Face Validity of Health Economic Models

Face validity asks whether people who know the disease and the decision problem would accept a health economic model as a fair picture of both. In health technology assessment it covers the model's structure, its data, the framing of the question and its results. Expert review needs no observed outcome data, so it can be done on any model, including one for a technology with no long-term evidence yet. Its evidence is limited, since agreement among experts shows only that a model matches current beliefs, which can be wrong.

Face validity among the types of model validation

The ISPOR-SMDM task force report on model transparency and validation by Eddy and colleagues lists face validity first among five types of validation. It describes face validity as the extent to which a model, its assumptions and its applications correspond to current science and evidence, as judged by people with expertise in the problem. The same report calls external and predictive validation the strongest forms, and the model validation page compares all five.

Face validity is a validation question, about whether the model is the right one for the decision. Verification asks whether the model was built right, the subject of the Technical Verification page. Eddy and colleagues note that verification does not evaluate the accuracy of a model's structure or predictions. The reverse also holds, since experts reading a model diagram cannot see a mistyped cell reference.

Simulation science uses the term in a similar sense, for the conceptual model and for model output. Sargent defines it as asking people who know the system whether the model and its behaviour are reasonable, and names it, with traces, as one of the two primary techniques for conceptual model validation. His validation procedure asks for at least face validity on the conceptual model in each iteration. In measuring patient-reported outcomes the term means something else, whether the items of a questionnaire look like an adequate reflection of the construct, and the content validity page covers it.

The four aspects experts judge

Eddy and colleagues name four aspects as particularly important, which are model structure, data sources, problem formulation and results. The AdViSHE validation-assessment tool by Vemer and colleagues asks modellers to report expert review of three of them as separate items.

AspectQuestion in the ISPOR-SMDM reportAdViSHE item
StructureWhether the model includes all aspects of reality experts consider important, related in ways consistent with medical scienceA1, face validity of the conceptual model
Data sourcesWhether the best available data sources were usedB1, face validity of the input data
Problem formulationWhether setting, population, interventions, outcomes, assumptions and time horizon match those of interestPartly covered within A1 (comparators, perspective, costs covered)
ResultsWhether results match experts' expectations and, if not, whether the model can plausibly explain themD1, face validity of the model outcomes

Where experts find a weakness, the Eddy report asks how well the modellers have reported and explained the discrepancy and its likely effect on the results. Its example is a model that omits an important risk factor, where the modellers should describe the direction and likely size of the resulting bias. The clinical plausibility page covers the clinical side of these judgements, including survival extrapolation.

Who reviews the model and how the review is run

The Eddy report lists several routes. The developing group can ask members of the modelling group, colleagues who did not build the model or external consultants. Peer review usually includes some judgement of face validity, though the report finds peer review of models for publication too inconsistent to be relied on for this purpose.

Two safeguards follow from the subjective nature of the check. Evaluators should have no stake in the problem, and ideally the structure, evidence and problem formulation are assessed without knowing the results. Recommendation VII-3 of the report asks for impartial experts in the problem area, preferably blinded to the results, a description of the process available on request, and discussion in the report of any questions raised.

AdViSHE turns this into reporting. For each of items A1, B1 and D1 the modellers say who the experts were, why they count as experts and how far they agreed, or why no such review was done. Feenstra and colleagues argue that patients can also judge a conceptual model, though as primary stakeholders they can easily appear biased.

What HTA bodies and reviewers look for

NICE PMG36 (2022, updated 2026) builds expert involvement into its modelling methods. Paragraph 4.6.3 asks for details of expert involvement in developing the conceptual model, such as the number of experts, their role and how they were chosen. Paragraph 4.6.18 says models for cost-utility analyses should be informed by the natural history of the disease and checked for clinical plausibility. Paragraph 4.6.19 says assumptions should, when appropriate, be validated by a user of the technology with experience of it in the NHS or by a user with appropriate expertise, which it calls particularly relevant for medical devices. Paragraph 4.6.4 asks for the methods and results of model validation.

In Canada, the CADTH model validation tool described by Coyle and colleagues includes the item that the model structure has been validated by clinical experts. If the model has not been validated by a clinical expert and patients in the field, the tool states that it is unknown whether the structure and assumptions are appropriate, which restricts the applicability of the model's conclusions.

Independence of experts comes up repeatedly. Corro Ramos and colleagues list addressing conflicts of interest when experts are involved among the elements of model validation, and name NICE External Assessment Groups as independent validators who can give an impartial assessment. In a pilot review of 77 company cost-effectiveness analyses at the French HAS, Ghabri and colleagues suggest that validation was scarce partly because it needs external experts without conflicts of interest. A reviewer reading a submission can therefore ask who the experts were, whether they were independent of the company, what they saw and when, and which disagreements changed the model.

Reporting remains thin. In a systematic review of early breast cancer models published 2016 to 2024, Abraham and colleagues found that expert review of input data was reported in 20% of studies (16 of 78), against 2% (1 of 48) for 2008 to 2015, a comparison set built on an earlier review by de Boer and colleagues. This was the only significant improvement they found. Expert review of the conceptual model was reported in 10% (8 of 78) against 8% (4 of 48).

Worked example of blinded expert review of model outcomes

This example is illustrative. A cohort model of a chronic disease predicts survival on standard care for an NHS population. Before seeing any model output, four clinicians with no tie to the company are asked for the proportion of patients they expect to be alive at five years on standard care. Their answers are 30%, 35%, 40% and 35%.

pˉ=0.30+0.35+0.40+0.354=1.404=0.35\bar{p} = \frac{0.30 + 0.35 + 0.40 + 0.35}{4} = \frac{1.40}{4} = 0.35

where pˉ\bar{p} is the mean expert estimate of five-year survival, and the four terms in the numerator are the individual estimates.

The model predicts 52% alive at five years on standard care. The gap from the expert mean is

d=pm−pˉ=0.52−0.35=0.17d = p_{m} - \bar{p} = 0.52 - 0.35 = 0.17

where dd is the difference in survival proportions and pmp_{m} is the model's predicted five-year survival. The model sits 17 percentage points above the expert mean and 12 points above the highest single estimate (0.52 minus 0.40).

The Eddy question for results is whether the model can plausibly explain the gap. The modellers first rule out a coding error, a verification task covered on the Black-Box Testing page. They then find that the trial population was much younger than NHS patients and that the model used the trial's starting age for background mortality and for age-dependent disease risks. With the NHS starting age the model predicts 38%, inside the experts' range of 30% to 40%. The submission reports the experts' roles and independence, the blinded elicitation, the original 52%, the change made and any disagreement that remains.

Agreement after the change shows only that the model now matches what clinicians expect. Whether 38% is close to what happens to patients needs comparison with observed data, the subject of the External Validation and Predictive Validation pages.

Limits of expert judgement and common misreadings

The Eddy report sets out several limits. All models simplify, so a structure may not fully match medical knowledge and would fail a strict test of face validity. Physicians know that a few discrete states and fixed cycle lengths are clinically unrealistic, yet a Markov model built that way can be accurate enough for a well-chosen problem. Medical knowledge can be wrong, and the report recalls that virtually all experts once expected raising high-density lipoprotein cholesterol to prevent cardiovascular events, so a model leaving that effect out would have looked implausible until a trial contradicted the belief. There are no unambiguous criteria, virtually all modellers say their own model has face validity, and anyone with a stake may accept a model whose results they like.

Feenstra and colleagues add that for complex models the conceptual model, input data analysis and code are harder to review at face value, while model outcomes need attention whatever the complexity.

A common misreading reports expert approval as if it validated the whole model, when it says nothing about calculations or about accuracy against observed outcomes. Another treats a plausible-looking structure as settling structural uncertainty, when several structures may look equally reasonable to experts and still give different cost-effectiveness results.

Sources

  • Abraham K, Corro Ramos I, Braal CL, Feenstra T, Kleijburg A, van Voorn GAK, Uyl-de Groot C. Under-reporting of validation efforts for health economic models persists despite the availability of validation tools: a systematic review. PharmacoEconomics. 2025;43:849-858. https://doi.org/10.1007/s40273-025-01491-2
  • Corro Ramos I, Feenstra T, Ghabri S, Al M. Evaluating the validation process: embracing complexity and transparency in health economic modelling. PharmacoEconomics. 2024;42:715-719. https://doi.org/10.1007/s40273-024-01364-0
  • Coyle D, Haines A, Lee K. The development of a model validation tool to assist in the conduct of economic evaluations. Canadian Journal of Health Technologies. 2024;4(3). https://doi.org/10.51731/cjht.2024.862
  • Eddy DM, Hollingworth W, Caro JJ, Tsevat J, McDonald KM, Wong JB. Model transparency and validation: a report of the ISPOR-SMDM Modeling Good Research Practices Task Force-7. Value in Health. 2012;15(6):843-850. https://doi.org/10.1016/j.jval.2012.04.012
  • Feenstra T, Corro-Ramos I, Hamerlijnck D, van Voorn G, Ghabri S. Four aspects affecting health economic decision models and their validation. PharmacoEconomics. 2022;40:241-248. https://doi.org/10.1007/s40273-021-01110-w
  • Ghabri S, Stevenson M, Möller J, Caro JJ. Trusting the results of model-based economic analyses: is there a pragmatic validation solution? PharmacoEconomics. 2019;37:1-6. https://doi.org/10.1007/s40273-018-0711-9
  • Mokkink LB, Prinsen CAC, Patrick DL, Alonso J, Bouter LM, de Vet HCW, Terwee CB. COSMIN methodology for systematic reviews of Patient-Reported Outcome Measures (PROMs): user manual. Version 1.0. Amsterdam: COSMIN; February 2018. https://www.cosmin.nl/wp-content/uploads/COSMIN-syst-review-for-PROMs-manual_version-1_feb-2018.pdf
  • National Institute for Health and Care Excellence. NICE technology appraisal and highly specialised technologies guidance: the manual (PMG36). Published 31 January 2022, last updated 13 October 2026. Sections 4.6.3, 4.6.4, 4.6.18 and 4.6.19. https://www.nice.org.uk/process/pmg36
  • Sargent RG. Verification and validation of simulation models. In: Jain S, Creasey RR, Himmelspach J, White KP, Fu M, eds. Proceedings of the 2011 Winter Simulation Conference. IEEE; 2011:183-198. https://www.informs-sim.org/wsc11papers/016.pdf
  • Vemer P, Corro Ramos I, van Voorn GAK, Al MJ, Feenstra TL. AdViSHE: a validation-assessment tool of health-economic models for decision makers and model users. PharmacoEconomics. 2016;34(4):349-361. https://doi.org/10.1007/s40273-015-0327-2

Library

Publications

1
  • Journal article

    Model Transparency and Validation: A Report of the ISPOR-SMDM Modeling Good Research Practices Task Force-7 — Eddy, Hollingworth, Caro, Tsevat, McDonald & Wong, Task Force Report 7 ed., 2012 (Value in Health / Medical Decision Making)

    Best-practice guidance on model transparency and validation, defining face, internal, external and predictive validation and setting out how models should be documented for scrutiny.

Frequently Asked Questions (6)

  • What is face validity?

    Face validity is expert judgement of whether a health economic model's structure, inputs, problem formulation and results agree with current evidence.

    Source: Eddy et al. 2012

  • What does face validity judge about a model?

    The ISPOR-SMDM report by Eddy and colleagues names four aspects of a health economic model that people with expertise in the problem examine for face validity. For structure, the test is whether the model includes everything experts consider important, related in ways consistent with medical science. For data, it is whether the best available sources were used, and for problem formulation, whether setting, population, interventions, outcomes, assumptions and time horizon match those of interest. Results should match experts' expectations or, failing that, the model should plausibly explain the gap. Where a weakness is found, such as an omitted risk factor, the modellers should report the direction and likely size of the resulting bias.

    Source: Eddy et al. 2012

  • How is face validity assessed?

    Modellers ask experts to review the conceptual model, the input data and the model outcomes. The AdViSHE tool by Vemer and colleagues treats these as separate items, A1, B1 and D1, and for each one asks who the experts were, why they count as experts and how far they agreed that the model is appropriate, or why no such review took place. For the conceptual model, experts judge whether it represents the underlying disease process and whether it suits economic evaluation, for example in its comparators, perspective and costs covered. AdViSHE was built for decision makers and model users, so an HTA reviewer can read these entries to see who judged the model.

    Source: Vemer et al. 2016

  • Why is face validity useful despite being subjective?

    Expert review needs no observed outcome data, so it can be carried out on any model, including one for a technology with no long-term evidence yet. The subjectivity is partly addressed through reporting, so that a reader can weigh who made the judgement. NICE PMG36 (2022, updated 2026) asks for details of expert involvement in developing the conceptual model, such as the number of experts, their role and how they were chosen. It also asks that assumptions be validated, when appropriate, by a user of the technology with experience of it in the NHS or by a user with appropriate expertise, which it calls particularly relevant for medical devices.

    Source: NICE PMG36 (2022, updated 2026)

  • What are the limitations of face validity?

    Agreement among experts shows only that a model matches current beliefs, and medical knowledge can be wrong. Eddy and colleagues recall that virtually all experts once expected raising high-density lipoprotein cholesterol to prevent cardiovascular events, so a model leaving that effect out would have looked implausible until a trial contradicted the belief. All models simplify, and a Markov model with a few discrete states and fixed cycle lengths can be accurate enough for a well-chosen problem even though physicians know it is clinically unrealistic. There are no unambiguous criteria for passing the check, and anyone with a stake in the problem may accept a model whose results they like.

    Source: Eddy et al. 2012

  • How does face validity fit into overall validation?

    Face validity is one of five types of validation named by Eddy and colleagues, alongside verification, cross validity, external validity and predictive validity. It asks whether the model is the right one for the decision, while verification asks whether the model was built right, so expert approval cannot reveal a calculation error such as a mistyped cell reference. The same report calls external and predictive validation the strongest forms, and agreement with experts says nothing about accuracy against observed outcomes. In HTA model review, face validity is therefore one strand of evidence, and a reviewer also looks for verification checks and for comparison of model results with observed data.

    Source: Eddy et al. 2012

Trust Record

Verified by Dr Darrin Baines

British health economist

Professional identity: darrinbaines.org

Verification date: 11 Nov 2026

Content version: 1.0.1

Canonical Identity

Term code
HE-EM-MV-027
Wikidata
Q3737383

Stable URI · Machine-readable · Resolvable · CC BY 4.0

This article is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/concept/face-validity