Input Data Validation

Input data validation checks that the data feeding a health economic model are appropriate, well sourced, suitably transformed and adequately fitted.

Status
Published, version 1.0.0
Last reviewed
11 Nov 2026, by Dr Darrin Baines
Report a problem
Tell us if something is wrong or out of date

Concept Architecture

Input Data Validation in Health Economic Models

Input data validation asks whether the evidence feeding a health economic model is fit for the decision the model informs. It traces where each probability, cost, utility and treatment effect came from, whether that source suits the decision's population and setting, and whether published figures became model parameters by sound methods. A model free of coding errors, with a sensible structure, still gives misleading cost-effectiveness results if its inputs are biased or badly fitted. Health technology assessment reviewers therefore check the evidence behind each important input as well as the model.

Input data among the parts of model validation

For model validation, Feenstra and colleagues adopt the categories of operations research simulation, namely conceptual model validation, input data validation, computerised model validation (also called code verification) and operational validation. The AdViSHE tool of Vemer and colleagues follows this order, and its Part B, input data validation, has two items. Conceptual Model Validation comes first and judges the structure the data will populate.

Sargent's nearest term is data validity, which he notes is often not counted as part of model validation. It covers data for building, testing and running the model, including observed system data later compared with model output, which health economists discuss under External Validation. He files fitting distributions and estimating parameters under conceptual model validity, work AdViSHE places under item B2. He adds that data problems often explain failed validation attempts and recommends internal consistency checks and outlier screening.

Choosing the right evidence and methods is validation, while checking that input calculations were carried out as intended is verification. The TECH-VER checklist of Büyükkaramikli and colleagues treats input, or pre-analysis, calculations as its first verification domain, covered on the Technical Verification page.

What is checked for each input

AdViSHE asks modellers to show where inputs are described and justified. Its list covers the search strategy, the data sources, reasons for including or excluding sources, assumptions for parameters with no data, the distributions representing uncertainty, and data adjustments such as transformations, the treatment of outliers and missing data, synthesis by network meta-analysis and calibration.

Item B1 is face validity testing of the input data, in which experts judge whether appropriate data were used. The tool asks who the experts were and how far they agreed, and suggests they judge potential for bias and generalisability to the target population. The ISPOR-SMDM report by Eddy and colleagues likewise asks, under face validity, whether the best available data sources were used.

Item B2, model fit testing, applies when input parameters come from regression models, such as survival curves for disease progression or the mapping of disease-specific quality of life scores to utility values. AdViSHE's example tests include comparing the Akaike information criterion and Bayesian information criterion, comparing alternative specifications and survival distributions, and inspecting goodness of fit and residuals visually.

What HTA bodies ask of model inputs

NICE PMG36 (2022, updated 2026) asks in paragraph 4.6.3 that data inputs be clearly documented and justified in the context of a valid review of the alternatives. Paragraph 4.6.15 asks for the methods used to identify and critically evaluate data sources, with the choice of data sets justified by suitability to the population of interest, and 4.6.16 asks the same for sources of baseline risk. Paragraph 4.6.18 says underlying assumptions should be checked statistically whenever possible. For extrapolation beyond the trial, paragraph 4.6.20 asks that the limitations of statistical fit measures be documented and that external validity be judged by plausibility and coherence with external data such as historical cohorts.

Inputs from registries or routine records fall under the NICE real-world evidence framework (ECD9), which asks for data of good and known provenance that are fit for purpose. It splits fitness for purpose into data quality, the completeness and accuracy of key variables, and data relevance, which includes differences in patients, interventions and care settings between the data and the NHS target population.

How reviewers find problems in inputs

The TECH-VER paper reports input calculation errors from NICE appraisals as verification findings. For pomalidomide with dexamethasone in multiple myeloma, the company's weekly resource use differed sharply from the review group's rough estimate, because an annual figure had been converted into a weekly probability instead of being divided by 52.

TECH-VER also suggests comparing modelled with trial median survival when the trial supplied the inputs. Eddy and colleagues call a validation dependent when the same source was used both to estimate model parameters and to validate the model, and they want validation sources to be independent where feasible. Such a check confirms that inputs were carried through and says little about accuracy in new settings.

Thorn and colleagues tested Hospital Episode Statistics with NHS reference costs against medical record review for final-year inpatient costs of 292 men in the CAP trial. Mean costs differed by GBP 899, with the routine data about 8% lower (p = 0.3), and they judged the routine data usable as the primary costing method in large trials, though neither source is a gold standard.

Worked example with a progression probability and a survival curve

All numbers in this example are illustrative. A model of a chronic disease runs in monthly cycles and takes progression on standard care from a registry in which 40% of patients had progressed within five years. The reviewer first confirms that the registry population and definition of progression match the scope.

1. Check the conversion method. The model uses 0.40 divided by 60, or 0.00667, as the monthly probability. Choosing the method is an input data question, though TECH-VER also lists checking time conversions for probabilities as a verification test. Assuming a constant rate, a rate-to-probability conversion gives

r=−ln⁡(1−P)t=−ln⁡(0.60)5=0.51085=0.1022p=1−e−r/12=1−e−0.008514=0.00848r = \frac{-\ln(1 - P)}{t} = \frac{-\ln(0.60)}{5} = \frac{0.5108}{5} = 0.1022 \qquad p = 1 - e^{-r/12} = 1 - e^{-0.008514} = 0.00848

where rr is the annual progression rate, PP is the cumulative probability over the period, tt is the period in years, pp is the monthly transition probability and 12 is the number of cycles in a year. Division suits an expected count, as in the pomalidomide case, not a cumulative probability.

2. Reproduce the source figure. Both inputs are run over 60 cycles.

1−(1−0.00667)60=1−0.6693=0.33071−(1−0.00848)60=1−0.5999=0.40011 - (1 - 0.00667)^{60} = 1 - 0.6693 = 0.3307 \qquad 1 - (1 - 0.00848)^{60} = 1 - 0.5999 = 0.4001

where 60 is the number of monthly cycles in five years. The model's input of 0.00667 gives 33% progression at five years against the 40% observed, because its monthly transition probability is about 21% too low (0.00667 divided by 0.00848 is 0.787). The constant-rate assumption also needs justifying, since a rising hazard would shift progression later.

3. Test the fit of a survival input. Overall survival on standard care is fitted to 250 trial patients with three distributions.

AIC=2k−2ln⁡LBIC=kln⁡n−2ln⁡L\text{AIC} = 2k - 2\ln L \qquad \text{BIC} = k\ln n - 2\ln L

where kk is the number of estimated parameters, ln⁡L\ln L is the maximised log-likelihood and nn is the number of patients, so that ln⁡250=5.521\ln 250 = 5.521.

Distributionkln LAICBIC
Exponential1-412.6827.2830.7
Weibull2-405.1814.2821.2
Log-normal2-406.9817.8824.8

The Weibull curve is lowest on both measures, 3.6 below the log-normal on each. This ranking describes fit within the trial only, so the reviewer also compares the extrapolated tail with registry survival and clinical opinion, which is work for External Validation and Face Validity. The fit statistics answer AdViSHE item B2, while comparing the tail with registry data is item D4, validation against empirical data.

Where input data validation stops

A common form of calibration constrains unobservable parameters by matching model output to external data, and Eddy and colleagues ask reports to state the target, goodness-of-fit metric, search algorithm, acceptance criteria and stopping rule. A calibrated input is checked through its targets and fitting method, and a close fit to those targets is not independent external validation.

A surrogate endpoint that drives outcomes needs its own evidence. PMG36 paragraph 4.6.7 treats a surrogate as validated only when the relative effect of a technology on it predicts the relative effect on the final outcome, and 4.6.8 says this is specific to the population and technology type. Rerunning the model on a different data source, AdViSHE item D3, tests results and belongs to operational validation.

Limits and common misreadings

Reporting of input checks remains thin. In a systematic review of 78 early breast cancer model studies published between 2016 and 2024, Abraham and colleagues found expert validation of input data, the only category to improve significantly, reported in 20% (16 of 78), against 2% (1 of 48) between 2008 and 2015 in a set built on de Boer and colleagues' earlier review. Statistical tests for input data were reported in 3% (2 of 78), against 13% before, though such tests may not suit every study. They add that the line between input and outcome validation can blur, as with fitted survival curves.

Two misreadings are common.

  1. Reading the best-fitting curve as validated for the extrapolated period. Fit statistics describe the observed data only.
  2. Reading reuse as justification. An earlier model's source still needs justifying against the alternatives.

Sources

  • Abraham K, Corro Ramos I, Braal CL, Feenstra T, Kleijburg A, van Voorn GAK, Uyl-de Groot C. Under-reporting of validation efforts for health economic models persists despite the availability of validation tools: a systematic review. PharmacoEconomics. 2025;43:849-858. https://doi.org/10.1007/s40273-025-01491-2
  • Büyükkaramikli NC, Rutten-van Mölken MPMH, Severens JL, Al M. TECH-VER: a verification checklist to reduce errors in models and improve their credibility. PharmacoEconomics. 2019;37(11):1391-1408. https://doi.org/10.1007/s40273-019-00844-y
  • Eddy DM, Hollingworth W, Caro JJ, Tsevat J, McDonald KM, Wong JB. Model transparency and validation: a report of the ISPOR-SMDM Modeling Good Research Practices Task Force-7. Value in Health. 2012;15(6):843-850. https://doi.org/10.1016/j.jval.2012.04.012
  • Feenstra T, Corro-Ramos I, Hamerlijnck D, van Voorn G, Ghabri S. Four aspects affecting health economic decision models and their validation. PharmacoEconomics. 2022;40:241-248. https://doi.org/10.1007/s40273-021-01110-w
  • National Institute for Health and Care Excellence. NICE real-world evidence framework (ECD9). Published 23 June 2022, minor changes September 2025. https://www.nice.org.uk/corporate/ecd9/chapter/assessing-data-suitability
  • National Institute for Health and Care Excellence. NICE technology appraisal and highly specialised technologies guidance: the manual (PMG36). Published 31 January 2022, last updated 13 October 2026. Sections 4.6.3 to 4.6.20. https://www.nice.org.uk/process/pmg36
  • Sargent RG. Verification and validation of simulation models. In: Jain S, Creasey RR, Himmelspach J, White KP, Fu M, eds. Proceedings of the 2011 Winter Simulation Conference. IEEE; 2011:183-198. https://www.informs-sim.org/wsc11papers/016.pdf
  • Thorn JC, Turner EL, Hounsome L, Walsh E, Down L, Verne J, Donovan JL, Neal DE, Hamdy FC, Martin RM, Noble SM. Validating the use of Hospital Episode Statistics data and comparison of costing methodologies for economic evaluation: an end-of-life case study from the Cluster randomised triAl of PSA testing for Prostate cancer (CAP). BMJ Open. 2016;6(4):e011063. https://doi.org/10.1136/bmjopen-2016-011063
  • Vemer P, Corro Ramos I, van Voorn GAK, Al MJ, Feenstra TL. AdViSHE: a validation-assessment tool of health-economic models for decision makers and model users. PharmacoEconomics. 2016;34(4):349-361. https://doi.org/10.1007/s40273-015-0327-2

Frequently Asked Questions (6)

  • What is Input Data Validation?

    Input data validation checks that the data feeding a health economic model are appropriate, well sourced, suitably transformed and adequately fitted.

    Source: Vemer et al. 2016

  • How is input data validation carried out on a health economic model?

    The AdViSHE tool of Vemer and colleagues sets out input data validation as two items in its Part B. Item B1 asks whether experts have judged the appropriateness of the input data, who those experts were and how far they agreed, with potential for bias and generalisability to the target population among the aspects to judge. Item B2 applies when parameters come from regression models, such as survival curves for disease progression or mapping to utility values, and asks for model fit tests such as comparing the Akaike and Bayesian information criteria, alternative specifications and visual checks of fit. The modeller also states where each data source and data adjustment is described and justified.

    Source: Vemer et al. 2016

  • What does NICE expect from input data validation in a technology appraisal?

    The NICE manual, PMG36 (2022, updated 2026), asks in paragraph 4.6.3 that data inputs be clearly documented and justified in the context of a valid review of the alternatives. Paragraph 4.6.15 asks for the methods used to identify and critically evaluate data sources, with each chosen data set justified by its suitability to the population of interest, and paragraph 4.6.16 applies the same to sources of baseline risk. Paragraph 4.6.18 adds that underlying assumptions should be checked statistically whenever possible. A reviewer of a submission can therefore ask, for each important input, why that source was chosen over the alternatives and whether it suits the population in the scope.

    Source: NICE PMG36 (2022, updated 2026)

  • How does input data validation differ from verification of a model's input calculations?

    Input data validation asks whether the right evidence and methods were chosen, while checking that input calculations were carried out as intended is verification. The TECH-VER checklist of Büyükkaramikli and colleagues treats these input, or pre-analysis, calculations as its first verification domain and reports errors of this kind from NICE appraisals. In the appraisal of pomalidomide with dexamethasone for multiple myeloma, the company's weekly resource use differed sharply from the review group's rough estimate, because an annual figure had been converted into a weekly probability instead of being divided by 52. HTA model reviewers look for both kinds of problem, since a correctly calculated input can still come from an unsuitable source.

    Source: Büyükkaramikli et al. 2019

  • Why does a well-fitting survival curve not settle input data validation?

    Fit statistics such as the Akaike and Bayesian information criteria rank candidate distributions only by how well they describe the observed trial data. The extrapolated tail beyond the trial is not tested by that ranking, so a reviewer also compares it with registry survival and clinical opinion. NICE PMG36 (2022, updated 2026), in paragraph 4.6.20, asks that the limitations of statistical fit measures be documented and that the external validity of an extrapolation be judged by clinical and biological plausibility and by coherence with external data such as historical cohorts. Checking the tail in this way draws on external validation and face validity as well as on input data validation.

    Source: NICE PMG36 (2022, updated 2026)

  • How often do published model studies report input data validation?

    In a systematic review of 78 early breast cancer model studies published between 2016 and 2024, Abraham and colleagues found expert validation of input data reported in 20% (16 of 78), against 2% (1 of 48) between 2008 and 2015, the only validation category to improve significantly. Statistical tests for input data were reported in 3% (2 of 78), against 13% in the earlier period, though the authors note that such tests may not suit every study. They add that the line between input and outcome validation can blur, as with fitted survival curves, which complicates any count of input checks.

    Source: Abraham et al. 2025

Trust Record

Verified by Dr Darrin Baines

British health economist

Professional identity: darrinbaines.org

Verification date: 11 Nov 2026

Content version: 1.0.0

Canonical Identity

Term code
HE-EM-MV-096

Stable URI · Machine-readable · Resolvable · CC BY 4.0

This article is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/concept/input-data-validation