The CDA-AMC Model Validation Tool is a 53-item checklist from Canada's Drug Agency for checking a health economic model's design, behaviour and coding.

Status
Published, version 1.0.0
Last reviewed
12 Nov 2026, by Dr Darrin Baines
Report a problem
Tell us if something is wrong or out of date

Concept Architecture

CDA-AMC Model Validation Tool for Reviewing Economic Models

The CDA-AMC Model Validation Tool sets out how reviewers at Canada's Drug Agency, and the modellers whose work they review, can judge whether a health economic model addresses the decision problem and calculates its results correctly. A reviewer outside the modelling team answers each of its 53 statements yes, no or not applicable after running and inspecting the model file, so most answers describe the working model rather than its written report. The tool matters in health technology assessment because a model built in Excel or TreeAge is rarely published, so its technical correctness escapes journal peer review and falls to the agency that reviews it.

Origin and name

The tool was developed at CADTH by Coyle, Haines and Lee and published in March 2024. CADTH launched as Canada's Drug Agency (CDA-AMC) on 1 May 2024, and Abraham and colleagues refer to the tool as the CDA-AMC Model Validation Tool. The report itself calls the 53-item list the MVT-53.

The starting point was statement 8.6 of the 2017 CADTH guidelines for economic evaluation, which asks for rigorous internal validation, including quality assurance of all calculations and parameter estimates, with the processes and results reported.

The items came from a grey literature review of agencies including NICE in November 2020, a targeted literature search in April 2021, consultations in March and April 2021 with 6 health economists who review models for agencies in the UK, Ireland and Australia, and a survey of CADTH pharmacoeconomic reviewers in May 2021. A roundtable of Canadian health economists revised the draft, the framework was trialled alongside several CADTH reviews, and the Institut national d'excellence en santé et en services sociaux (INESSS) commented before it was finalised.

The three sections and seven groups of items

The tool has three main sections, divided into seven groups of items. Validation of the conceptual model (items 1 to 25) asks whether the model is the right model for the decision, computer model validation and verification (items 26 to 48) asks whether it behaves and calculates correctly, and general issues of concern (items 49 to 53) lists spreadsheet practices that make checking hard.

GroupItemsWhat the items ask
Decision problem1 to 5Population, subgroups, all current comparators, costs consistent with the stated perspective, outcomes important to clinicians and patients
Model specification6 and 7Structure validated by clinical experts; consistency with previous models or a justification for departing from them
Clinical effectiveness8 to 25Time in health states, events, adverse events, life years and mortality can be extracted and match the evidence; extrapolated data marked; double counting avoided; surrogate links; waning of treatment effect
Model transparency26 to 28Deterministic and single simulation results accessible; a clear trace from every input to the outputs; macros limited
Model behaviour29 to 46Black-box tests on effectiveness, mortality, baseline risk, costs, utilities, discounting, time horizon, swapped inputs and probabilistic output
Model coding47 and 48Working backward from results to inputs and forward from inputs to one simulation's results
General issues49 to 53Error-masking functions and reference functions such as OFFSET and INDIRECT, hidden sheets, rows or columns, user-written VBA functions, macros that reset inputs, inputs not held in one place

Several clinical effectiveness items ask for the outputs that NICE PMG36 (2022, updated 2026) section 4.6.4 asks companies to present, a disaggregated format including life years gained and mortality rates. Item 16 lists four routes by which a technology can change mortality in a model, and item 17 asks whether the model can show which route drives the incremental life years. Item 19 asks for confirmation that the model does not use technology-specific utilities, because a utility gain attached to the drug may repeat an effect already captured through fewer adverse events, the double counting that item 23 also targets.

Validation questions and verification questions

The tool mixes the two questions that model checking keeps apart. Items 1 to 25 are mostly validation, asking whether this is the right model, and the report states that a technically correct model may still be invalid if the decision problem or the clinical pathway is misspecified. Items 26 to 53 are mostly verification, asking whether the model was built right, which is the subject of the technical verification page. Items 9, 11, 13 and 18 compare model output with trial data, real-world evidence or expert opinion, which the report counts as checks of external validity although they sit in the conceptual section. Eddy and colleagues keep external validation for a comparison with actual event data and treat judgement by people with expertise in the problem as face validity. They also call a validation dependent when one source both estimated the parameters and validated the model. The report calls items 29 to 46 black box verification and items 47 and 48 white box verification, while Sargent lists degenerate and extreme condition tests among techniques used for both verification and validation.

Applying the tool to a submitted model

A reviewer works through the items in a fixed order. Conceptual validation comes before the technical checks, and within the technical section the black-box testing of model behaviour precedes white-box testing of the formulas, an order the report stresses. Black-box tests show whether outputs move as expected, and white-box testing then finds the cause of any surprise and checks the coding of every important parameter, because black-box results alone cannot confirm that the model gives correct results.

A no answer leads to one of three consequences. A potential error has been identified, the model is not sufficiently transparent, or the model is not accurately specified. According to the report, the size of the risk depends on the decision problem, and several items carry an instruction to select not applicable, for example item 8 for a decision tree without health states.

The report recommends that the tool be completed by someone not involved in building the model. When the reviewer finds results that cannot be explained, the model should go back to its developer for an explanation. Replication, in which the reviewer recodes much or all of the model, is discussed but left out of the 53 items because it is unlikely to be possible in many cases. For submissions to CADTH, the report is explicit that the tool summarises the agency's approach to model validation and is not a submission requirement.

Worked example applying three behaviour items

All numbers in this example are illustrative. A reviewer applies items 36, 38 and 44 to a three-state Markov model comparing Drug X with standard care over a 10-year horizon, with outcomes left undiscounted for the tests.

1. Item 36, mortality set to zero. With every death probability set to zero, the model reports 10.00 life years in both arms, so the item is answered yes.

2. Item 38, utilities set to one. With all utilities set to 1 and disutilities to 0, the model reports 7.42 QALYs and 7.42 life years for standard care, and 7.88 QALYs against 8.10 life years for Drug X. The Drug X difference of 8.10 minus 7.88, or 0.22, means a QALY loss remains that no utility input explains. The item is answered no, the consequence is a potential error, and white-box testing finds a disutility for infusion visits typed into a QALY formula as a fixed number.

3. Item 44, correlation of costs across simulations. The reviewer shows four of the probabilistic runs. Standard care costs are 10, 12, 14 and 16 thousand Canadian dollars and Drug X costs are 30, 31, 34 and 35 thousand. The Pearson correlation is

r=∑i=1n(xi−xˉ)(yi−yˉ)∑i=1n(xi−xˉ)2∑i=1n(yi−yˉ)2r = \frac{\sum_{i=1}^{n} (x_i - \bar{x})(y_i - \bar{y})}{\sqrt{\sum_{i=1}^{n} (x_i - \bar{x})^2 \sum_{i=1}^{n} (y_i - \bar{y})^2}}

where xix_i is the standard care cost in run ii, yiy_i is the Drug X cost in run ii, xˉ\bar{x} and yˉ\bar{y} are their means, nn is the number of runs and rr is the correlation coefficient. The means are 13 and 32.5. The deviations are minus 3, minus 1, 1 and 3 for standard care and minus 2.5, minus 1.5, 1.5 and 2.5 for Drug X. The sum of products is 7.5 plus 1.5 plus 1.5 plus 7.5, or 18, and the sums of squares are 20 and 17, so r=18/340=18/18.44=0.98r = 18 / \sqrt{340} = 18 / 18.44 = 0.98. Shared parameters such as background mortality move both arms together, so a strong correlation is expected and item 44 is answered yes. A value near zero would suggest that the arms draw separate values for parameters they should share.

4. Reading the result. One no answer among the three items is enough to put the model's results in doubt, and the reviewer returns the model to the developer with the location of the hard-coded value.

Where the tool sits beside AdViSHE and TECH-VER

The report cites AdViSHE and TECH-VER among the published tools it reviewed, and notes that such tools use free text or would likely need their users to have been involved in building the model. Abraham and colleagues describe the CDA-AMC tool as time-efficient verification needing only a third of the black-box tests in TECH-VER, and they note that it was introduced in 2024, so uptake in published studies may still need time.

Limits and common misreadings

Passing is not proof. The report states that the tool encourages good modelling practices but does not necessarily determine good models. A single missing item puts validity in question, while meeting every item makes validity more likely without guaranteeing it.

Evidence quality is outside the tool. The clinical effectiveness items do not judge the quality of the evidence itself, and the report refers users to the CADTH guidelines for evidence appraisal.

Built around Excel and state transition models. Items 28 and 49 to 52 concern Excel functions, hidden rows, columns and sheets, and VBA macros. The clinical effectiveness items apply to state transition models, and some may not apply to decision trees or discrete event simulations.

No score. The tool gives no total or threshold, and the report presents it as good practice guidance and a living document that will be updated in line with modelling practice.

Sensitivity analysis is separate. Items 43 to 46 check that output from probabilistic sensitivity analysis is transparent and behaves as expected, which tests the code. Abraham and colleagues found sensitivity analyses still mistaken for validation in published early breast cancer models, although their purpose is to show the uncertainty of model outcomes and not to judge whether the model, its inputs or its outcomes are valid.

Sources

Frequently Asked Questions (6)

  • What is CDA-AMC Model Validation Tool?

    The CDA-AMC Model Validation Tool is a 53-item checklist from Canada's Drug Agency for checking a health economic model's design, behaviour and coding.

    Source: Coyle et al. 2024

  • How is the CDA-AMC Model Validation Tool used when an HTA reviewer checks a submitted health economic model?

    A reviewer who was not involved in building the model runs and inspects the model file, then answers each of the tool's 53 statements yes, no or not applicable. Conceptual validation of the decision problem and model specification comes first, and within the technical section black-box tests of model behaviour come before white-box checks of the formulas. Each no answer points to a stated consequence, such as a potential error or a model that is not sufficiently transparent. When results cannot be explained, the model goes back to its original developer for an explanation.

    Source: Coyle et al. 2024

  • Is the CDA-AMC Model Validation Tool a requirement for health technology assessment submissions in Canada?

    The 2024 report that sets out the tool states that it summarises the approach taken by CADTH, now Canada's Drug Agency, in model validation, and that it is not a requirement for submissions to CADTH. Its stated aim is a more consistent and reproducible approach to validating economic models of all health technologies. The report presents the tool as an aid for researchers as well as decision makers, so modellers can apply it to their own work, although it recommends that the person completing it was not involved in building the model. The tool gives no total score or pass threshold.

    Source: Coyle et al. 2024

  • Which black-box tests does the CDA-AMC Model Validation Tool ask a reviewer to run on a decision model?

    Items 29 to 46 change inputs and check that the outputs move as expected, without looking at the formulas. Setting the effectiveness of the technologies so that their QALYs are equal should be possible, and setting mortality to zero should give identical life years in every arm. With all utilities set to one and disutilities to zero, QALYs should equal life years. Other items cover discount rates, the time horizon, swapping the inputs of two technologies and the behaviour of probabilistic output. The report treats these as a minimum set, and any unexplained result leads to white-box testing.

    Source: Coyle et al. 2024

  • How does the CDA-AMC Model Validation Tool compare with TECH-VER for verifying a health economic model?

    Abraham and colleagues, reviewing how published early breast cancer models reported validation from 2016 to 2024, describe TECH-VER as an extensive validation exercise that model developers may need time to fit into their workflow. They describe the CDA-AMC Model Validation Tool as a more time-efficient route to model verification that requires only a third of the black-box tests outlined in TECH-VER. Because the tool was introduced in 2024, they note that its uptake in published studies may still need time. Their review found the technical verification of models still under-reported, with sensitivity analyses sometimes mistaken for validation.

    Source: Abraham et al. 2025

  • What can the CDA-AMC Model Validation Tool not show about whether a health economic model is valid?

    The report states that the tool encourages good modelling practices but does not necessarily determine good models. A single missing item puts the validity of a model in question, while meeting every item makes validity more likely without guaranteeing it. The clinical effectiveness items do not judge the quality of the underlying evidence, which the report leaves to the CADTH guidelines on evidence appraisal. Several items concern Excel features, and the clinical effectiveness items are written for state transition models, so some may not apply to decision trees or discrete event simulations. Model replication is discussed but left out of the 53 items.

    Source: Coyle et al. 2024

Trust Record

Verified by Dr Darrin Baines

British health economist

Professional identity: darrinbaines.org

Verification date: 12 Nov 2026

Content version: 1.0.0

Canonical Identity

Term code
HE-EM-MV-114

Stable URI · Machine-readable · Resolvable · CC BY 4.0

This article is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/concept/cda-amc-model-validation-tool