Multi-Application Model

A multi-application model is a health economic model reused for many decision problems in one disease, so it needs validating in general and for each use.

Status
Published, version 1.0.0
Last reviewed
12 Nov 2026, by Dr Darrin Baines
Report a problem
Tell us if something is wrong or out of date

Concept Architecture

Multi-Application Model in Health Economic Evaluation

Many health economic models answer one question and are then set aside, but some are kept, updated and run again each time a new intervention in the same disease needs assessing. The ISPOR-SMDM task force on transparency and validation calls these general or multiapplication models, citing an HIV model used repeatedly for different questions about HIV. Reuse saves effort and keeps comparisons across decisions consistent, yet a model that was accurate for its first application can fall out of date as evidence changes, or be stretched to populations it was never tested on. For health technology assessment bodies the practical question is whether the version submitted has been validated for the decision at hand, and an earlier validation of the same model answers that only in part.

General and application-specific validity

Eddy and colleagues separate two layers of validation. A multi-application model can be validated in a general sense, as a diabetes model or a heart disease model, and for a specific application, such as the effect of a drug on glycaemia in diabetes. A single-application model needs only the second layer.

The task force adds that validity cannot be declared once for all uses. A model can have different levels of validity for different applications, the accuracy required depends on the question, and multi-application models should change over time to keep up with new science and evidence. Every type of validation should therefore be carried out in the context of specific applications, and validation reports should name the intended applications. In the report's account the descriptions and validations of the general model are updated as the science and the model evolve, and each instantiation is described, validated and reported as each application is done.

Simulation science reaches the same position. Sargent's procedure schedules periodic review of validity for a model used over a period of time and asks for a procedure to review the validity of repeated-use models over their life cycles. In his example, a model first validated without system data should be revalidated before each use whenever new data or understanding has appeared since the last validation. He also notes that a model may be valid for one set of experimental conditions and invalid for another, the idea behind the entry Domain of Applicability.

Names for the same idea

Feenstra and colleagues write that the reuse of complex models supports the development of multi-use disease models, also called whole disease models or reference models. An expert panel run by a Dutch consortium and reported by Wang and colleagues agreed on the term multi-use disease model and defined it as a health economic decision model that represents the length and dynamics of a disease trajectory, so that it can evaluate a range of current and future interventions and be used repeatedly, possibly after adaptations.

The labels differ in ambition. Tappenden and colleagues frame whole disease modelling as a system-level approach whose boundary captures all relevant aspects of the disease and its treatment, preclinical disease through to death, so that virtually any intervention across the pathway can be evaluated consistently. Afzali and colleagues proposed disease-specific reference models whose structure reflects the natural history of the condition. Wang and colleagues read a reference model as claiming a gold-standard status that a multi-use disease model need not claim, and note that diabetes has more than 10 multi-use models. A reference model in this sense differs from the NICE reference case, which specifies the methods an analysis should follow rather than a shared disease structure.

Evidence adaptation, the transfer of an evaluation or model built for one country to another setting, is a neighbouring idea. Feenstra and colleagues note that reimbursement models are often developed for one setting, such as the UK, and then partially adapted to others, so that authorities may repeatedly assess the same model with small local adaptations.

Revalidation over the life of the model

Best practice VII-8 in the Eddy report asks modellers of multi-application models to describe criteria for determining when validations should be repeated or expanded. External validations need to be redone as an ongoing process when the model is modified or new evidence becomes available, and multi-application models should be validated against as many landmark studies, those experts use as the basis of their understanding of the disease, as possible. Best practice VII-9 asks builders of multiple-use models to seek opportunities for predictive validation, which suits a model expected to remain in service after a study reports.

Verification and validation both recur with each version and answer different questions. After an update, technical verification asks whether the changed code does what the revised specification says and whether unchanged parts still give their earlier results, a check usually called regression testing. Model validation asks whether the revised model still agrees with expert understanding and observed data, through face validity review, external validation and cross validity comparisons with other models of the same decision problem.

Kent and colleagues, writing about diabetes, where most models are designed for multiple applications, propose that modellers register substantive structural changes that alter the outcomes of the registry's reference-case simulations, that models be provided in defined versions and variants, and that all model versions be encouraged to run pre-defined reference simulations whose results would also show how a model changes over time. In the Wang panel, regular updates and revalidation after updates were the two operational features with the highest priority, each rated highly desirable by more than 80% of respondents.

How reviewers treat a reused model

NICE PMG36 (2022, updated 2026), section 4.6.3, states that it is not enough to say a model structure has previously been used in published reports or accepted in submissions to NICE, and that the type of model and its structure should be justified for each new decision problem. Section 4.6.4 asks for the quality assurance methods used in developing the model and the methods and results of model validation. A reused model therefore earns no exemption. A reviewer such as a NICE External Assessment Group has grounds to ask how the submitted version differs from earlier published versions, which validations were repeated after the changes, and whether the population in the new scope falls inside the range those validations covered.

Feenstra and colleagues argue that reuse makes validation more important, since only models with a generally accepted track record will attract reuse, and that reapplying a model to a new intervention requires renewed validation.

Worked example with a reused diabetes model

All numbers in this example are illustrative. A research group maintains a type 2 diabetes model. Its validation plan, written in line with VII-8, sets two triggers. A change of more than 2% in any reference simulation output between versions triggers repeat external validation of the component behind the change, and any structural change triggers full revalidation.

Δ=Vn−VoVo×100\Delta = \frac{V_{n} - V_{o}}{V_{o}} \times 100

where Δ\Delta is the percentage change, VnV_{n} is the output of the new version and VoV_{o} is the output of the old version for the same reference simulation.

1. Update and reference simulation. Version 3.1 replaces the background mortality tables of version 3.0 and leaves every other component unchanged. For a reference patient aged 60, undiscounted life expectancy rises from 18.40 to 18.95 years, a change of 0.55 divided by 18.40, or 2.99%. Undiscounted QALYs rise from 12.60 to 12.93, a change of 0.33 divided by 12.60, or 2.62%. Ten-year cumulative incidence of myocardial infarction moves from 12.0% to 12.1%, a change of 0.1 divided by 12.0, or 0.83%.

2. Trigger. Life expectancy and QALYs move by more than 2%, so the mortality component is externally validated again. Myocardial infarction incidence stays inside the trigger, as expected when only background mortality has changed.

3. Repeat external validation. In a landmark cohort that did not supply the new mortality tables, observed ten-year all-cause mortality is 21.0%. Version 3.0 predicted 23.5%, a difference of 2.5 divided by 21.0, or 11.90%. Version 3.1 predicts 21.6%, a difference of 0.6 divided by 21.0, or 2.86%.

4. New application. The group is then asked to evaluate a new drug for people over 75 with chronic kidney disease. The landmark validations covered mainly younger people without kidney disease, so the general validation does not reach this population. Application-specific validation against a published cohort in that group comes before any cost-effectiveness results, and the report states where data are lacking.

5. Reading the result. Version 3.1 agrees more closely with observed mortality than version 3.0, yet that gives no direct assurance for the new population, so the submission should report the version used, the changes since the last validation and the application-specific checks.

Limitations and common misreadings

Jin and colleagues identified 44 whole disease models, 32 of them developed after 2010, and judged their quality generally low, so that many may need significant modification before reuse. Four misreadings recur.

  1. Treating a past validation as permanent. Eddy and colleagues reject the idea that validity is a property of a model that applies to all its applications for all time.
  2. Assuming broad scope means broad validity. A model spanning the whole pathway is validated only where its validations reached.
  3. Refitting the model to each validation source. Eddy and colleagues warn that parameters should not be refitted to each validation source to achieve a good match, and that refitting may indicate a different structure is needed.
  4. Ignoring version drift. Results published for an earlier version may not be reproducible with the current one, which is why Kent and colleagues ask for defined versions and variants.

Sources

  • Afzali HH, Karnon J, Merlin T. Improving the accuracy and comparability of model-based economic evaluations of health technologies for reimbursement decisions: a methodological framework for the development of reference models. Medical Decision Making. 2013;33(3):325-332. https://doi.org/10.1177/0272989X12458160
  • Eddy DM, Hollingworth W, Caro JJ, Tsevat J, McDonald KM, Wong JB. Model transparency and validation: a report of the ISPOR-SMDM Modeling Good Research Practices Task Force-7. Value in Health. 2012;15(6):843-850. https://doi.org/10.1016/j.jval.2012.04.012
  • Feenstra T, Corro-Ramos I, Hamerlijnck D, van Voorn G, Ghabri S. Four aspects affecting health economic decision models and their validation. PharmacoEconomics. 2022;40:241-248. https://doi.org/10.1007/s40273-021-01110-w
  • Jin H, Tappenden P, Ling X, Robinson S, Byford S. A systematic review of whole disease models for informing healthcare resource allocation decisions. PLoS One. 2023;18(9):e0291366. https://doi.org/10.1371/journal.pone.0291366
  • Kent S, Becker F, Feenstra T, et al. The challenge of transparency and validation in health economic decision modelling: a view from Mount Hood. PharmacoEconomics. 2019;37(11):1305-1312. https://doi.org/10.1007/s40273-019-00825-1
  • National Institute for Health and Care Excellence. NICE technology appraisal and highly specialised technologies guidance: the manual (PMG36). Published 31 January 2022, last updated 13 October 2026. Sections 4.6.3 and 4.6.4. https://www.nice.org.uk/process/pmg36
  • Sargent RG. Verification and validation of simulation models. In: Proceedings of the 2011 Winter Simulation Conference. 2011:183-198. https://www.informs-sim.org/wsc11papers/016.pdf
  • Tappenden P, Chilcott J, Brennan A, Squires H, Stevenson M. Whole disease modeling to inform resource allocation decisions in cancer: a methodological framework. Value in Health. 2012;15(8):1127-1136. https://doi.org/10.1016/j.jval.2012.07.008
  • Wang J, Pouwels X, Ramaekers B, et al. A blueprint for multi-use disease modeling in health economics: results from two expert-panel consultations. PharmacoEconomics. 2024;42(7):797-810. https://doi.org/10.1007/s40273-024-01376-w

Frequently Asked Questions (6)

  • What is Multi-Application Model?

    A multi-application model is a health economic model reused for many decision problems in one disease, so it needs validating in general and for each use.

    Source: Eddy et al. 2012

  • How is a multi-application model validated compared with a single-application model?

    The ISPOR-SMDM task force on transparency and validation separates two layers of validation for a multi-application model. The model can be validated in a general sense, as a diabetes model or a heart disease model, and again for a specific application, such as the effect of a drug on glycaemia. A single-application model needs only the second layer. The task force also asks that every type of validation be carried out in the context of specific applications and that validation reports name the intended applications, because one model can have different levels of validity for different uses.

    Source: Eddy et al. 2012

  • When should a multi-application model be revalidated?

    Sargent's recommended validation procedure treats revalidation as a planned task for a model kept in service. He recommends a schedule for periodic review of validity when a model is used over a period of time, and a procedure for reviewing the validity of repeated-use models over their life cycles. In his example, a model first validated without system data should be revalidated before each use whenever new data or new understanding of the system has appeared since the last validation. He also notes that a model may be valid for one set of experimental conditions and invalid for another, so a health economic model reused for a new population needs checking for that population.

    Source: Sargent 2011

  • Does NICE accept a multi-application model because it was used in earlier submissions?

    Earlier use gives a multi-application model no exemption in a NICE appraisal. NICE PMG36, section 4.6.3, states that it is not enough to say a model structure has previously been used in published model reports or accepted in submissions to NICE, and that the type of model and its structure should be justified for each new decision problem. Section 4.6.4 asks the company to detail the quality assurance methods used in developing the model and to provide the methods and results of model validation.

    Source: NICE PMG36 (2022, updated 2026)

  • What should an HTA reviewer look for when a submission uses a multi-application model?

    A reviewer such as a NICE External Assessment Group needs to know which version of the multi-application model was submitted and how it differs from earlier published versions. The ISPOR-SMDM task force asks modellers of such models to describe criteria for deciding when validations should be repeated or expanded, and says external validations need to be redone as an ongoing process when the model is modified or new evidence appears. A reviewer can therefore ask which validations were repeated after the latest changes. Since each instantiation should be validated and reported as each application is done, the reviewer can also check whether the population in the new scope falls inside the range that earlier validations covered.

    Source: Eddy et al. 2012

  • How does a multi-application model differ from a reference model?

    Both labels describe a disease model meant for reuse, but they claim different things. An expert panel run by a Dutch consortium and reported by Wang and colleagues agreed on the term multi-use disease model, meaning a health economic decision model that represents the length and dynamics of a disease trajectory, so that it can evaluate a range of current and future interventions and be used repeatedly, possibly after adaptations. Wang and colleagues read a reference model as claiming a gold-standard status that a multi-use disease model need not claim. Several multi-use models can coexist in one disease, and they note that diabetes has more than 10.

    Source: Wang et al. 2024

Trust Record

Verified by Dr Darrin Baines

British health economist

Professional identity: darrinbaines.org

Verification date: 12 Nov 2026

Content version: 1.0.0

Canonical Identity

Term code
HE-EM-MV-130

Stable URI · Machine-readable · Resolvable · CC BY 4.0

This article is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/concept/multi-application-model