Independent verification and validation, or IV&V, means that the checks on a health economic model and the judgement on whether it suits its purpose are made by a party that neither built the model nor paid for it. Technical verification asks whether the model was built right, and model validation asks whether it is the right model for the decision. Independence matters in health technology assessment because a company submitting a reimbursement model has a stake in its result, and a reviewer it pays shares part of that stake. The term comes from simulation science and software engineering, and its nearest health economic form is review of a company model by an independent academic group.
Who decides that a model is valid
Sargent, writing on simulation models in general, describes four ways of deciding whether a model is valid. All four assume that the development team has already verified and validated the model while building it, and they differ in who makes the final decision.
- The development team decides. This is common, and the decision is subjective, based on the team's own tests, though Sargent says one of the next two approaches is usually better.
- Users decide with the team. Where the development team is small, users are closely involved, which shifts the decision towards them and aids credibility.
- A third party decides. This is IV&V, and the third party is independent of both the development team and the model sponsor or user.
- A scoring model decides. Sargent rejects this, partly because a model can reach a passing score and still have a defect.
Sargent says IV&V should be used for large models built by several teams and is also useful for credibility when the problem has a high cost. The third party must understand the model's intended purpose.
Technical, managerial and financial independence
A 1993 report by the US National Research Council on space shuttle flight software judges independence along three dimensions. Each has a counterpart in the review of a reimbursement model.
| Dimension | Meaning in the report | Question for a health economic model |
|---|---|---|
| Technical | Reviewers outside development form their own view of the problem, with their own tools where practical | Did the reviewer test the calculations without relying on the developer's account |
| Managerial | The review sits outside the developers and chooses what to test, how, when and which issues to pursue | Could the reviewer choose which assumptions to examine |
| Financial | The review budget is controlled outside the development organisation | Was the reviewer paid by the company whose product is modelled |
The report calls an arrangement with all three classical IV&V and describes weaker forms. In internal IV&V a separate team inside the developing company does the review, which lowers cost and uses staff who know the system, but loses managerial and financial independence from the customer's point of view. A consultancy hired by a manufacturer to run a verification checklist resembles the report's modified IV&V, in which a separate company does the review but takes its direction and funding from the organisation that also directs development, so the consultancy keeps some technical independence from the modellers but is paid by the sponsor.
Concurrent review and review after completion
Sargent describes two ways of carrying out IV&V. In the concurrent way, which he prefers, the independent team feeds findings to the developers as the model is built, and development does not move to the next stage until the current one has met its verification and validation requirements. In the other way the review starts once the model is finished and can range from evaluating the developers' own verification and validation to a complete new effort. Wood, whose work on energy models Sargent cites, concluded that a complete effort at this point is extremely costly and time consuming for what it yields, and Sargent advises that review of a completed model should usually evaluate only the verification and validation already done.
NICE appraisal is mostly of the second kind. The reviewers see the finished model when NICE sends them the submission (NICE PMG36 section 5.5.11), although the company can discuss the decision problem with them beforehand (section 5.5.3).
Independent review in NICE appraisal
Ghabri and colleagues, one of them a NICE committee member and reviewer, give two reasons why NICE has models verified and validated by an independent group. Submitted models are complex, so construction mistakes are unsurprising, and where two assumptions are equally plausible a company commonly chooses the one more favourable to its product. In single technology appraisals the reviewers critique the company model and amend it where possible, though time limits often leave structural problems flagged but unamended.
NICE PMG36 (2022, updated 2026) calls the reviewer the External Assessment Group (EAG), the role Ghabri and colleagues describe under the name Evidence Review Group. A company submitting a fully executable model must give NICE full access to the programming code (section 5.5.15). The EAG critically evaluates the submission and may amend the company's model in exploratory analyses (section 5.6.15).
The EAG fits IV&V only in part. It is independent of the company, but it reviews the submission for NICE (section 5.5.11), the body that uses the model, and PMG36 refers to economic evaluations produced by EAGs on behalf of NICE (section 4.12.4), whereas Sargent's third party is independent of the user as well. In the National Research Council's classical form, by contrast, the IV&V team is typically a contractor hired by the customer, which is closer to the EAG's position. Corro Ramos and colleagues cite NICE EAGs as external validators without conflicts of interest who give an impartial assessment, while noting that such procedures are costly and do not solve every problem, and they call for more consensus on whether third parties should validate models or whether clear reporting by developers is enough. Ghabri and colleagues suggest that the scarcity of validation among 77 company submissions to the French Haute Autorité de Santé may reflect the time it takes and the need to find external experts without a conflict of interest.
What the independent reviewer needs and reports
An independent reviewer cannot rely on the developer's account, so access comes first. TECH-VER, a verification checklist for health economic models, needs a model reviewer, preferably independent, an executable and transparent model, its input sources and detailed documentation. The ISPOR-SMDM task force report by Eddy and colleagues asks modellers to give full technical documentation and a working copy to readers a journal or decision-making organisation designates, under agreements protecting intellectual property.
For reporting, the AdViSHE tool asks who reviewed the computerised model, why they count as experts, whether they can be qualified as independent and where the results and unresolved issues are reported. On the validation side, Eddy and colleagues suggest that data sources for external validation might be chosen by an independent panel, based on the intended use and not on the chance of success.
A breast screening model validated by Wright and colleagues shows independence of a partial kind. A health economist not involved in the original model rebuilt it in R and found two significant errors, and an analyst external to the core research team, whom the authors call an independent expert, completed TECH-VER, but both were engaged by the research team.
Worked example separating errors from judgement
The numbers are illustrative. A company model for a new cancer treatment against standard care reports an incremental cost of GBP 12,000 and a gain of 0.60 QALYs, assessed at an illustrative threshold of GBP 30,000 per QALY using the incremental net monetary benefit.
where is the threshold in GBP per QALY, is the incremental QALYs and is the incremental cost in GBP.
1. Company base case. The ICER is 12,000 / 0.60 = 20,000 GBP per QALY. The INMB is 30,000 × 0.60 = 18,000, less 12,000, giving GBP 6,000.
2. Verification finding. Tracing costs cycle by cycle shows monitoring costs on the new treatment falling to zero after year 10 while patients are alive, because a cell range ends early. Correcting it raises the incremental cost to GBP 13,500, so the ICER is 13,500 / 0.60 = 22,500 GBP per QALY and the INMB is 18,000 less 13,500, giving GBP 4,500.
3. Validation finding. Modelled 5-year overall survival on standard care is 30%, against 38% in an illustrative registry cohort, so the company's extrapolation understates survival without the new treatment. The reviewer's preferred curve cuts the gain to 0.42 QALYs, with the incremental cost held at GBP 13,500 for simplicity, so the ICER is 13,500 / 0.42 = 32,143 GBP per QALY and the INMB is 30,000 × 0.42 = 12,600, less 13,500, giving minus GBP 900.
4. Reporting. Of the total rise in the ICER of 12,143 GBP per QALY, with the corrections applied in this order, the coding error accounts for 22,500 less 20,000, which is 2,500, and the survival judgement for 32,143 less 22,500, which is 9,643. The reviewer reports them separately, since the coding correction belongs in every scenario, whereas the survival curve is a judgement for the committee.
A careful checker, whether independent of the company or working for it, could find the error in step 2, but step 3 is a choice between plausible assumptions, where a reviewer with no stake in the result is better placed.
Limits and common misreadings
Independent review draws on the same verification and validation techniques as the developers' own checks, but the reviewer chooses which to apply and forms a separate view of the problem. The National Research Council report credits technical independence, a fresh viewpoint, with finding subtle errors that developers' own testing misses.
- Independent validation is a different term. Eddy and colleagues call a validation independent when the model was built without any information from the comparison source, which concerns data, not people. Corro Ramos and colleagues note that the phrase has also been used for validation by a third party.
- Independence is a matter of degree. A report should say which dimensions a reviewer meets.
- A review is no guarantee. Corro Ramos and colleagues state that independent procedures do not solve every problem, and a reviewer under time pressure may flag structural problems without correcting them.
- IV&V does not replace the developer's checks. Sargent's approaches all assume prior verification and validation by the developers, and NICE PMG36 asks companies to detail their quality assurance methods and validation results (section 4.6.4).
Sources
- Büyükkaramikli NC, Rutten-van Mölken MPMH, Severens JL, Al M. TECH-VER: a verification checklist to reduce errors in models and improve their credibility. PharmacoEconomics. 2019;37(11):1391-1408. https://doi.org/10.1007/s40273-019-00844-y
- Corro Ramos I, Feenstra T, Ghabri S, Al M. Evaluating the validation process: embracing complexity and transparency in health economic modelling. PharmacoEconomics. 2024;42:715-719. https://doi.org/10.1007/s40273-024-01364-0
- Eddy DM, Hollingworth W, Caro JJ, Tsevat J, McDonald KM, Wong JB. Model transparency and validation: a report of the ISPOR-SMDM Modeling Good Research Practices Task Force-7. Value in Health. 2012;15(6):843-850. https://doi.org/10.1016/j.jval.2012.04.012
- Ghabri S, Stevenson M, Möller J, Caro JJ. Trusting the results of model-based economic analyses: is there a pragmatic validation solution? PharmacoEconomics. 2019;37(1):1-6. https://doi.org/10.1007/s40273-018-0711-9
- National Institute for Health and Care Excellence. NICE technology appraisal and highly specialised technologies guidance: the manual (PMG36). Published 31 January 2022, last updated 13 October 2026. Sections 4.6.4, 4.12.4, 5.5.3, 5.5.11, 5.5.15 and 5.6.15. https://www.nice.org.uk/process/pmg36
- National Research Council. Independent verification and validation of critical software. In: An Assessment of Space Shuttle Flight Software Development Processes. Washington, DC: National Academies Press; 1993. https://doi.org/10.17226/2222
- Sargent RG. Verification and validation of simulation models. In: Proceedings of the 2011 Winter Simulation Conference. 2011:183-198. https://www.informs-sim.org/wsc11papers/016.pdf
- Vemer P, Corro Ramos I, van Voorn GAK, Al MJ, Feenstra TL. AdViSHE: a validation-assessment tool of health-economic models for decision makers and model users. PharmacoEconomics. 2016;34(4):349-361. https://doi.org/10.1007/s40273-015-0327-2
- Wright SJ, Gray E, Rogers G, Donten A, Payne K. A structured process for the validation of a decision-analytic model: application to a cost-effectiveness model for risk-stratified national breast screening. Applied Health Economics and Health Policy. 2024;22:527-542. https://doi.org/10.1007/s40258-024-00887-z
Related Concepts (8)
Frequently Asked Questions (6)
What is Independent Verification and Validation?
Independent verification and validation (IV&V) is verifying and validating a health economic model by a party independent of its developers and sponsor.
Source: Sargent 2011
Who carries out independent verification and validation of a health economic model?
Sargent describes four ways of deciding whether a simulation model is valid, and in this approach a third party makes the decision. That party is independent of both the team that developed the model and the model's sponsor or user, and it needs a thorough understanding of the purpose the model is meant to serve. Every one of Sargent's approaches assumes that the developers have already verified and validated the model while building it. In health economics the nearest form is review of a company model by an independent academic group that neither built the model nor paid for it.
Source: Sargent 2011
How does a NICE External Assessment Group compare with independent verification and validation?
After a company submission arrives, NICE sends it to the External Assessment Group (EAG), which critically evaluates the evidence and may amend the company's model in exploratory analyses. A company that submits a fully executable model must give NICE full access to the programming code. The EAG is independent of the company, but it reviews the submission for NICE, the body that uses the model, and NICE PMG36 refers to economic evaluations produced by EAGs on behalf of NICE. In Sargent's account of simulation model validation the third party is independent of the user as well, so the EAG fits that idea only in part.
Source: NICE PMG36 (2022, updated 2026)
Why does NICE have company models reviewed by an independent group, a partial form of independent verification and validation?
Ghabri and colleagues, one of them a NICE appraisal committee member and a director of an Evidence Review Group, give two reasons. Models submitted for reimbursement can be complex, so construction mistakes are unsurprising, and where two assumptions are equally plausible a company commonly picks the one more favourable to its product. In single technology appraisals the reviewers critique the company model and amend it where possible, though time limits often mean that structural problems are flagged but not corrected. The same authors suggest that scarce validation among 77 company submissions to the French Haute Autorité de Santé may reflect the time it takes and the difficulty of finding external experts without a conflict of interest.
Source: Ghabri et al. 2019
What should a report of independent verification and validation say about the reviewer?
The AdViSHE tool asks modellers whether the computerised model was examined by modelling experts and, if so, who those experts are and why they count as experts. It also asks whether they can be qualified as independent and where the results of the review are reported, including any unresolved issues. Independence is a matter of degree, since a reviewer can be technically independent of the modellers yet paid by the company whose product is modelled. A report that states which kinds of independence the reviewer meets lets a decision maker judge how much weight the checks deserve.
Source: Vemer et al. 2016
How does independent verification and validation differ from independent validation?
Eddy and colleagues call a validation independent when no information from the comparison source was used to build the model. That sense concerns the data, whereas independent verification and validation concerns the people doing the checking, since the checks on the model and the judgement of its fitness for purpose are made by a party that neither built nor paid for it. The same task force report suggests that data sources for external validation might be chosen by an independent panel, based on the intended use of the model and not on the chance of a successful result.
Source: Eddy et al. 2012
Trust Record
Verified by Dr Darrin Baines
British health economist
Professional identity: darrinbaines.org
Verification date: 12 Nov 2026
Content version: 1.0.0
Canonical Identity
- Term code
- HE-EM-MV-102
Stable URI · Machine-readable · Resolvable · CC BY 4.0