False Negative Rate in AI Screening and Diagnostic Evaluation

The false negative rate measures how often a classifier misses what it is meant to find, counted only among the items that truly belong to the positive class. For an AI tool screening abstracts for a systematic review those items are the relevant records, and for a diagnostic algorithm they are the patients who have the condition. It is the complement of sensitivity, so a tool that finds 95% of relevant studies has a false negative rate of 5%. NICE ECD20 (2026), the NICE AI methods for evidence framework, makes this rate or its complement the primary metric for AI title and abstract screening, because a missed study can change what a review concludes. In economic evaluation of tests the same rate sets how many patients enter the missed-diagnosis branch of a model.

Calculating the rate within the reference standard positives

Every item is classed twice, once by the model and once by the reference standard, which gives the four cells of a two-by-two table. The false negative rate uses only the column of items the reference standard calls positive.

FNR=FNTP+FN=1−TPR\text{FNR} = \frac{FN}{TP + FN} = 1 - \text{TPR}

where FNR is the false negative rate, FN is the number of positive items the model labels negative, TP is the number of positive items the model labels positive, TP + FN is the total number of positives according to the reference standard, and TPR is the true positive rate.

Fawcett (2006) defines the true positive rate as positives correctly classified over total positives, also called the hit rate and recall, which clinicians call sensitivity. The false negative rate is the rest of that column. It is a conditional probability, the chance of a negative label given a truly positive item, and it is the numerator of the negative likelihood ratio, which divides it by specificity.

The positive class has to be fixed before counting. In title and abstract screening NICE ECD20 (2026) treats a relevant record as positive, and in data extraction an available data item, so a false negative is a relevant record wrongly excluded or a data item missed or extracted wrongly. The Confusion Matrix page sets out all four cells, and the False Positive Rate page covers the matching error among negatives.

Why the rate holds steady when prevalence changes

Fawcett (2006) explains that the class distribution is the ratio of the positive column to the negative column. Measures that mix both columns, such as accuracy, precision and the F score, shift when that ratio shifts even if the classifier is unchanged, while a single-column ratio does not. The false negative rate is a single-column ratio, so in principle it does not move with prevalence.

The quantity that does move is the share of negative results that are in fact positive, which is one minus the negative predictive value. Trevethan (2017) warns against the confusion of the inverse, reading a property of people with the condition as if it described people with a given test result. A false negative rate of 5% says that 5% of relevant records were excluded. It does not say that 5% of excluded records are relevant, and when relevant records are rare the second figure is usually far smaller.

How NICE ECD20 uses the false negative rate

NICE ECD20 (2026) gives its reason for putting this rate first. Relevant records are usually a small share of a search yield, and missing them can change the evidence base and the findings of a review. Where AI does a first sift and humans screen everything it keeps, avoiding false negatives takes priority over avoiding false positives, and aggregate measures such as the F-score, accuracy and the Matthews correlation coefficient are no substitute for reporting the false negative rate and its complement.

The framework sets several expectations for automated exclusion.

  1. Comparison with human screening. The false negative rate should be shown to be no higher than that expected from standard human screening. Human reviewers are not treated as error-free or given a fixed target, and AI is expected only to match humans working to their usual protocols.
  2. Review of each miss. Every false negative is first reviewed manually to decide whether the disagreement was caused by the human screener, the AI or an unclear reference standard.
  3. Reporting. The false negative rate and true positive rate are reported with measures of uncertainty, alongside the number of records screened, the prevalence of included studies and the absolute number of false negatives.
  4. Ongoing sampling. Humans check a random sample of AI exclusions, with the proportion sampled reflecting the acceptable false negative rate, the expected share of misses among the exclusions and the desired confidence, often 95%.

NICE ECD20 (2026) also asks that a model or API failure default to keeping the record or passing it to a human reviewer, never to excluding it, and states that a missed record matters more in a review directly informing a guidance recommendation than in a surveillance review. For data extraction it notes that missed or wrongly extracted items may outnumber spurious ones.

Earlier screening research used fixed targets, and Cohen and colleagues (2006) assumed a recall of at least 0.95, a false negative rate of 0.05 or lower, where the NICE framework benchmarks AI against human screening.

Worked example with a validation set and a sample of exclusions

All numbers in this example are illustrative. A team validates a large language model screener on 3,000 records from a past review, where double screening with adjudication marked 120 records as relevant.

1. Count the misses. The model excludes 6 of the 120 relevant records, so FN = 6 and TP = 114.

2. Compute the rate. FNR = 6 / 120 = 0.05 and TPR = 114 / 120 = 0.95.

3. Compare with humans. A single human screener working to the usual protocol missed 9 of the same 120 records, a rate of 9 / 120 = 0.075. The model rate of 0.05 is lower.

4. Review the misses. Manual review finds that 2 of the 6 excluded records were wrongly marked relevant in the reference standard. Those 2 become true negatives, so the positives fall to 118, FN = 4 and FNR = 4 / 118 = 0.034. Errors in the benchmark had inflated the rate. Re-checking only the records the model missed tends to flatter the model, a bias Hadgu (1999) shows for discrepant analysis, so the human screener's 9 misses in step 3 need the same review against the corrected reference standard before the two rates are compared.

5. Sample the exclusions in a live review. In a new review the model excludes 6,400 of 8,000 records, and humans screening the 1,600 it keeps find 150 relevant. A random sample of 300 exclusions contains no relevant record. Eypasch and colleagues (1995) restate Hanley's simple rule for zero events, that the upper limit of the 95% confidence interval is about 3 / n when n is above 30.

pupper≈3np_{\text{upper}} \approx \frac{3}{n}

where pupperp_{\text{upper}} is the one-sided upper 95% confidence limit for the share of relevant records among the exclusions and n is the number of exclusions sampled. Here 3 / 300 = 0.01. Applied to 6,400 exclusions this allows up to 0.01 × 6,400 = 64 missed records, so the false negative rate could be as high as 64 / 214 = 0.299, where 214 is the 150 found plus the 64.

6. Size the sample. To support a false negative rate of 0.05 with 150 found, the misses must satisfy FN / (150 + FN) ≤ 0.05, so FN ≤ 0.05 × 150 / 0.95 = 7.89. That is a share of 7.89 / 6,400 = 0.00123 of the exclusions, and the rule gives n ≈ 3 × 6,400 / 7.89 ≈ 2,430 sampled exclusions with no relevant record found, though an exact finite-population calculation needs about 2,000.

7. Interpret. The rate in step 4 rests on only 118 relevant records, and the clean sample of 300 in step 5 bounds the live rate only loosely, because certainty depends on the number of positives and not on the total screened.

Missed patients in decision models and what they cost

For a diagnostic or screening technology the false negative rate goes straight into the decision tree. Rautenberg and colleagues (2020) parameterise the disease-positive arm with sensitivity and its complement, one minus sensitivity, and treat the four results as intermediate outcomes, two favourable and two unfavourable, that lead on to final outcomes such as survival. They also report that models which include diagnostic accuracy have produced higher incremental cost-effectiveness ratios than models that leave it out. In a cost-effectiveness analysis each false negative carries the costs and QALY losses of delayed or missed treatment.

Fawcett (2006) shows that the best operating point depends on the class balance and on the relative cost of the two errors. A simple expected misclassification cost per person makes the trade visible.

E[C]=π×FNR×CFN+(1−π)×FPR×CFPE[C] = \pi \times \text{FNR} \times C_{FN} + (1 - \pi) \times \text{FPR} \times C_{FP}

where E[C]E[C] is the expected misclassification cost per person tested, π\pi is the prevalence, FNR is the false negative rate, CFNC_{FN} is the cost of one false negative, FPR is the false positive rate and CFPC_{FP} is the cost of one false positive.

Take illustrative values of π\pi = 0.02, CFNC_{FN} = GBP 8,000 and CFPC_{FP} = GBP 400. Test A has FNR 0.10 and FPR 0.15, so its two terms are 0.02 × 0.10 × 8,000 = 16.0 and 0.98 × 0.15 × 400 = 58.8, a total of GBP 74.80 per person. Test B has FNR 0.05 and FPR 0.25, so its terms are 0.02 × 0.05 × 8,000 = 8.0 and 0.98 × 0.25 × 400 = 98.0, a total of GBP 106.00. In a cohort of 10,000, test B misses 10 cases instead of 20 yet costs more in errors, because at 2% prevalence false positives far outnumber false negatives. A full analysis would add QALYs for each branch, as AI diagnostic value and screening economics describe.

Thresholds and the trade with false positives

A model that outputs a score yields a different false negative rate at each cut-off. Lowering the cut-off labels more items positive, so the false negative rate can only stay level or fall while the false positive rate can only stay level or rise. As Fawcett (2006) shows, plotting the true positive rate against the false positive rate across cut-offs gives the ROC curve, so each point has a false negative rate of one minus its height.

The cut-off is therefore a choice about which error to accept, and a test can report perfect specificity while missing many cases. For AI screening of evidence, NICE ECD20 (2026) states that where AI scores support human screeners, those scores should not set a predefined exclusion threshold.

Common misreadings of the false negative rate

The same few errors recur when the rate is reported for AI tools or diagnostic tests. Each can make a tool look safer than it is.

  1. Quoting a rate without counts. A rate of 5% may mean 1 missed record or 50, which is why NICE ECD20 (2026) asks for the absolute number and the sample size.
  2. Treating the reference standard as perfect. Errors in the human benchmark appear as false negatives that are not real, as step 4 shows.
  3. Treating it as a Type II error. A Type II error is failing to reject a false null hypothesis in a statistical test, while the false negative rate here is the share of truly positive items a classifier labels negative, estimated from a validation set.

Sources

Library

Publications

6
  • Report

    Development of an Evaluation Instrument on Artificial Intelligence Search Tools for Evidence Synthesis — Canada's Drug Agency (CDA-AMC), Vol. 4, No. 10 ed., 2024 (Canadian Journal of Health Technologies)

    How the Canadian HTA agency built an instrument to test AI search tools before trusting them in evidence synthesis.

  • Journal article

    SA18 Calibrating Large Language Model Probabilities to Achieve Target Recall in Systematic Review Screening — Abogunrin S, Sieiro RR, Lane M, Vol. 28, No. 12, p. S647 ed., 2025 (Value in Health)

    Poster abstract on calibrating LLM probabilities so screening reaches a set recall target.

  • Journal article

    MSR36 Artificial Intelligence in Systematic Reviews: An Investigation Into the Impact of Eligible Studies Being Excluded by Artificial Intelligence — Bishop E, Sanderson A, Reddish K, et al, Vol. 28, No. 12, p. S499 ed., 2025 (Value in Health)

    Conference poster abstract on what happens to review findings when AI wrongly excludes eligible studies.

  • Guidance

    Guidance for using artificial intelligence for title and abstract screening while conducting knowledge syntheses — Hamel C, Hersi M, Kelly SE, et al, Vol. 21, No. 1, Article 285 ed., 2021 (BMC Medical Research Methodology)

    Practical guidance on when and how machine learning screening can be used in a knowledge synthesis without losing relevant studies.

  • Journal article

    Machine learning reduced workload with minimal risk of missing studies: development and evaluation of a randomized controlled trial classifier for Cochrane Reviews — Thomas J, McDonald S, Noel-Storr A, et al, Vol. 133, pp. 140-151 ed., 2021 (Journal of Clinical Epidemiology)

    Shows a trained RCT classifier cut Cochrane screening workload while missing very few relevant studies.

  • Journal article

    Using text mining for study identification in systematic reviews: a systematic review of current approaches — O'Mara-Eves A, Thomas J, McNaught J, et al, Vol. 4, No. 1, Article 5 ed., 2015 (Systematic Reviews)

    Much-cited review of text mining to find studies for systematic reviews, on which later AI screening work builds. The publisher has issued an erratum to this article.

Frequently Asked Questions (6)

  • What is False Negative Rate?

    The false negative rate (FNR) is the share of truly positive cases, such as relevant studies or ill patients, that a test or AI model labels negative.

    Source: NICE ECD20 (2026)

  • How is the false negative rate calculated for an AI tool that screens abstracts for a systematic review?

    Each record is classed twice, once by the AI tool and once by a reference standard such as double human screening with adjudication. The false negative rate counts the relevant records the tool excluded and divides them by all records the reference standard marks as relevant, so it equals one minus the true positive rate. In an illustrative validation set of 3,000 records with 120 relevant, a tool that excluded 6 of them would have a rate of 6 divided by 120, or 0.05. NICE ECD20 asks for the rate to be reported with its uncertainty and the absolute number of misses.

    Source: NICE ECD20 (2026)

  • Why does NICE ECD20 treat the false negative rate as the primary metric for AI title and abstract screening?

    Relevant records usually make up a small share of what a literature search returns, and losing even a few can change the evidence base and the conclusions of a review. When AI does a first sift and humans screen every record it keeps, NICE ECD20 gives avoiding false negatives priority over avoiding false positives. Aggregate measures such as accuracy or the F-score may help model developers, but the framework says they are no substitute for reporting the false negative rate and its complement. It also expects the AI rate to be shown to be no higher than that of standard human screening.

    Source: NICE ECD20 (2026)

  • How does the false negative rate enter a decision tree model in a health economic evaluation of a diagnostic test?

    In a decision tree the arm for people who have the disease splits by test result, using sensitivity for true positives and its complement, one minus sensitivity, for false negatives. Rautenberg and colleagues treat the four test results as intermediate outcomes, with false negatives among the unfavourable ones, which then lead on to final outcomes such as survival. In a cost-effectiveness analysis each false negative carries the costs and QALY losses of delayed or missed treatment. Rautenberg and colleagues also report that models including test accuracy have produced higher incremental cost-effectiveness ratios than models that leave it out.

    Source: Rautenberg et al. 2020

  • Why does the false negative rate stay steady when prevalence changes, while the negative predictive value does not?

    The false negative rate is calculated within one column of the two-by-two table, the items the reference standard calls positive. Fawcett explains that ratios built from a single column do not depend on the class distribution, whereas measures that mix the positive and negative columns, such as accuracy and precision, shift when that balance shifts. The negative predictive value looks at everyone with a negative result and so draws on both columns. A screening tool with a false negative rate of 5% has excluded 5% of relevant records, yet when relevant records are rare far fewer than 5% of its exclusions are relevant.

    Source: Fawcett 2006

  • How can a review team bound the false negative rate of AI exclusions when a random sample of them contains no relevant record?

    The rule of three described by Eypasch and colleagues gives an approximate one-sided upper 95% confidence limit of 3 divided by the sample size when no events are seen, for samples above 30. In an illustrative review where the tool excludes 6,400 records and humans find 150 relevant among those it keeps, a clean sample of 300 exclusions caps the share of relevant exclusions at about 0.01. That still allows up to 64 missed records, which is a false negative rate as high as 64 divided by 214, or 0.299. A much larger sample is needed before the bound becomes tight.

    Source: Eypasch et al. 1995

Trust Record

Verified by Dr Darrin Baines

British health economist

Professional identity: darrinbaines.org

Verification date: 10 Nov 2026

Content version: 1.0.0

Canonical Identity

Term code
HS-HP-DH-079

Stable URI · Machine-readable · Resolvable · CC BY 4.0

This article is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/concept/false-negative-rate