Concept Architecture
Independent Validation of Health Economic Models
Independent validation tests a health economic model against outcomes it had no chance to learn. The analyst simulates a study or registry that supplied nothing to the model's parameters or calibration, and compares the modelled and observed results. A good match on the data a model was built from says little, because the model was fitted to reproduce them, so agreement with a source it never saw is the more searching test of whether the model can predict. Independent validation is one kind of external validation and so belongs to model validation, which asks whether the model is the right one for the decision, as distinct from verification, which asks whether the model was built as specified. Sargent's historical data validation, a split-sample check in simulation science, is a close relative that AdViSHE files under a separate item.
What makes a validation source independent
The ISPOR-SMDM task force report by Eddy and colleagues grades every validation source by how far it was used in building the model. A validation is dependent when the same source was used both to estimate parameters and to validate, partially dependent when the source built or calibrated a part of the model that does not by itself wholly determine the outcome being checked, and independent when no information from the source was used to build the model. A source can be dependent for one part of a model and partially dependent for another, so the grading belongs to each pairing of source and outcome.
AdViSHE item D4 separates comparison against the data sources the model is based on (dependent validation) from comparison against a data source that was not used to build the model (independent validation). The PBAC guidelines, version 5.0, section 3A.7.1, ask Australian submissions to compare model traces with empirical data, considering sources used in the model and sources not used in it, and to explain any differences. Wright and colleagues call the second kind independent operational validation and judge it, intuitively, the stronger test, while noting that both kinds have key roles.
A source that has served as a calibration target has been used to build the model, so it can no longer give an independent validation of the outcomes it was used to fit. Eddy and colleagues describe dependent validations as closely related to calibration.
Two meanings of independent
Corro Ramos and colleagues point out that the word is used in two ways. In the first sense, independent validation compares model outcomes with empirical data that were not used to build the model. The term has also been used for validation carried out by a third party, known as independent verification and validation, which in Sargent's account uses a third party independent of both the development team and the model sponsor or user to decide whether the model is valid. The two senses can occur apart, since a company analyst can test a model against an unused registry and an outside reviewer can rerun only the developer's dependent checks.
Sargent's historical data validation uses part of a system's data to build the model and the remaining data to test it. Statistical cross-validation repeats such splits in rotation within one data set, guarding against overfitting, a model so closely tuned to its fitting data that it predicts new data poorly. AdViSHE files this split under item D3, Alternative Input Data Validation, which compares outcomes when the model runs on other literature sources or data sets, or on one part of a split data set validated against the other part.
Blinded validation and prediction
Eddy and colleagues call an independent validation blinded when those performing it had no information about the outcomes in the source, for example when articles on a trial's design and initial conditions are used to try to predict its results. Even with an unblinded source, information about the outcomes should not be allowed to influence the validation. The term is unrelated to blinding of patients or clinicians in a trial. They describe predictive validation as the most desirable type and say it ensures a completely independent validation, allowing no opportunities for altering the model to fit observed results.
Carrying out an independent validation of a decision model
The work starts with a log of every source that informed the parameters and calibration targets, because independence can only be shown against that list. Of Eddy and colleagues' general steps for external validation, three decide independence. Ideally the sources are fixed before results are known, chosen for the intended model use and not the likelihood of a successful validation. The set-up takes the source's population, treatment protocols and outcome definitions, never its health outcomes. Parameters are not refitted to the source, since a refit would make it dependent. AdViSHE item D4 also asks whether comparisons rest on summary statistics or patient-level data, whether differences could be explained and where the comparison is reported.
Worked example with three survival sources
All numbers in this example are illustrative. A partitioned survival model for a cancer drug predicts 3-year overall survival. Trial A supplied the fitted survival curves, so it is dependent. Trial C (300 patients) and Registry D (400 patients) reported after the model was finalised and supplied nothing, so both are independent. Assuming no censoring before 3 years, a simple check treats the modelled proportion as fixed and asks whether the observed proportion lies within binomial sampling error of it.
where is the standardised difference, is the observed proportion alive at 3 years in the source, is the modelled proportion for the simulated source population and is the number of patients in the source. Values of beyond plus or minus 1.96 suggest a difference larger than sampling error at the 5% level.
| Source | Status | Observed (%) | Modelled (%) | Absolute gap (points) |
|---|---|---|---|---|
| Trial A | Dependent | 42.0 | 41.5 | 0.5 |
| Trial C | Independent | 39.0 | 41.0 | 2.0 |
| Registry D | Independent | 36.0 | 41.0 | 5.0 |
1. Dependent check. Trial A is reproduced within 0.5 points, which confirms the curve fit and nothing more.
2. Trial C. The variance term is 0.41 × 0.59 = 0.2419, divided by 300 gives 0.000806, whose square root is 0.0284. The difference of 0.02 below the model gives = -0.02 / 0.0284 = -0.70, well inside sampling error. With 300 patients the test could still miss a gap of several points, so Sargent recommends judging gaps against an acceptable range of accuracy set early for the model's purpose.
3. Registry D. The variance term 0.2419 divided by 400 gives 0.000605, with square root 0.0246. The difference of 0.05 below the model gives = -0.05 / 0.0246 = -2.03, beyond sampling error.
4. Check the set-up instead of refitting. The registry reported age and performance status only in broad bands, and the first run took values near the trial's. Rerun with the band midpoints, a justifiable assumption for the registry's older and frailer patients, the model gives 38.5%. The variance term is 0.385 × 0.615 = 0.236775, divided by 400 gives 0.000592, square root 0.0243, and the difference of 0.025 gives = -0.025 / 0.0243 = -1.03. Eddy and colleagues say that when justifiable assumptions bring results together, the model can be called consistent with the actual results, and both runs are reported, the first as the baseline analysis because the rerun was prompted by the observed gap.
5. Interpret. The mean absolute gap is 0.5 points on the dependent source and (2.0 + 5.0) / 2 = 3.5 points on the independent sources, or (2.0 + 2.5) / 2 = 2.25 points after the set-up rerun. The dependent fit overstates predictive accuracy, and survival in routine care turns on a case mix the trial did not cover. With censored data the source's Kaplan-Meier standard error replaces the binomial one, and uncertainty in the model's own prediction widens the band further.
What HTA reviewers look for
The NICE manual, PMG36 (2022, updated 2026), asks for the methods and results of model validation (section 4.6.4), and section 4.6.20 asks that the external validity of an extrapolation be judged partly on coherence with external data such as historical cohort data sets. A reviewer such as an External Assessment Group needs the list of sources used to fit or calibrate the model, because a comparison with one of them is dependent however it is labelled. In a health technology assessment pilot at the French HAS covering 77 company cost-effectiveness analyses received in 2013 to 2017, Ghabri and colleagues found that only 35% performed any external validation, noting that independent external data cannot be easily found, especially for new health technologies. Their pragmatic steps include seeking independent data to validate model outputs and documenting the searches and results.
Limits and common misreadings
Eddy and colleagues want the studies chosen for validation to be independent, while accepting that this may be infeasible when the data are needed to build the model, and they add that partially dependent and even dependent validations can still be useful. Accuracy against a dozen trials is no guarantee for the next, and costs are harder to validate than events because resource use and unit costs vary between settings.
- Hidden dependence. A registry can share patients with a source used for a risk equation, which makes it at best partially dependent in effect although it never entered the model directly.
- Absolute events versus increments. Lopes and colleagues ran independent validations of the Core Obesity Model against 14 studies and found cardiovascular and mortality outcomes slightly underestimated, with a regression slope of 0.811. They note that underprediction present in both arms may be mitigated in incremental outcomes, provided it is independent of the treatment effect.
- Re-tuning after the fact. Once a model is adjusted to fit a source meant to test it, that source becomes dependent and the claim of independence lapses.
Sources
- Corro Ramos I, Feenstra T, Ghabri S, Al M. Evaluating the validation process: embracing complexity and transparency in health economic modelling. PharmacoEconomics. 2024;42:715-719. https://doi.org/10.1007/s40273-024-01364-0
- Eddy DM, Hollingworth W, Caro JJ, Tsevat J, McDonald KM, Wong JB. Model transparency and validation: a report of the ISPOR-SMDM Modeling Good Research Practices Task Force-7. Value in Health. 2012;15(6):843-850. https://doi.org/10.1016/j.jval.2012.04.012
- Ghabri S, Stevenson M, Möller J, Caro JJ. Trusting the results of model-based economic analyses: is there a pragmatic validation solution? PharmacoEconomics. 2019;37:1-6. https://doi.org/10.1007/s40273-018-0711-9
- Lopes S, Johansen P, Lamotte M, McEwan P, Olivieri AV, Foos V. External validation of the Core Obesity Model to assess the cost-effectiveness of weight management interventions. PharmacoEconomics. 2020;38:1123-1133. https://doi.org/10.1007/s40273-020-00941-3
- National Institute for Health and Care Excellence. NICE technology appraisal and highly specialised technologies guidance: the manual (PMG36). Published 31 January 2022, last updated 13 October 2026. Sections 4.6.4 and 4.6.20. https://www.nice.org.uk/process/pmg36
- Pharmaceutical Benefits Advisory Committee. Guidelines for preparing a submission to the PBAC, version 5.0. Section 3A.7, Model validation. September 2016. https://pbac.pbs.gov.au/section-3a/3a-7-model-validation.html
- Sargent RG. Verification and validation of simulation models. In: Proceedings of the 2011 Winter Simulation Conference. 2011:183-198. https://www.informs-sim.org/wsc11papers/016.pdf
- Vemer P, Corro Ramos I, van Voorn GAK, Al MJ, Feenstra TL. AdViSHE: a validation-assessment tool of health-economic models for decision makers and model users. PharmacoEconomics. 2016;34:349-361. https://doi.org/10.1007/s40273-015-0327-2
- Wright SJ, Gray E, Rogers G, Donten A, Payne K. A structured process for the validation of a decision-analytic model: application to a cost-effectiveness model for risk-stratified national breast screening. Applied Health Economics and Health Policy. 2024;22:527-542. https://doi.org/10.1007/s40258-024-00887-z
Related Concepts (3)
Frequently Asked Questions (6)
What is Independent Validation?
Independent validation compares a health economic model's outputs with observed data from a source that played no part in building or calibrating it.
Source: Eddy et al. 2012
How does independent validation differ from dependent validation of a health economic model?
The ISPOR-SMDM task force report by Eddy and colleagues grades each validation source by how far it was used to build the model. A validation is dependent when the same source supplied parameters and is then used to check the outputs, partially dependent when the source built or calibrated a part of the model that does not by itself wholly determine the outcome being checked, and independent when no information from the source was used. A source that served as a calibration target cannot give an independent validation of the outcomes it was used to fit. The grading applies to each pairing of source and outcome, so one study can play different roles for different parts of a model.
Source: Eddy et al. 2012
How is an independent validation of a health economic model carried out?
The analyst first logs every source that informed the parameters and calibration targets, because independence can only be shown against that list. Eddy and colleagues ask for validation sources to be chosen on the basis of intended model use, not convenience or the likelihood of a successful validation. The simulation is set up to match the source's population, treatment protocols and outcome definitions, without using its health outcomes. Parameters are not refitted to each source to achieve a good match, and a need to refit could indicate that a different model structure is more appropriate. When justifiable assumptions bring the results together, the model can be called consistent with the observed results.
Source: Eddy et al. 2012
What should a reviewer such as a NICE External Assessment Group check when a company reports an independent validation of its model?
NICE PMG36 (2022, updated 2026) asks companies to provide the methods and results of model validation in section 4.6.4. Section 4.6.20 asks that the external validity of an extrapolation be judged partly on its coherence with external data such as historical cohort data sets. A reviewer such as an External Assessment Group needs the list of sources used to fit or calibrate the model, because a comparison with one of them is dependent however the submission labels it. A claim of independent validation is therefore only as strong as the documentation showing that the comparison source played no part in building the model.
Source: NICE PMG36 (2022, updated 2026)
How often do company models submitted for health technology assessment include an independent validation?
A pilot study at the French National Authority for Health (HAS) reviewed 77 company cost-effectiveness analyses received between 2013 and 2017. Ghabri and colleagues found that only 35% performed any external validation. They noted that independent external data cannot be easily found, especially for new health technologies, which limits how many model outcomes can be validated this way. Their pragmatic steps for models intended for HTA include seeking independent data against which to validate model outputs and documenting the searches and results, so that reviewers can see what was attempted.
Source: Ghabri et al. 2019
Does independent validation mean validation by an independent third party?
Corro Ramos and colleagues point out that the term is used in two ways. In the usual sense, independent validation compares model outcomes with empirical data that were not used to build the model, and it is a kind of external validation. The term has also been used for validation carried out by a third party, which is the subject of independent verification and validation. The two senses can occur apart, since a company analyst can test a model against an unused registry while an outside reviewer may rerun only the developer's dependent checks, so a report should say which sense it means.
Source: Corro Ramos et al. 2024
Trust Record
Verified by Dr Darrin Baines
British health economist
Professional identity: darrinbaines.org
Verification date: 12 Nov 2026
Content version: 1.0.0
Canonical Identity
- Term code
- HE-EM-MV-105
Stable URI · Machine-readable · Resolvable · CC BY 4.0