Concept Architecture
Extreme Value Testing of Health Economic Models
Extreme value testing pushes the inputs of a programmed health economic model to zero, to very high levels or to combinations that would never occur in practice, and compares what comes out with what logic demands. A wrong formula can still give believable numbers at base-case inputs, so a model run only near its base case may hide errors that change the cost-effectiveness result. Under extreme inputs the right answer is often obvious, such as no deaths when every mortality input is zero, which makes a fault easy to see. Developers and reviewers of models for health technology assessment meet the test in AdViSHE, where it is item C2, and among the black-box tests of TECH-VER.
Two readings of the same test
The literature gives extreme value testing two jobs. AdViSHE, the validation-assessment tool by Vemer and colleagues, places it under validation of the computerised model, a step its authors note is sometimes called verification, and asks whether the model has been run for specific, extreme sets of parameter values to detect coding errors. Eddy and colleagues, in the ISPOR-SMDM Task Force-7 report, list extreme value analysis among the techniques of verification, which examines whether the mathematical calculations are performed correctly and are consistent with the model's specifications. On this reading the test belongs to technical verification and asks whether the model was built right. In statistics, extreme value analysis names a different method that models the tails of a distribution.
Sargent, writing on simulation models, calls the technique extreme condition tests and asks that model structure and outputs be plausible for any extreme and unlikely combination of levels of factors in the system. He lists it among techniques used in both verification and validation. On this second reading the test also asks whether the structure holds up when inputs leave their usual range, a question of model validation, or whether it is the right model.
One set of extreme runs can expose a coding error and a structural weakness at once, as in the worked example, but the two call for different responses. A coding error is corrected in the code, while a structure that gives impossible results at extreme but legal inputs is a matter for the conceptual model, settled by restricting the input range or by changing how the model is built.
Extreme inputs and the results they should give
Each test pairs an extreme input with a result that can be stated before the model runs. AdViSHE gives examples for item C2, the TECH-VER checklist by Büyükkaramikli and colleagues lists extreme inputs among its black-box tests, and the CDA-AMC Model Validation Tool by Coyle and colleagues, published when the agency was CADTH, includes a test of extremely favourable or unfavourable effectiveness.
| Extreme input | Expected result | Listed in |
|---|---|---|
| All mortality set to zero | Nobody dies, and undiscounted life-years per person equal the time horizon | AdViSHE, TECH-VER |
| Mortality set extremely high | Patients die in the first few cycles | AdViSHE, TECH-VER |
| Effectiveness extremely in favour of, or against, one technology | Substantially greater, or reduced, QALYs for that technology | AdViSHE, CDA-AMC tool |
| All costs set to zero | No costs accumulate at any time | AdViSHE, TECH-VER |
| Discount rates set extremely high | Total discounted results close to those accrued in the first cycles | TECH-VER |
| Adverse event rates set to zero, then extremely high | Lower costs and more QALYs at zero, higher costs and fewer QALYs at the extreme | TECH-VER |
TECH-VER asks the reviewer to build a list for the model at hand. Several zero rows also probe what Sargent calls the degeneracy of model behaviour, which he treats as a separate technique, the degenerate test.
How developers and reviewers run and report the tests
Developers run extreme value tests while building the model, and AdViSHE asks them to say where the tests and their outcomes are reported, or why none were done. Reviewers run them again on the submitted model. TECH-VER expects results in line with prior expectations for extreme value parameters as well as plausible ones. The CDA-AMC tool counts its effectiveness test among a baseline of minimal tests, reads a test that cannot be carried out as a sign that the programming may be inappropriately complex, and recommends sending such a model back to its developer.
Extreme combinations also arise inside a probabilistic sensitivity analysis, where many parameters are drawn at once. TECH-VER asks whether the model passes its black-box tests in all probabilistic iterations, and suggests a macro that stops the run when an error such as a negative transition probability appears.
NICE PMG36 (2022, updated 2026), section 4.6.4, asks companies to detail the quality assurance methods used in developing the model and to provide the methods and results of model validation, which is where a log of extreme value tests belongs. Published studies rarely report them. De Boer and colleagues found no reported validation of the computerised model, extreme value testing included, in published seasonal influenza and early breast cancer models, and two author responses suggested extreme value testing might be regarded as implicit in model development. Abraham and colleagues later found two of 78 early breast cancer model studies reporting it. In an older report on the EVITA varicella vaccination model, Hammerschmidt and colleagues found that varicella death rates of zero yielded no varicella-related deaths, and that zero vaccine efficacy or zero coverage gave the same outcomes in both arms.
Worked example with a hard-coded death probability
All numbers in this example are illustrative. A three-state Markov cohort model with states Well, Sick and Dead runs for two one-year cycles without discounting or half-cycle correction, and the whole cohort starts in Well.
where and are the proportions of the cohort in Well and Sick at the end of cycle , is the annual background mortality probability (0.10) applied in both states, is the excess death probability in Sick (0.10) and is the annual probability that a person in Well becomes Sick (0.10). Life-years per person are the sum of over the two cycles. In the model as received, the Sick death probability is typed into the formula as 0.20 instead of being calculated as .
1. Base case. Cycle 1 leaves Well 0.80 and Sick 0.10, so 0.90 are alive. Cycle 2 leaves Well 0.80 × 0.80, or 0.64, and Sick 0.10 × 0.80 + 0.10 × 0.80, or 0.16, so 0.80 are alive. Life-years total 1.70, and the received model agrees because happens to equal 0.20.
2. Zero mortality. With and both zero, nobody should die. The correct model leaves Well 0.90 and Sick 0.10 after cycle 1, then Well 0.81 and Sick 0.19, everyone alive and 2.00 life-years, the length of the horizon. The received model still removes 20% of Sick each cycle, so cycle 2 leaves Sick 0.10 × 0.80 + 0.09, or 0.17, with 0.98 alive and 1.98 life-years. The test fails, and a search of the Sick formulas finds the hard-coded value.
3. Extremely high mortality. With at 0.90, the Well stay probability is 1 minus 0.90 minus 0.10, or zero, and the Sick death probability is 1.00, so the 0.10 who enter Sick in cycle 1 should all die in cycle 2, giving 0.10 life-years. The received model keeps 0.10 × 0.80, or 0.08, alive in Sick and reports 0.18.
4. Beyond the structure's range. With at 0.95, even the corrected model gives a Well stay probability of 1 minus 0.95 minus 0.10, or minus 0.05, and a negative share of the cohort in Well. This is the plausibility failure Sargent describes. The code matches its specification, but the specification subtracts competing risks in a way that works only while and stay at or below 1, so the developer must restrict the input range or restate the transitions.
5. Why it matters for the decision. A treatment that halves excess mortality in Sick, setting to 0.05, gives a Sick stay probability of 0.85. In the corrected model cycle 2 leaves Sick 0.10 × 0.85 + 0.08, or 0.165, so life-years rise to 0.90 + 0.805, or 1.705, a gain of 0.005 per person over two years. The received model ignores and shows no gain, and a test setting effectiveness equal across arms would pass because both arms already give 1.70.
Extreme value tests, sensitivity analysis and neighbouring checks
Extreme value testing shares its mechanics with sensitivity analysis, since both change inputs and watch outputs. Sensitivity analysis describes how results respond across plausible ranges, while an extreme value test checks the response against a prior expectation to find faults. Eddy and colleagues link the two, saying verification should also involve sensitivity analysis of all parameters over a broad range of input values to see whether the direction and magnitude of outputs behave as expected.
NICE PMG36, section 4.7.4, treats analyses based on demonstrably implausible scenarios for structural uncertainty as useful only when they show that a source of uncertainty does not materially affect the cost-effectiveness conclusion. Extreme value tests have a different purpose, as their results check the model and are not offered to a committee as estimates.
Black-box testing is the wider family of input and output checks within which TECH-VER and the CDA-AMC tool place extreme value tests. Testing of traces, AdViSHE item C3, tracks patients through the model, for example through the cohort trace, to check that its logic is correct.
What a passed test does not show
A passed extreme value test shows only that the model behaved as expected at the values tried. Eddy and colleagues state that verification helps ensure there are no unintentional computational errors but does not evaluate the accuracy of a model's structure or predictions, and step 5 of the example shows an equal-effectiveness test passing on a model that ignores the effect input. Expert judgement of a model's structure and results is the business of face validity, and agreement with observed data that of calibration and external validation.
A failed test is not always a coding error. In the CDA-AMC tool's reading, an unexpected result points either to an error in the code or to an unspecified effect of the technology that may be invalid, and step 4 of the example shows a structural limit rather than a typing mistake.
Sources
- Abraham K, Corro Ramos I, Braal CL, Feenstra T, Kleijburg A, van Voorn GAK, Uyl-de Groot C. Under-reporting of validation efforts for health economic models persists despite the availability of validation tools: a systematic review. PharmacoEconomics. 2025;43:849-858. https://doi.org/10.1007/s40273-025-01491-2
- Büyükkaramikli NC, Rutten-van Mölken MPMH, Severens JL, Al M. TECH-VER: a verification checklist to reduce errors in models and improve their credibility. PharmacoEconomics. 2019;37(11):1391-1408. https://doi.org/10.1007/s40273-019-00844-y
- Coyle D, Haines A, Lee K. The development of a model validation tool to assist in the conduct of economic evaluations. Canadian Journal of Health Technologies. 2024;4(3). https://doi.org/10.51731/cjht.2024.862
- de Boer PT, Frederix GWJ, Feenstra TL, Vemer P. Unremarked or unperformed? Systematic review on reporting of validation efforts of health economic decision models in seasonal influenza and early breast cancer. PharmacoEconomics. 2016;34:833-845. https://doi.org/10.1007/s40273-016-0410-3
- Eddy DM, Hollingworth W, Caro JJ, Tsevat J, McDonald KM, Wong JB. Model transparency and validation: a report of the ISPOR-SMDM Modeling Good Research Practices Task Force-7. Value in Health. 2012;15(6):843-850. https://doi.org/10.1016/j.jval.2012.04.012
- Hammerschmidt T, Goertz A, Wagenpfeil S, Neiss A, Wutzler P, Banz K. Validation of health economic models: the example of EVITA. Value in Health. 2003;6(5):551-559. https://doi.org/10.1046/j.1524-4733.2003.65241.x
- National Institute for Health and Care Excellence. NICE technology appraisal and highly specialised technologies guidance: the manual (PMG36). Published 31 January 2022, last updated 13 October 2026. Sections 4.6.4 and 4.7.4. https://www.nice.org.uk/process/pmg36
- Sargent RG. Verification and validation of simulation models. In: Proceedings of the 2011 Winter Simulation Conference. 2011:183-198. https://www.informs-sim.org/wsc11papers/016.pdf
- Vemer P, Corro Ramos I, van Voorn GAK, Al MJ, Feenstra TL. AdViSHE: a validation-assessment tool of health-economic models for decision makers and model users. PharmacoEconomics. 2016;34(4):349-361. https://doi.org/10.1007/s40273-015-0327-2
Related Concepts (5)
Frequently Asked Questions (6)
What is extreme-value testing?
Extreme value testing runs a health economic model with zero or extreme inputs to check that results stay plausible and to expose coding errors.
Source: Vemer et al. 2016
How does extreme-value testing differ from edge-case testing?
Balci's taxonomy of simulation testing lists extreme input testing, the closest match to extreme-value testing, separately from boundary value testing and has no entry for edge-case testing. Extreme input testing runs a model with only minimum values, only maximum values or a mixture of the two for its inputs. Boundary value testing places test cases just within, on and just outside the limits of input classes within which a model behaves the same way. Edge-case testing, in its usual sense of probing the limits of a valid range, sits closer to boundary value testing. In a health economic model, transition probabilities of 0.999, 1 and 1.001 probe the upper limit of the valid range.
Source: Balci 1998
How is extreme-value testing performed?
Each test pairs an extreme input with a result that can be stated before the model runs. Setting all mortality to zero should mean that nobody dies and that undiscounted life-years per person equal the time horizon, while setting all costs to zero should leave no costs accumulating at any time. The TECH-VER checklist by Büyükkaramikli and colleagues lists such runs among its black-box tests and asks the reviewer to build a list for the model at hand, including very high discount rates and adverse event rates set first to zero and then extremely high. It also asks whether the model passes its black-box tests in all probabilistic iterations.
Source: Büyükkaramikli et al. 2019
Why is extreme-value testing useful?
A model run only near its base case may hide a wrong formula that changes the cost-effectiveness result, because faulty code can still give believable numbers there. Under extreme inputs the correct answer is often obvious, so a fault shows up quickly and can be traced to the formula concerned. Developers run the tests while building a model, and reviewers in health technology assessment run them again on the submitted model. The CDA-AMC Model Validation Tool by Coyle and colleagues counts a test of extremely favourable or unfavourable effectiveness among a baseline of minimal tests, and reads a test that cannot be carried out as a sign that the programming may be inappropriately complex.
Source: Coyle et al. 2024
What does extreme-value testing reveal?
The test can reveal two different kinds of problem in a health economic model. A coding error, such as a death probability typed into a formula instead of being calculated, shows up when zero mortality still removes people from the cohort, and is corrected in the code. Sargent calls the technique extreme condition tests and asks that model structure and outputs be plausible for any extreme and unlikely combination of factor levels, so a run can also expose a structure that gives impossible results, such as a negative share of the cohort when competing risks are subtracted. That second finding is settled by restricting the input range or by changing how the model is built.
Source: Sargent 2011
How does extreme-value testing support verification?
The ISPOR-SMDM task force report by Eddy and colleagues lists extreme value analysis among the techniques of verification, which examines whether the mathematical calculations of a model are performed correctly and are consistent with its specifications. Extreme inputs make errors in those calculations easy to see, so a reviewer of a submitted model gains evidence that the model was built right. The same report states that verification does not evaluate the accuracy of a model's structure or predictions, and a passed test shows only that the model behaved as expected at the values tried. Expert judgement of the model belongs to face validity, and agreement with observed data to calibration and external validation.
Source: Eddy et al. 2012
Trust Record
Verified by Dr Darrin Baines
British health economist
Professional identity: darrinbaines.org
Verification date: 12 Nov 2026
Content version: 1.0.1
Canonical Identity
- Term code
- HE-EM-MV-026
Stable URI · Machine-readable · Resolvable · CC BY 4.0
