Conceptual Model Validation

Conceptual model validation checks that a health economic model's structure, assumptions and pathways fit the disease and the decision problem.

Status
Published, version 1.0.0
Last reviewed
11 Nov 2026, by Dr Darrin Baines
Report a problem
Tell us if something is wrong or out of date

Concept Architecture

Conceptual Model Validation in Health Economic Decision Models

Conceptual model validation asks whether the design of a health economic model represents the disease and the decision problem well enough to inform the decision. It looks at the chosen health states, events, pathways, comparators, costs and assumptions, and at whether experts and earlier models support them. A model can be coded without error and still mislead if its structure leaves out an event that differs between treatments or answers a question the decision maker did not ask. When the check is made before programming, as Law recommends, faults can be fixed on paper before they are coded.

Design validation and code verification

Sargent separates the conceptual model, the mathematical, logical or verbal representation of the system being studied, from the computerised model that implements it. Conceptual model validity in his account means that the theories and assumptions underlying the conceptual model are correct and that its structure, logic and causal relationships are reasonable for the intended purpose. Checking the code against the design is a separate task, computerised model verification. The same split appears in Part A of the AdViSHE tool of Vemer and colleagues and the first section of the model validation tool by Coyle and colleagues for CADTH, now Canada's Drug Agency (CDA-AMC). The ISPOR-SMDM report by Eddy and colleagues judges structure under face validity instead, and the model validation page compares its five types.

Eddy and colleagues note that verification does not evaluate the accuracy of a model's structure, and give the example of a distance problem set up as a weighted sum of rate and time instead of their product, which can be fitted and coded correctly and still be wrong over some ranges of rate and time. The CADTH tool asks for conceptual model validation before verification of the coding, since a technically correct model may still be invalid if the decision problem or the clinical pathway is misspecified. Code checks belong to the Technical Verification page.

What the conceptual model contains

AdViSHE describes a conceptual model as a mathematical, logical, verbal or graphical representation of the underlying system, such as the progression of a disease, and Law describes a written assumptions document that he says has some commonality with a conceptual model. The CADTH tool reviews the decision problem, the model specification and the way clinical effectiveness enters the model, with seven items on the first two parts.

PartWhat is checkedCADTH item
Decision problemModel reflects the population the decision applies to1
Decision problemKey subgroups can be examined2
Decision problemAll comparators in current use are included3
Decision problemCosts match the stated perspective4
Decision problemAll outcomes important to clinicians and patients are included5
Model specificationStructure (process and clinical pathway) validated by clinical experts6
Model specificationStructure follows previous models, or the difference is justified7

A model failing items 1 to 7 can be, in the tool's words, not accurately specified, and its results may then not be useful for decision making however accurate they are. Items 8 to 25 turn to clinical effectiveness, such as duration of effect, where the tool records a failure as a lack of transparency or a potential error.

How a conceptual model is validated

Sargent names face validation and traces as the primary techniques, with experts examining the flowchart or equations and traces following entities through each submodel to check the logic. AdViSHE item A1 asks whether experts judged the appropriateness of the conceptual model, who they were, why they count as experts and how far they agreed, for both the representation of the disease and fitness for economic evaluation. The Face Validity page covers how such reviews are run.

AdViSHE item A2 asks whether the conceptual model was compared with other conceptual models in the literature or clinical textbooks. De Boer and colleagues describe a breast cancer study that compared its conceptual model with all earlier models of the same intervention found by systematic review. This comparison, and the comparison of model outcomes with other models, is covered on the Cross Validity page.

Sargent also asks for assumptions to be tested statistically on data and for a check that each theory was applied correctly, such as whether the system has the Markov property when a Markov chain is used, which in a state transition model is the question of whether the Markov assumption suits the disease.

Law recommends a structured walk-through of the assumptions document with subject-matter experts before programming, moving on only when everyone agrees each point is correct. In one of his projects the experts found a significant share of the sponsor's assumptions wrong.

What NICE asks for and what reviewers find

Paragraph 4.6.3 of the NICE technology appraisal manual, NICE PMG36 (2022, updated 2026), asks that the conceptual model development process used to choose the model structure be transparent and justified, with details of expert involvement such as the number of experts and how they were chosen. Prior use of a structure in published models or earlier NICE submissions is not enough, and the model type and structure should be justified for each new decision problem. Paragraph 4.6.18 asks that models be informed by the natural history of the disease and checked for clinical plausibility, and 4.6.19 that assumptions be validated, when appropriate, by a user of the technology with NHS experience or a user with appropriate expertise.

A reviewer in health technology assessment, such as a NICE External Assessment Group, can ask of a company model whether its diagram and assumptions are documented, which experts shaped them, whether earlier models were reviewed and departures explained, and whether any event that differs between treatments is left out.

Reporting remains thin. In 78 early breast cancer models published in 2016 to 2024, Abraham and colleagues found expert review of the conceptual model reported in 10% (8 of 78) and comparison with the literature in 12% (9 of 78), against 8% (4 of 48) and 6% (3 of 48) for 2008 to 2015.

Worked example of an omitted adverse event found at the walk-through

This example is illustrative. A draft model of a new treatment for a chronic condition has three health states, stable, progressed and dead. At the walk-through two clinicians note that the treatment causes a serious adverse event needing hospital admission, which the draft omits. Before programming, the modellers apply the criterion of Hammerschmidt and colleagues that a model should omit only aspects that do not significantly alter its results and conclusions. Rough estimates give an extra cost of GBP 12,000 and a gain of 0.50 QALYs.

ICER0=ΔCΔE=12,0000.50=24,000\text{ICER}_{0} = \frac{\Delta C}{\Delta E} = \frac{12{,}000}{0.50} = 24{,}000

where ICER0\text{ICER}_{0} is the incremental cost-effectiveness ratio without the event in GBP per QALY, ΔC\Delta C is the incremental cost in GBP and ΔE\Delta E is the incremental QALYs.

Trial data suggest the event affects 10 percentage points more patients on the new treatment, at GBP 6,000 and 0.05 QALYs per event.

ICER1=ΔC+Δp×ceΔE−Δp×qe=12,000+0.10×6,0000.50−0.10×0.05=12,6000.495=25,455\text{ICER}_{1} = \frac{\Delta C + \Delta p \times c_{e}}{\Delta E - \Delta p \times q_{e}} = \frac{12{,}000 + 0.10 \times 6{,}000}{0.50 - 0.10 \times 0.05} = \frac{12{,}600}{0.495} = 25{,}455

where ICER1\text{ICER}_{1} is the ratio with the event, Δp\Delta p is the difference between arms in the proportion with the event, cec_{e} is the cost per event in GBP and qeq_{e} is the QALY loss per event.

The event adds GBP 1,455 per QALY, about 6%. For a decision near GBP 25,000 per QALY that could change the conclusion, so the omission fails the criterion and the event enters the conceptual model before coding. Had the event rate been equal in both arms, Δp\Delta p would be zero and incremental results would not change, in line with the CADTH note that an outcome occurring equally among technologies may be excluded with little effect. The clinicians' agreement is reported under AdViSHE item A1, while agreement with observed outcomes belongs to External Validation.

Other names for the check and terms that clash

Wright and colleagues use descriptive validity, which Hammerschmidt and colleagues credit to McCabe and Dixon, for whether a simplified structure still adequately represents the natural history of the disease or the pathways of care, and note that AdViSHE treats it as conceptual validation. Vemer and colleagues report that conceptual model validation is sometimes called content validity, a psychometric term for whether a measure covers all facets of a construct, as on the content validity page. The page on structural validity of a measurement instrument likewise belongs to questionnaires, not model design.

Limits and common misreadings

Sensitivity analysis is sometimes mistaken for validation. Abraham and colleagues found one-way and probabilistic analyses still presented as validation of the conceptual model and inputs, though such analyses show uncertainty in outcomes and are not meant to test validity. Both vary parameters within a fixed structure, so neither can show whether that structure suits the disease. Simplicity is no exemption either, since de Boer and colleagues argue that choosing a basic decision tree should itself be justified.

Wright and colleagues call the assessment subjective and judged it sufficient only when all their experts agreed the structure was appropriate. A validated structure does not settle structural uncertainty, because several structures may each look reasonable to experts and still give different results. Sargent requires the check to be repeated whenever the model changes.

Sources

  • Abraham K, Corro Ramos I, Braal CL, Feenstra T, Kleijburg A, van Voorn GAK, Uyl-de Groot C. Under-reporting of validation efforts for health economic models persists despite the availability of validation tools: a systematic review. PharmacoEconomics. 2025;43:849-858. https://doi.org/10.1007/s40273-025-01491-2
  • Coyle D, Haines A, Lee K. The development of a model validation tool to assist in the conduct of economic evaluations. Canadian Journal of Health Technologies. 2024;4(3). https://doi.org/10.51731/cjht.2024.862
  • de Boer PT, Frederix GWJ, Feenstra TL, Vemer P. Unremarked or unperformed? Systematic review on reporting of validation efforts of health economic decision models in seasonal influenza and early breast cancer. PharmacoEconomics. 2016;34:833-845. https://doi.org/10.1007/s40273-016-0410-3
  • Eddy DM, Hollingworth W, Caro JJ, Tsevat J, McDonald KM, Wong JB. Model transparency and validation: a report of the ISPOR-SMDM Modeling Good Research Practices Task Force-7. Value in Health. 2012;15(6):843-850. https://doi.org/10.1016/j.jval.2012.04.012
  • Hammerschmidt T, Goertz A, Wagenpfeil S, Neiss A, Wutzler P, Banz K. Validation of health economic models: the example of EVITA. Value in Health. 2003;6(5):551-559. https://doi.org/10.1046/j.1524-4733.2003.65241.x
  • Law AM. How to build valid and credible simulation models. In: Proceedings of the 2019 Winter Simulation Conference. IEEE; 2019:1402-1414. https://www.informs-sim.org/wsc19papers/146.pdf
  • National Institute for Health and Care Excellence. NICE technology appraisal and highly specialised technologies guidance: the manual (PMG36). Published 31 January 2022, last updated 13 October 2026. Sections 4.6.3, 4.6.18 and 4.6.19. https://www.nice.org.uk/process/pmg36
  • Sargent RG. Verification and validation of simulation models. In: Proceedings of the 2011 Winter Simulation Conference. 2011:183-198. https://www.informs-sim.org/wsc11papers/016.pdf
  • Vemer P, Corro Ramos I, van Voorn GAK, Al MJ, Feenstra TL. AdViSHE: a validation-assessment tool of health-economic models for decision makers and model users. PharmacoEconomics. 2016;34(4):349-361. https://doi.org/10.1007/s40273-015-0327-2
  • Wright SJ, Gray E, Rogers G, Donten A, Payne K. A structured process for the validation of a decision-analytic model: application to a cost-effectiveness model for risk-stratified national breast screening. Applied Health Economics and Health Policy. 2024;22:527-542. https://doi.org/10.1007/s40258-024-00887-z

Frequently Asked Questions (6)

  • What is Conceptual Model Validation?

    Conceptual model validation checks that a health economic model's structure, assumptions and pathways fit the disease and the decision problem.

    Source: Coyle et al. 2024

  • Which techniques are used for conceptual model validation of a health economic model?

    Sargent names face validation and traces as the primary techniques for conceptual model validation of a simulation model, and the same approach suits a health economic model. In face validation, experts examine the flowchart or the set of model equations and judge whether the logic and causal relationships are reasonable for the model's purpose. Traces follow entities through each submodel to check that the logic is correct. Sargent also asks for the underlying assumptions to be tested with mathematical analysis and statistical methods on data, and for a check that each theory was applied correctly, such as whether the disease really has the Markov property that a Markov model assumes. The checks are repeated whenever the model changes.

    Source: Sargent 2011

  • What does NICE ask for on conceptual model validation in a technology appraisal submission?

    The NICE technology appraisal manual, NICE PMG36, asks in paragraph 4.6.3 that the conceptual model development process used to choose the model structure be transparent and justified. The submission should give details of expert involvement, such as the number of experts and how they were chosen. Prior use of a structure in published models or earlier NICE submissions is not enough, and the model type and structure should be justified for each new decision problem. Paragraph 4.6.18 asks that models be informed by the natural history of the disease and checked for clinical plausibility, and 4.6.19 that assumptions be validated, when appropriate, by a user of the technology with NHS experience or a user with appropriate expertise.

    Source: NICE PMG36 (2022, updated 2026)

  • What does an HTA reviewer check when assessing conceptual model validation in a submitted model?

    The CADTH model validation tool of Coyle and colleagues sets out the questions in its first seven items. A reviewer checks whether the model reflects the population the decision applies to, can examine important subgroups and includes every comparator in current use. Costs should match the stated perspective, and the model should include all outcomes that clinicians and patients consider important. The structure, meaning the process and clinical pathway, should have been validated by clinical experts and should follow previous models in the area or justify any difference. The tool places this check before verification of the coding, since a technically correct model may still be invalid if the decision problem or the clinical pathway is misspecified.

    Source: Coyle et al. 2024

  • How does conceptual model validation differ from technical verification of a health economic model?

    Conceptual model validation asks whether the model's design represents the disease and the decision problem, while verification checks that the calculations and code correctly implement that design. Eddy and colleagues note that verification does not evaluate the accuracy of a model's structure. Their example is a distance problem set up as a weighted sum of rate and time instead of their product, which can be fitted and coded correctly and still give wrong results over some ranges of rate and time. Verification would not catch such a fault, so the structure needs its own check, which Eddy and colleagues treat under face validity, and comparing model results with observed data can also reveal such a fault.

    Source: Eddy et al. 2012

  • What common mistakes are found in reporting conceptual model validation of health economic models?

    Abraham and colleagues reviewed 78 models of early breast cancer published in 2016 to 2024 and found expert review of the conceptual model reported in 10% (8 of 78) and comparison with the literature in 12% (9 of 78). For the earlier period of 2008 to 2015 the figures were 8% (4 of 48) and 6% (3 of 48), so reporting remained thin. The same review found one-way and probabilistic sensitivity analyses still presented as validation of the conceptual model and inputs. Because such analyses vary parameters within a fixed structure, they cannot show whether the structure suits the disease and are no substitute for expert review of the conceptual model or comparison with earlier models.

    Source: Abraham et al. 2025

Trust Record

Verified by Dr Darrin Baines

British health economist

Professional identity: darrinbaines.org

Verification date: 11 Nov 2026

Content version: 1.0.0

Canonical Identity

Term code
HE-EM-MV-095

Stable URI · Machine-readable · Resolvable · CC BY 4.0

This article is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/concept/conceptual-model-validation