, 4, 4, 5, 6 and 7. Three ratings fall in the lower region and one in the upper, so there is no disagreement. The ratings are illustrative.

    n_L = 3; n_H = 1; k = 3; D_c = 0
  • Manual first example under the count for a panel of twelve

    The manual's first example has six ratings in the 1 to 3 range and two in the 7 to 9 range from 12 panellists. Table 4 sets k at 4, so the manual finds no disagreement by this rule.

    n_L = 6; n_H = 2; k = 4; D_c = 0
  • Manual second example under the count for a panel of twelve

    The manual's second example has eight ratings in the 1 to 3 range and four in the 7 to 9 range from 12 panellists. Both counts reach 4, so the manual finds disagreement by this rule.

    n_L = 8; n_H = 4; k = 4; D_c = 1

Common errors

  • Requiring only one extreme region for classic disagreement

    Both regions must reach k. Using or in place of and marks the manual's first example, with six low ratings and two high ones, as disagreement when the manual finds none by this rule, and a panel with almost every rating at one extreme would count as split.

  • Using the count for nine on a larger panel

    A required count of 3 on a panel of 12 is below the 4 in Table 4. Illustrative counts of three low and three high ratings from 12 panellists then return disagreement when the table returns none.

  • Treating the count and range tests as interchangeable

    The two tests give opposite verdicts on both of the manual's examples and on article indication C, where D is 0 with a DI of 0.75 and D_c is 1. The manual reports 21 false negatives and 75 false positives for IPRAS against the classic definition in an initial test on 5,566 indications from 6 data sets. A report should name the test that fixed each class.

Sources

  • RAND/UCLA manual on the classic definition and panel sizes

    Fitch K, Bernstein SJ, Aguilar MD, Burnand B, LaCalle JR, Lázaro P, van het Loo M, McDonnell J, Vader JP, Kahan JP. The RAND/UCLA Appropriateness Method User's Manual. MR-1269-DG-XII/RE. Santa Monica, CA: RAND; 2001. Chapter 8, section Operational Definitions of Levels of Disagreement. Page 58 gives the classic definition for a 9-member panel, at least three panellists in the 1-3 region and at least three in the 7-9 region. Page 59, Table 4, gives the numbers for panels of 8-10, 11-13 and 14-16, and the following text says that the definitions work well for multiples of three and are biased within each group. Page 61, in section Development of the "IPRAS", reports the initial test against the classic definition, with 21 false negatives and 75 false positives in 5,566 indications from 6 data sets.

    View source →

Canonical Identity

This formula is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/formula/classic-count-definition-of-panel-disagreement-across-the-two-extreme-regions