TRUST Tool

The TRUST tool is a grid on which HTA analysts record each uncertainty in a health economic model, its source and its likely impact on cost effectiveness.

Status
Published, version 1.0.0
Last reviewed
12 Nov 2026, by Dr Darrin Baines
Report a problem
Tell us if something is wrong or out of date

Concept Architecture

TRUST Tool for Assessing Uncertainty in Health Economic Models

The TRUST tool, short for TRansparent Uncertainty ASsessmenT, is a grid on which an analyst or reviewer records each uncertainty found in a health economic model, the part of the model it affects and whether it stems from transparency, methods or the evidence itself. A second part asks whether each uncertainty is reflected in the probabilistic sensitivity analysis or a scenario analysis, and how far it is likely to move the cost-effectiveness result. Grimm and colleagues, one of them a senior policy adviser of the Dutch Health Care Institute (Zorginstituut Nederland, ZIN), built it for health technology assessment, refined it with feedback from ZIN advisers and other HTA experts, and tested it on Dutch appraisals and one NICE appraisal. It sits beside the model validation tools without being one, because its authors treat uncertainty assessment as a separate but related exercise.

Why HTA needed a systematic uncertainty register

A growing number of technologies obtain marketing authorisation on sparse evidence, such as immature data or single-arm studies, and the models built on that evidence carry uncertainty in their inputs, extrapolations and assumptions. Uncertainty information is usually scattered through the documents, leaving the decision maker to assemble qualitative and quantitative pieces into an overall view of uncertainty and risk.

Grimm and colleagues trace the incomplete characterisation of uncertainty in models to undue emphasis on imprecision, which means doubts about the quality and generalisability of evidence are not always considered, and to the difficulty of expressing every uncertainty as a probability distribution within tight HTA timelines. TRUST concentrates on epistemic uncertainty, which further knowledge could reduce, rather than aleatory uncertainty caused by inherent variability. For one model, TRUST records in one place the uncertainties that the wider uncertainty typology describes.

The grid of model aspects and sources of uncertainty

The first part of TRUST is a matrix whose rows are model aspects, drawn from Walker and colleagues and from UK and Dutch dossier templates, and whose columns are five sources of uncertainty. Combinations judged impossible or unlikely are greyed out, leaving the pattern below.

Model aspectWhat the aspect coversSources left open
Context or scopeThe decision problem as PICOTP (patients, intervention, comparator, outcomes, time horizon, perspective)Transparency, methods, bias and indirectness, unavailability
Model structureThe health states or events and how they relateTransparency, methods, bias and indirectness
Selection of evidenceThe reviews that inform the model inputsTransparency, methods, bias and indirectness, unavailability
Model inputsTransition probabilities or time-to-event or accuracy estimates, relative effectiveness, adverse events, utilities, resource use and costsAll five sources
ImplementationThe technical implementation and the calculationsTransparency, methods
OutcomesThe reported results of the modelTransparency

The five questions, one for each source

Each open cell takes a yes or no answer to the question for its source. A yes turns the cell red and a no turns it green, so the main uncertainties show at a glance, and a not applicable option is available.

  1. Transparency issue. A lack of clarity in presentation, description or justification.
  2. Methodology issue. A violation of best research practices, existing guidelines or the reference case.
  3. Imprecision. Particularly wide confidence intervals, small sample sizes or immature data.
  4. Bias and indirectness. A risk of bias or indirectness in the evidence.
  5. Unavailability. A lack of data or insight.

For questions 2 to 5 the answer intransparent can be chosen when a transparency issue was already recorded. Bias and indirectness gathers the GRADE domains of study limitations, indirectness and publication bias, and also covers structural uncertainty in the ISPOR-SMDM sense. Imprecision corresponds to parameter uncertainty, and unavailability stands for recognised ignorance.

Matching each source to the analysis that addresses it

In TRUST the source of an uncertainty determines the appropriate analysis. Transparency and methods problems are best met early by clarification requests, with unsound analyses redone or explored in scenarios. Imprecision is handled by probabilistic or deterministic sensitivity analysis, bias and indirectness by scenario analysis or expert elicitation when they cannot be parameterised, and unavailability by extreme scenario analysis.

NICE PMG36 (2022, updated 2026) draws a similar division, with uncertainty about structural assumptions in section 4.7.3, reference-case methods in section 4.7.7, the choice of data sources in section 4.7.8 and parameter precision in section 4.7.10.

Judging the impact on cost effectiveness

The second part of TRUST asks whether each recorded uncertainty is appropriately reflected in the probabilistic analysis, and hence in the expected value of perfect information, and whether it is explored in a scenario analysis. It then asks for the impact on cost effectiveness, answered as likely high impact, likely low impact, likely no impact or unknown, with likely high impact and unknown shown in red.

Where neither analysis is available a subjective judgement has to be made, and the authors argue that an explicit judgement beats an implicit one. When parameterising is infeasible they propose reporting ranges of the incremental cost-effectiveness ratio or of net benefit, with plausible and extreme scenarios.

Grimm and colleagues place TRUST in a three-phase process. In phase I the analyst or reviewer identifies uncertainties, phase II explores their impact on cost effectiveness and then on risk, and in phase III the decision maker appraises the risk and chooses any risk-management option, such as a managed entry agreement. TRUST covers phase I and the cost-effectiveness step of phase II.

TRUST beside verification and validation

Verification asks whether a model was built right, and validation asks whether it is the right model for the decision. TRUST is not designed to answer either question. Its authors call uncertainty assessment a separate albeit related exercise to validation, note that a rigorously validated model will still suffer from uncertainty, and caution against assuming that uncertainty is resolved once validation has taken place.

Corro Ramos and colleagues point out that sensitivity analysis explores uncertainty and does not validate a model, since a model full of errors may still give stable results. In simulation science, Sargent lists parameter variability and sensitivity analysis among validation techniques, used to check that a model's outputs respond to parameter changes in the same way as the real system. A TRUST grid with every cell green does not show that the model calculates correctly, which is the work of technical verification and checklists such as TECH-VER. The implementation row records only transparency and methods problems a reviewer notices, such as calculations that cannot be traced. Whether the model is the right one belongs to model validation, with validation efforts reported on forms such as AdViSHE.

Even so, Corro Ramos and colleagues cite TRUST among the tools that give structured approaches to aspects of validation. The validation in the title of the 2020 paper means testing the tool itself with stakeholders and case studies, not validating a decision model.

Use in company submissions and external review

TRUST can be completed during model development or review. Five of its seven developers had been active members of a NICE evidence review group, and the tool was tested in five retrospective appraisals of expensive medicines and one ongoing Dutch assessment of tomosynthesis for breast cancer screening. In its NICE case study, pembrolizumab for relapsed or refractory classical Hodgkin lymphoma, the most influential uncertainties were bias and indirectness, methods and imprecision, not always included in the probabilistic analysis.

NICE PMG36 section 4.7.1 asks for an overall assessment of uncertainty that describes the relative effect of different types of uncertainty on cost-effectiveness estimates and whether the uncertainties that can be included have been adequately captured. PMG36 chapter 4 does not name TRUST. A completed TRUST summary sets out this information by model aspect for an assessment group critiquing a company model.

Worked example with a single-arm cancer submission

All numbers in this example are illustrative. A company submits a cohort model of Drug X in a relapsed cancer, with effectiveness from a single-arm study compared naively with a historical control. The reviewer completes TRUST and uses the ratio

ICER=C1−C0E1−E0\text{ICER} = \frac{C_1 - C_0}{E_1 - E_0}

where C1C_1 and C0C_0 are the mean discounted costs per patient with Drug X and with the comparator, E1E_1 and E0E_0 are the mean discounted QALYs per patient in each arm, and ICER is the incremental cost-effectiveness ratio in GBP per QALY gained.

1. Base case. The incremental cost is GBP 11,000 and the gain is 0.50 QALYs, so the ICER is 11,000 divided by 0.50, or GBP 22,000 per QALY.

2. Relative effectiveness row. The naive unanchored comparison is marked yes for methods and for bias and indirectness, and neither is in the probabilistic analysis. On request the company supplies a matching-adjusted indirect comparison scenario with an incremental cost of GBP 11,400 and a gain of 0.30 QALYs, so the ICER is 11,400 divided by 0.30, or GBP 38,000 per QALY. The reviewer records likely high impact.

3. Utilities row. Utilities come from a different population, so bias and indirectness is marked yes. A scenario with alternative values gives a gain of 0.48 QALYs at the same GBP 11,000, so the ICER is 11,000 divided by 0.48, or about GBP 22,917 per QALY. The reviewer records likely low impact.

4. Context or scope row. No data exist for one relevant comparator, so unavailability is marked yes and, with no analysis to draw on, impact is unknown, also shown in red.

5. Interpretation. PMG36 section 4.7.15 refers to maximum acceptable ICERs of GBP 25,000 to GBP 35,000 per QALY gained. Comparing the point estimates with that range, the base case and the utility scenario stay below GBP 25,000, while the indirect comparison scenario lies above GBP 35,000, so among the quantified rows the decision turns on the relative effectiveness row. The summary passes two red impact cells to the committee, and both concern uncertainty the probabilistic analysis did not capture.

Limits and common misreadings

The developers reported the main weaknesses themselves from interviews and case studies. Most concern judgement and time rather than the structure of the grid.

No uncertainty score. The first version had a GRADE-inspired scoring system, dropped after large inter-rater variability, long completion times and the risk that users would mistake the score for a quantitative weight.

Subjective impact judgements. The impact column may elicit subjective answers when no probabilistic or scenario analysis covers an uncertainty.

Time. The case studies suggested about one hour when the dossier and model were already known, and longer when uncertainty information was hard to find. Failing to complete TRUST within a review is itself worth reporting.

Setting. The tool was built for UK and Dutch decision making, and the authors advise against changing its sources of uncertainty without good justification.

Not a validation result. A completed grid shows where a model is uncertain, not whether it was built correctly or represents the decision problem. It complements the decision uncertainty estimate from the probabilistic analysis.

Sources

  • Corro Ramos I, Feenstra T, Ghabri S, Al M. Evaluating the validation process: embracing complexity and transparency in health economic modelling. PharmacoEconomics. 2024;42:715-719. https://doi.org/10.1007/s40273-024-01364-0
  • Grimm SE, Pouwels X, Ramaekers BLT, Wijnen B, Knies S, Grutters J, Joore MA. Development and validation of the TRansparent Uncertainty ASsessmenT (TRUST) tool for assessing uncertainties in health economic decision models. PharmacoEconomics. 2020;38:205-216. https://doi.org/10.1007/s40273-019-00855-9
  • National Institute for Health and Care Excellence. NICE technology appraisal and highly specialised technologies guidance: the manual (PMG36). Chapter 4, Economic evaluation. Published 31 January 2022, last updated 13 October 2026. https://www.nice.org.uk/process/pmg36/chapter/economic-evaluation-2
  • Sargent RG. Verification and validation of simulation models. In: Proceedings of the 2011 Winter Simulation Conference. 2011:183-198. https://www.informs-sim.org/wsc11papers/016.pdf

Frequently Asked Questions (6)

  • What is TRUST Tool?

    The TRUST tool is a grid on which HTA analysts record each uncertainty in a health economic model, its source and its likely impact on cost effectiveness.

    Source: Grimm et al. 2020

  • How is the TRUST tool completed for a health economic model?

    The analyst or reviewer works through a grid whose rows are model aspects, namely context or scope, model structure, selection of evidence, model inputs, implementation and outcomes, and whose columns are five sources of uncertainty. Each open cell answers one yes or no question for its source, whether transparency, methodology, imprecision, bias and indirectness, or unavailability, and a yes turns the cell red so the main uncertainties show at a glance. A second part asks whether each recorded uncertainty is reflected in the probabilistic sensitivity analysis or explored in a scenario analysis. Grimm and colleagues then ask for its likely impact on cost effectiveness, recorded as likely high impact, likely low impact, likely no impact or unknown.

    Source: Grimm et al. 2020

  • How can the TRUST tool help an HTA reviewer such as a NICE External Assessment Group critique a company model?

    Section 4.7.1 of NICE PMG36 (2022, updated 2026) asks for an overall assessment of uncertainty that describes the relative effect of different types of uncertainty on cost-effectiveness estimates and whether the uncertainties that can be included in the analyses have been adequately captured. The manual does not name the TRUST tool, but a completed TRUST summary sets out this information by model aspect for a group critiquing a company model. Its question on whether each uncertainty is reflected in the probabilistic analysis matches the adequacy point, and its impact column matches the relative effect. The manual also treats uncertainty about structural assumptions, reference-case methods, data sources and parameter precision separately in sections 4.7.3, 4.7.7, 4.7.8 and 4.7.10.

    Source: NICE PMG36 (2022, updated 2026)

  • Is the TRUST tool a model validation tool for health economic models?

    Corro Ramos and colleagues cite TRUST among the tools that give structured approaches to aspects of model validation, while its developers call uncertainty assessment a separate albeit related exercise to validation. The same authors also point out that sensitivity analysis explores uncertainty and does not validate a model, since a model full of errors may still give stable results. A TRUST grid with every cell green does not show that the model calculates correctly, which is the work of technical verification, or that it is the right model for the decision, which is the work of validation. The word validation in the title of the 2020 TRUST paper refers to testing the tool itself.

    Source: Corro Ramos et al. 2024; Grimm et al. 2020

  • How does the TRUST tool match each source of uncertainty in a health economic model to the analysis that should address it?

    Transparency and methods problems are best met early by clarification requests, with analyses that were not methodologically sound redone or explored in scenarios. Imprecision is handled by probabilistic or deterministic sensitivity analysis, while bias and indirectness can be explored through scenario analysis or expert elicitation when they cannot be parameterised. Unavailability of data, which Grimm and colleagues treat as recognised ignorance, calls for extreme scenario analysis. Where neither a probabilistic nor a scenario analysis covers an uncertainty, the authors argue that an explicit subjective judgement of its impact on cost effectiveness is better than an implicit one, and they suggest reporting ranges of the ICER or net benefit.

    Source: Grimm et al. 2020

  • What are the limitations of the TRUST tool in HTA model review?

    The developers dropped a GRADE-inspired scoring system from the first version after large inter-rater variability, long completion times and the risk that users would mistake the score for a quantitative weight, so the grid gives no overall uncertainty score. The impact column may elicit subjective answers when no probabilistic or scenario analysis covers an uncertainty. In the case studies the tool took about one hour when the dossier and model were already known, and longer when uncertainty information was hard to find. It was built for UK and Dutch decision making, and a completed grid shows where a model is uncertain without showing whether it was built correctly.

    Source: Grimm et al. 2020

Trust Record

Verified by Dr Darrin Baines

British health economist

Professional identity: darrinbaines.org

Verification date: 12 Nov 2026

Content version: 1.0.0

Canonical Identity

Term code
HE-EM-MV-119

Stable URI · Machine-readable · Resolvable · CC BY 4.0

This article is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/concept/trust-tool