Alternative input data validation compares a health economic model's outcomes with those obtained when its inputs come from other data sources.

Status
Published, version 1.0.0
Last reviewed
12 Nov 2026, by Dr Darrin Baines
Report a problem
Tell us if something is wrong or out of date

Concept Architecture

Alternative Input Data Validation in Health Economic Models

Alternative input data validation tests a health economic model by running it again on inputs taken from a second source and setting the two sets of outcomes side by side. The comparison shows whether the model's costs, life years and QALYs hold up when one credible source replaces another, or whether a single study is carrying the result. Vemer and colleagues list it as item D3 of the AdViSHE tool, one of four checks on model outcomes. NICE treats the same rerun as a sensitivity analysis in health technology assessment, so a reviewer needs to know which reading the modeller intends.

Where the check sits among validation techniques

AdViSHE divides model validation into five parts, covering the conceptual model, input data, the computerised model, operational validation and other techniques. Part D, operational validation, covers techniques used to validate the model outcomes in four items. D1 asks experts to judge the outcomes, D2 compares them with other models, D3 compares them with the outcomes obtained when alternative input data are used, and D4 compares them with empirical data, split into dependent and independent validation.

AdViSHE names two ways of obtaining alternative input data. One uses different literature sources or datasets. The other splits the original data set in two, using one part to calculate the model outcomes and the other to validate against. The tool asks modellers to say where these tests and their outcomes are reported, or why not.

D3 is validation, a check on whether the model gives credible outcomes, and differs from technical verification, which asks whether the model was built as intended. Black-box testing also changes inputs and watches outputs, but the TECH-VER checklist of Büyükkaramikli and colleagues treats it as a verification test of whether model calculations are in line with a priori expectations, for example whether acquisition cost rises with a higher price. Alternative input data validation replaces a base-case source with real, plausible data. Input data validation, AdViSHE Part B, judges whether each source was appropriate in the first place, while D3 looks at what a change of source does to the outcomes.

Rerunning the model on a second source

In the first form, the modeller takes one or more inputs from another credible source, such as utilities from a second valuation study or costs from another registry, runs the model again and compares the outcomes with the base case. Costs, life years and QALYs by arm are more informative than the ICER alone, because a stable ratio can hide changes that offset each other. A reviewer looks for which inputs were replaced, why the second source is credible for the decision population and an explanation of each difference.

De Boer and colleagues reviewed 94 modelling studies of seasonal influenza and early breast cancer published between 2008 and 2014 and found D3 reported in one study, which used all the parameters of a similar study of the same intervention in the same country and compared the results. A test of that kind borders on cross validity, item D2. Eddy and colleagues warn that a high degree of dependency among models, such as using parameters from earlier published models, reduces the value of cross-validation, their term for comparing a model with other models. The same logic applies when the second source shares data with the base case.

Adapting a model to a new setting is a natural point for this test, since Feenstra and colleagues note that reimbursement models are often built for one setting and partially adapted to others, and that reuse still has to come with an assessment of fitness for purpose.

Validating against held-back data

The second form splits one data set, for example a trial arm or registry cohort, into two parts, and parameters are estimated from the first. AdViSHE does not say what the second part is compared with. Read against the wording of D3, the model is run again on parameters from the second part and the two sets of outcomes are compared. If the model's outcomes are compared instead with what was observed in the second part, the test is a comparison with empirical data, item D4, and is what Sargent calls historical data validation, in which part of the data builds the model and the rest tests whether the model behaves as the system does. Statisticians use the related idea of cross-validation to assess the predictive performance of a single fitted model, while the split-sample form of D3 tests the outcomes of a whole decision model.

Eddy and colleagues call a validation dependent when the same source was used both to estimate model parameters and to validate the model, and independent when the model was built without any information from that source. The held-back part has not informed the parameters, yet it shares the study's population and setting, so agreement says less about another population. Eddy and colleagues also advise that the validation plan and sources be chosen before the results are known, which for a split means fixing the split and the acceptance margin in advance.

Validation or sensitivity analysis

NICE PMG36 (2022, updated 2026) treats the choice of data sources as a source of uncertainty. Paragraph 4.7.8 asks that the implications of different key parameter estimates be reflected in sensitivity analyses, for example through alternative data sets. Paragraph 4.7.9 says that when the choice of data sources is not clear, the analysis should be done again using alternative data sources or excluding the doubtful study, for example a study in a network meta-analysis. In NICE's terms the rerun is a sensitivity analysis that tells the committee how much the result depends on the choice of source.

The same rerun is evidence of validity only when it is used to judge the model. Abraham and colleagues found one-way and probabilistic sensitivity analyses still mistaken for validation of the conceptual model and inputs, and point out that a probabilistic sensitivity analysis cannot show whether the source selected for an input is appropriate. De Boer and colleagues note that cost-effectiveness acceptability curves do not evaluate how accurately a model simulates what occurs in reality. On this reading, a rerun becomes a D3 test when the modeller sets out beforehand what the change of source should do to the outcomes and then explains each difference by the way the sources differ, judging whether the new outcomes are still credible for the decision problem. A check of direction alone is closer to TECH-VER black-box testing. Sargent counts sensitivity analysis as a validation technique for simulation models when the model shows the same relationships between inputs and outputs as the real system. PMG36 paragraph 4.6.4 asks for the methods and results of model validation, so such a test can be reported there as well as among the scenario analyses.

Worked example with a split trial arm and a second utility source

All numbers in this example are illustrative. A Markov model with monthly cycles compares a new treatment with standard care in a progressive disease, using progression-free and progressed states.

1. Check progression against held-back patients. The 400 patients in the trial's standard care arm, all followed for two years, are split at random into halves of 200 before any analysis, and the team agrees in advance that the model passes if its two-year progression-free proportion lies within 5 percentage points of the observed one. The estimation half gives a constant monthly probability of progression or death of 0.03.

S24=(1−p)24=0.9724=0.4814S_{24} = (1 - p)^{24} = 0.97^{24} = 0.4814

where S24S_{24} is the modelled proportion alive and progression free after 24 months, pp is the monthly probability of progression or death estimated from the first half and 24 is the number of monthly cycles. In the validation half, 92 of 200 patients were alive and progression free at two years, a proportion of 0.46. The modelled value is 0.4814 minus 0.46, or 2.1 percentage points, above the observed one and inside the agreed margin, though both halves come from one trial population. Because this step compares the model with observed data, it would also be reported under AdViSHE item D4.

2. Rerun with a second utility source. The base case takes utilities of 0.80 progression free and 0.60 progressed from one valuation study, and a second study in the same population gives 0.78 and 0.45. Before rerunning, the modeller expects the larger drop in progressed-state utility to favour the new treatment, which spends less time progressed, so the ICER should fall. Discounted life years and costs do not depend on utilities. The new treatment gives 3.0 discounted life years progression free and 1.5 progressed, standard care gives 2.0 and 2.0, and the incremental cost is GBP 20,000.

Q=LPFuPF+LPDuPDQ = L_{PF} u_{PF} + L_{PD} u_{PD}

where QQ is discounted QALYs per patient, LPFL_{PF} and LPDL_{PD} are discounted life years progression free and progressed, and uPFu_{PF} and uPDu_{PD} are the utilities of those states.

Utility sourceQALYs, new treatmentQALYs, standard careIncremental QALYsICER (GBP per QALY)
Base case, 0.80 and 0.603.0 × 0.80 + 1.5 × 0.60 = 3.3002.0 × 0.80 + 2.0 × 0.60 = 2.8000.50020,000 / 0.500 = 40,000
Second source, 0.78 and 0.453.0 × 0.78 + 1.5 × 0.45 = 3.0152.0 × 0.78 + 2.0 × 0.45 = 2.4600.55520,000 / 0.555 = 36,036

QALYs fall in both arms, by 0.285 for the new treatment and 0.340 for standard care, because the second source values both states lower. Standard care loses more because it spends longer in the progressed state, so incremental QALYs rise by 0.055 and the ICER falls by about 10%, in the predicted direction. Which utility set belongs in the base case remains an input data question, settled by how well each source fits the decision population.

Limits and common misreadings

Abraham and colleagues found that none of 78 early breast cancer model studies published between 2016 and 2024 reported validation with alternative input data, and none of 48 such studies published between 2008 and 2015 had done so. The single D3 study in the review by de Boer and colleagues concerned influenza vaccination. This item and validation of the computerised model were the least reported categories, each under 4%. Four misreadings are common.

  1. Reading a scenario analysis as validation. A rerun reported only as a change in the ICER describes uncertainty and says nothing about whether the model is right.
  2. Reading agreement between dependent sources as confirmation. Sources that share a trial, or copy the parameters of an earlier model, agree for that reason alone.
  3. Reading disagreement as model failure. Outcomes may differ because populations differ, and PMG36 paragraph 4.6.15 asks that the choice of data sets be justified by their suitability to the population of interest.
  4. Adjusting the model until the outcomes agree. Eddy and colleagues say a model ready for external validation should not be modified further to fit a particular data source.

Sources

  • Abraham K, Corro Ramos I, Braal CL, Feenstra T, Kleijburg A, van Voorn GAK, Uyl-de Groot C. Under-reporting of validation efforts for health economic models persists despite the availability of validation tools: a systematic review. PharmacoEconomics. 2025;43:849-858. https://doi.org/10.1007/s40273-025-01491-2
  • Büyükkaramikli NC, Rutten-van Mölken MPMH, Severens JL, Al M. TECH-VER: a verification checklist to reduce errors in models and improve their credibility. PharmacoEconomics. 2019;37(11):1391-1408. https://doi.org/10.1007/s40273-019-00844-y
  • de Boer PT, Frederix GWJ, Feenstra TL, Vemer P. Unremarked or unperformed? Systematic review on reporting of validation efforts of health economic decision models in seasonal influenza and early breast cancer. PharmacoEconomics. 2016;34:833-845. https://doi.org/10.1007/s40273-016-0410-3
  • Eddy DM, Hollingworth W, Caro JJ, Tsevat J, McDonald KM, Wong JB. Model transparency and validation: a report of the ISPOR-SMDM Modeling Good Research Practices Task Force-7. Value in Health. 2012;15(6):843-850. https://doi.org/10.1016/j.jval.2012.04.012
  • Feenstra T, Corro-Ramos I, Hamerlijnck D, van Voorn G, Ghabri S. Four aspects affecting health economic decision models and their validation. PharmacoEconomics. 2022;40:241-248. https://doi.org/10.1007/s40273-021-01110-w
  • National Institute for Health and Care Excellence. NICE technology appraisal and highly specialised technologies guidance: the manual (PMG36). Published 31 January 2022, last updated 13 October 2026. Sections 4.6.4, 4.6.15, 4.7.8 and 4.7.9. https://www.nice.org.uk/process/pmg36
  • Sargent RG. Verification and validation of simulation models. In: Jain S, Creasey RR, Himmelspach J, White KP, Fu M, eds. Proceedings of the 2011 Winter Simulation Conference. IEEE; 2011:183-198. https://www.informs-sim.org/wsc11papers/016.pdf
  • Vemer P, Corro Ramos I, van Voorn GAK, Al MJ, Feenstra TL. AdViSHE: a validation-assessment tool of health-economic models for decision makers and model users. PharmacoEconomics. 2016;34(4):349-361. https://doi.org/10.1007/s40273-015-0327-2

Frequently Asked Questions (6)

  • What is Alternative Input Data Validation?

    Alternative input data validation compares a health economic model's outcomes with those obtained when its inputs come from other data sources.

    Source: Vemer et al. 2016

  • How is alternative input data validation carried out on a health economic model?

    AdViSHE item D3 describes two ways of obtaining the alternative input data. In the first, one or more inputs are taken from different literature sources or datasets, such as utilities from a second valuation study, and the model is run again. In the second, the original data set is split in two, with one part used to calculate the model outcomes and the other used to validate against. The new outcomes are compared with the base case in the first form and with the other part of the data in the second, and each difference is explained. The tool asks modellers to state where these tests and their outcomes are reported, or why not.

    Source: Vemer et al. 2016

  • How does alternative input data validation differ from a sensitivity analysis in a NICE technology appraisal?

    The NICE manual PMG36 treats the choice of data sources as a source of uncertainty. Paragraph 4.7.8 asks that the implications of different key parameter estimates be reflected in sensitivity analyses, for example through alternative data sets, and paragraph 4.7.9 asks for the analysis to be done again with alternative data sources when the choice of sources is not clear. In those terms the rerun shows the committee how far the result depends on the source chosen. Used as validation, the same rerun has a different purpose, which is to judge whether the model outcomes remain credible and to explain each difference by the way the sources differ, and paragraph 4.6.4 asks for the methods and results of model validation.

    Source: NICE PMG36 (2022, updated 2026)

  • What does an HTA reviewer look for when a company submission reports alternative input data validation?

    An HTA reviewer checks which inputs were replaced and why the second source is credible for the decision population. Results by arm for costs and QALYs are more informative than the ICER alone, because a stable ratio can hide changes that offset each other. The reviewer also checks whether the second source is separate from the base case, since Eddy and colleagues warn that a high degree of dependency among models, such as using parameters from earlier published models, reduces the value of cross-validation, by which they mean comparison with other models. Each difference in outcomes should come with an explanation, and a bare change in the ICER describes uncertainty without showing whether the model is right.

    Source: Eddy et al. 2012

  • How often is alternative input data validation reported in published health economic models?

    De Boer and colleagues reviewed 94 modelling studies of seasonal influenza and early breast cancer published between 2008 and 2014 and found this check reported in one study, which used all the parameters of a similar study of the same intervention in the same country. Abraham and colleagues then found that none of 78 early breast cancer model studies published between 2016 and 2024 reported validation with alternative input data. In their review this item and validation of the computerised model were the least reported categories, each under 4% of studies, even though validation tools such as AdViSHE had become available.

    Source: Abraham et al. 2025

  • Which mistakes are common when interpreting alternative input data validation of a health economic model?

    A rerun reported only as a change in the ICER describes uncertainty and says nothing about whether the model is right. Agreement between sources that share a trial, or copy the parameters of an earlier model, can arise for that reason alone, and Eddy and colleagues call a validation dependent when the same source was used both to estimate model parameters and to validate the model. Disagreement need not mean model failure, because outcomes may differ when populations differ. Eddy and colleagues also advise that the validation plan and sources be chosen before the results are known, and that a model ready for external validation should not be modified further to fit a particular data source.

    Source: Eddy et al. 2012

Trust Record

Verified by Dr Darrin Baines

British health economist

Professional identity: darrinbaines.org

Verification date: 12 Nov 2026

Content version: 1.0.0

Canonical Identity

Term code
HE-EM-MV-106

Stable URI · Machine-readable · Resolvable · CC BY 4.0

This article is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/concept/alternative-input-data-validation