Concept Architecture

ISPOR-SMDM Modeling Good Research Practices for Health Economic Models

The ISPOR-SMDM Modeling Good Research Practices are the recommendations of a joint task force of ISPOR and the Society for Medical Decision Making, published in 2012 as seven reports on how decision models in health care should be built, analysed and judged. The series updated the first ISPOR modelling task force report of 2003, and each report appeared in both Value in Health and Medical Decision Making. For model validation the seventh report, on model transparency and validation, matters most, and Corro Ramos and colleagues credit it with establishing a framework for conducting validation of health economic models.

How the joint task force produced the seven reports

The ISPOR Board of Directors approved a new modelling task force in 2010 and invited the Society for Medical Decision Making to join. After a meeting in Boston in March 2011, draft recommendations went to members as a survey in which each agreed or disagreed with each recommendation. Final drafts were posted on both societies' websites for comment, and a second group of experts formally reviewed the articles.

ReportTopicFirst author
Task Force-1Overview and all recommendationsCaro
Task Force-2Conceptualising a modelRoberts
Task Force-3State-transition modellingSiebert
Task Force-4Discrete event simulationKarnon
Task Force-5Dynamic transmission modellingPitman
Task Force-6Parameter estimation and uncertaintyBriggs
Task Force-7Model transparency and validationEddy

Reports 3 to 5 each cover one model type, the state transition model, discrete event simulation and the dynamic transmission model. Report 6 separates stochastic uncertainty, parameter uncertainty and heterogeneity, treats structural uncertainty as a further level, and links parameter uncertainty to decision uncertainty.

The nine best practices of Task Force-7

Task Force-7 names transparency and validation as the two main ways modellers build confidence in a model's results. Its authors expect every model to be able to meet the transparency practices, accept that not every model will meet all the validation practices, and describe optimal practices to strive toward in place of minimum quality standards. The nine practices are numbered VII-1 to VII-9.

NumberAreaWhat the practice asks
VII-1TransparencyFreely accessible non-technical documentation of model type, intended applications, funding, structure, inputs and outputs, data sources, validation methods and results, and limitations
VII-2TransparencyTechnical documentation detailed enough for an expert reader to evaluate and potentially reproduce the model, released openly or under intellectual property agreements at the modellers' discretion
VII-3Face validityEvaluation of structure, evidence, problem formulation and results by impartial experts, preferably blinded to the results, with the process described on request
VII-4VerificationRigorous verification, with methods described in the non-technical documentation and pertinent results available on request
VII-5Cross validityA search for modelling analyses of the same or similar problems and discussion of their similarities and differences
VII-6External validationA formal process that identifies and justifies data sources, labels each as dependent, partially dependent or independent, states which model parts each source evaluates, simulates each source and compares results quantitatively
VII-7External validationA description of the validation process and results on request, the model parts that cannot be validated and how uncertainty about them was addressed
VII-8Multi-application modelsCriteria for when validations are repeated or expanded
VII-9Predictive validationWhen feasible, a test of the model's prediction of future events

Verification and validation in the Task Force-7 scheme

The report describes five types of validation, face validity, verification or internal validity, cross validity, external validity and predictive validity, and calls the last two the strongest. Sargent, writing for simulation science, defines verification separately from validation and uses internal validity for the stochastic variability across replications of a model, a different sense from the report's. Verification asks whether the model was built right, meaning whether its calculations are performed correctly and are consistent with its specification, the subject of the technical verification page. Its techniques, each with its own entry, include structured walkthroughs, double programming, hand calculations, extreme value analysis and trace analysis.

The other four types ask whether the model is the right one for the decision. The report warns that verification cannot detect a poorly chosen structure, since parameters can be estimated well and equations coded correctly in a model that still predicts badly.

Two principles shape the report. Validity belongs to an application, so no criteria can declare a model valid for all uses, and far less accuracy is needed to say whether an intervention raises or lowers costs than to say how much it costs. Sensitivity analysis is a complement to validation and not a substitute, because varying inputs does not show how accurately a model simulates reality.

A validation is dependent when the same source was used to estimate parameters and to validate, partially dependent when the source was used to build or calibrate part of the model but that part does not by itself determine the outcome being validated, and independent when the source contributed nothing to building the model. Dependent validations are closely related to calibration, whose reporting should state the target, goodness-of-fit metric, search algorithm, acceptance criteria and stopping rule. The report's cross-validation means comparing models with each other, which differs from the statistical resampling method on the cross-validation page.

How reviewers and HTA agencies use the reports

Ghabri and colleagues restate the Task Force-7 types as five questions about a submitted model and note that health technology assessment guidelines reference these questions without providing a practical framework for answering them, while Australian and Dutch guidelines ask applicants for structured reporting of validation tests, for example with AdViSHE. NICE PMG36 (2022, updated 2026) section 4.6.4 asks companies to detail the quality assurance methods used in developing the model and to provide the methods and results of model validation. Sections 4.6.18 to 4.6.20 ask for checks of clinical plausibility, for assumptions to be validated by a user with appropriate expertise, and for the external validity of extrapolation to be judged against data such as historical cohorts. The economic evaluation chapter of PMG36 does not name the ISPOR-SMDM reports.

AdViSHE assumes that a model was built to prevailing guidelines such as the ISPOR-SMDM practices, while choosing its own terms in place of the Task Force-7 classification. The Mount Hood diabetes modelling network, following the ISPOR-SMDM guidelines, asks modelling groups for technical and non-technical documentation sufficient to enable reproduction, without requiring model code. Ghabri and colleagues report a NICE single technology appraisal of azacitidine for acute myeloid leukaemia in which the company's ICER of about GBP 21,000 per QALY gained rose to about GBP 63,000 once undisputed errors in the model were corrected.

Worked example applying VII-6 to a registry comparison

All numbers in this example are illustrative. The standard-care arm of a company model for a new cancer drug is checked against a national registry of patients on standard care that played no part in building the model, so under VII-6 the comparison is labelled independent. As the report advises, the simulation matches the registry's population and treatment, and outcomes are compared at the registry's own follow-up times. The reviewer reports the share of comparisons within a pre-set bound, a summary the report allows, and sets that bound at a relative difference of 0.10.

p=1K∑k=1KI(∣y^k−yk∣yk≤b)p = \frac{1}{K} \sum_{k=1}^{K} I\left( \frac{|\hat{y}_k - y_k|}{y_k} \le b \right)

where pp is the proportion of comparisons within the bound, KK is the number of comparisons, y^k\hat{y}_k is the modelled proportion for comparison kk, yky_k is the observed proportion, bb is the bound and II equals 1 when the condition holds and 0 otherwise.

OutcomeModelledObservedRelative differenceWithin 0.10
Overall survival, 1 year0.820.800.02 / 0.80 = 0.025Yes
Overall survival, 3 years0.540.500.04 / 0.50 = 0.080Yes
Overall survival, 5 years0.360.300.06 / 0.30 = 0.200No
Progression-free, 1 year0.610.580.03 / 0.58 = 0.052Yes
Progression-free, 2 years0.380.400.02 / 0.40 = 0.050Yes
Progression-free, 3 years0.220.260.04 / 0.26 = 0.154No

Four of the six comparisons fall within the bound, so p=4/6=0.667p = 4 / 6 = 0.667, or 66.7%. Both misses lie in the later years but point in opposite directions, with five-year overall survival overstated by 0.06 and three-year progression-free survival understated by 0.04. At three years the modelled share alive after progression, overall survival less progression-free survival, is 0.32 (0.54 less 0.22) against 0.24 observed (0.50 less 0.26), so the model keeps too many patients alive after progression, which suggests an optimistic overall survival tail and a pessimistic progression-free tail. Under VII-6 the discrepancies and the sensitivity analyses run on them are reported, and Task Force-7 advises against refitting parameters to each source to force a match. A reviewer would run a justified alternative extrapolation as a scenario analysis, which PMG36 section 4.6.20 asks to be considered routinely, and would treat any later comparison with the registry as dependent once the registry has been used to choose the curve.

Limits and common misreadings

Optimal practices with no pass mark. Task Force-7 states that a model unable to meet every practice is not necessarily without use. Corro Ramos and colleagues take a firmer line and treat the Task Force-7 framework and AdViSHE as minimum validation standards for model-based studies.

Accuracy as the aim is contested. The report defines validation as a set of methods for judging a model's accuracy in making relevant predictions. Kent and colleagues record the counter-view that a focus on accuracy is misplaced given the uncertainty in health economic modelling, and that the test is whether a model is a proper and sufficient representation of the system, the definition AdViSHE adopts.

Transparency is not validity. The report notes that a model can be transparent and still give the wrong answer, and that a model most readers cannot follow can still be correct. Citing the reports does not show a model is valid, since the practices set no criteria for validity.

Sources

  • Briggs AH, Weinstein MC, Fenwick EA, Karnon J, Sculpher MJ, Paltiel AD. Model parameter estimation and uncertainty: a report of the ISPOR-SMDM Modeling Good Research Practices Task Force-6. Value in Health. 2012;15(6):835-842. https://doi.org/10.1016/j.jval.2012.04.014
  • Caro JJ, Briggs AH, Siebert U, Kuntz KM. Modeling good research practices, overview: a report of the ISPOR-SMDM Modeling Good Research Practices Task Force-1. Value in Health. 2012;15(6):796-803. https://doi.org/10.1016/j.jval.2012.06.012
  • Corro Ramos I, Feenstra T, Ghabri S, Al M. Evaluating the validation process: embracing complexity and transparency in health economic modelling. PharmacoEconomics. 2024;42:715-719. https://doi.org/10.1007/s40273-024-01364-0
  • Eddy DM, Hollingworth W, Caro JJ, Tsevat J, McDonald KM, Wong JB. Model transparency and validation: a report of the ISPOR-SMDM Modeling Good Research Practices Task Force-7. Value in Health. 2012;15(6):843-850. https://doi.org/10.1016/j.jval.2012.04.012
  • Ghabri S, Stevenson M, Möller J, Caro JJ. Trusting the results of model-based economic analyses: is there a pragmatic validation solution? PharmacoEconomics. 2019;37:1-6. https://doi.org/10.1007/s40273-018-0711-9
  • Kent S, Becker F, Feenstra T, et al. The challenge of transparency and validation in health economic decision modelling: a view from Mount Hood. PharmacoEconomics. 2019;37:1305-1312. https://doi.org/10.1007/s40273-019-00825-1
  • National Institute for Health and Care Excellence. NICE technology appraisal and highly specialised technologies guidance: the manual (PMG36). Chapter 4, Economic evaluation. Published 31 January 2022, last updated 13 October 2026. https://www.nice.org.uk/process/pmg36/chapter/economic-evaluation-2
  • Sargent RG. Verification and validation of simulation models. Proceedings of the 2011 Winter Simulation Conference. 2011:183-198. https://www.informs-sim.org/wsc11papers/016.pdf
  • Vemer P, Corro Ramos I, van Voorn GAK, Al MJ, Feenstra TL. AdViSHE: a validation-assessment tool of health-economic models for decision makers and model users. PharmacoEconomics. 2016;34:349-361. https://doi.org/10.1007/s40273-015-0327-2

Frequently Asked Questions (6)

  • What is ISPOR-SMDM Modeling Good Research Practices?

    ISPOR-SMDM Modeling Good Research Practices are seven 2012 task force reports giving best practice for building and validating health economic models.

    Source: Eddy et al. 2012

  • What topics do the seven ISPOR-SMDM Modeling Good Research Practices reports cover?

    A joint task force of ISPOR and the Society for Medical Decision Making published the seven reports in 2012, each in both Value in Health and Medical Decision Making. The first gives an overview of the series and the second deals with conceptualising a model. Reports three to five each take one model type, namely state-transition models, discrete event simulation and dynamic transmission models, while the sixth covers parameter estimation and uncertainty. The seventh, by Eddy and colleagues, covers model transparency and validation and matters most for model validation. The ISPOR Board of Directors approved the task force in 2010 and invited the Society for Medical Decision Making to join.

    Source: Eddy et al. 2012

  • What are the nine best practices in the Task Force-7 report of the ISPOR-SMDM Modeling Good Research Practices?

    Eddy and colleagues number them VII-1 to VII-9 and expect every model to be able to meet the two transparency practices, which ask for freely accessible non-technical documentation and for technical documentation detailed enough for an expert to evaluate and potentially reproduce the model. VII-3 asks for face validity to be judged by impartial experts, VII-4 for rigorous verification, and VII-5 for a search for other models of the same problem with a discussion of how their results differ. VII-6 and VII-7 set out a formal external validation process and what is made available on request. VII-8 covers repeated validation of multi-application models and VII-9 asks for predictive validation when feasible.

    Source: Eddy et al. 2012

  • How do HTA reviewers use the ISPOR-SMDM Modeling Good Research Practices when assessing a submitted model?

    Ghabri and colleagues restate the Task Force-7 validation types as five questions that can be asked of a submitted model, covering face validity, verification, cross validity, external validity and predictive validity. They note that health technology assessment guidelines reference these questions without providing a practical framework for answering them. The same authors describe a NICE single technology appraisal of azacitidine for acute myeloid leukaemia in which the company's ICER of about GBP 21,000 per QALY gained rose to about GBP 63,000 once undisputed errors in the model were corrected. Ghabri and colleagues also note that Australian and Dutch guidelines go further and ask applicants for structured reporting of validation tests, for example with AdViSHE.

    Source: Ghabri et al. 2019

  • Does NICE require companies to follow the ISPOR-SMDM Modeling Good Research Practices in a technology appraisal?

    The economic evaluation chapter of the NICE manual PMG36 does not name the ISPOR-SMDM reports, so following them is not a stated NICE requirement. Section 4.6.4 asks companies to detail the quality assurance methods used in developing the model and to provide the methods and results of model validation. Sections 4.6.18 to 4.6.20 ask for checks of clinical plausibility, for assumptions to be validated by a user with appropriate expertise, and for the external validity of extrapolation to be judged against data such as historical cohorts. Section 4.6.20 also asks for alternative extrapolation scenarios to be considered routinely, which shows how far the result depends on the chosen extrapolation without testing the model's accuracy.

    Source: NICE PMG36 (2022, updated 2026)

  • What are the limits of the ISPOR-SMDM Modeling Good Research Practices as a test of model quality?

    Eddy and colleagues describe optimal practices to strive toward in place of minimum quality standards, and state that a model unable to meet every practice is not necessarily without use. The report also notes that a transparent model can still give the wrong answer, so citing the practices does not show that a model is valid. Sensitivity analysis is treated as a complement to validation and never a substitute, because varying inputs does not show how accurately a model simulates reality. Validity belongs to a particular application, and no criteria can declare a model valid for every use.

    Source: Eddy et al. 2012

Trust Record

Verified by Dr Darrin Baines

British health economist

Professional identity: darrinbaines.org

Verification date: 12 Nov 2026

Content version: 1.0.0

Canonical Identity

Term code
HE-EM-MV-115

Stable URI · Machine-readable · Resolvable · CC BY 4.0

This article is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/concept/ispor-smdm-modeling-good-research-practices