Author-reviewedEvidence: highv1.0.3

Comparator Selection

Comparator selection is the HTA step that decides which existing treatments a new technology is compared with, usually current care or what it replaces.

Status
Published, version 1.0.3
Last reviewed
20 Oct 2026, by Dr Darrin Baines
Report a problem
Tell us if something is wrong or out of date

Concept Architecture

Comparator Selection and How HTA Bodies Decide What a New Technology Is Compared With

In a health technology assessment, the comparators for a new medicine, device or programme are chosen at the scoping stage, before any model is built. Most agencies start from current practice, meaning what patients would receive, or what the new technology would replace, if it were not adopted. The choice fixes the reference point for every incremental cost, incremental QALY and ICER that follows, so a well-built model with the wrong comparator set still answers the wrong question.

Selection is a process distinct from the comparator it produces. The choice is made in the NICE scope or the PICO of an EU joint clinical assessment, guided by the criteria of NICE, the Australian PBAC, the German G-BA and IQWiG, and CADTH, and by evidence of what current practice is. An illustrative example shows how adding one established but cheap option to the candidate list reverses an adoption decision. Comparator types, treatment-mix comparators and the mechanics of fully incremental analysis are covered on the comparator page.

Where the choice is made in scoping and the PICO

Comparator selection follows from the decision problem, so it happens before evidence is assembled. The EUnetHTA guideline on choosing comparators recommends that the most appropriate comparators be identified before an assessment begins or in its early phase. The formal vehicle is the scope, usually written as a PICO, which sets out population, intervention, comparators and outcomes.

In England the NICE manual (PMG36) describes scoping as the stage that defines what question the evaluation will answer, including the population, comparators, care pathway and outcome measures. The scope identifies all potentially relevant comparators that are established practice in the NHS, and at this stage identifying comparators should be inclusive (section 2.2.12). Stakeholders comment on a draft scope over 28 days, or 14 days when uncertainty is small, and NICE may hold a scoping workshop. The final call is made later by the appraisal committee, which must decide on the appropriateness and relevance of comparator technologies (section 6.2.1).

Under the EU HTA Regulation (Regulation (EU) 2021/2282, Article 8(6)), the scope of a joint clinical assessment must be inclusive, reflect Member States' needs and cover the patient population, the interventions, the comparators and the health outcomes. The HTA Coordination Group's scoping guidance collects each Member State's needs through a PICO survey and then consolidates them into the lowest possible number of PICOs, each with one comparator that can include more than one treatment. Recital 28 of the Regulation accepts that a joint report may contain several comparators of which only a selection is relevant to a given Member State, so national bodies still draw their own conclusions on clinical added value from the comparisons relevant to them.

Selection criteria used by HTA bodies

The broad rule is similar everywhere. The EUnetHTA guideline found broad agreement across European countries that a comparator is commonly defined as current routine care, the most used option, or what the new technology would replace. The table summarises how four systems apply it.

Body and documentStarting ruleFurther criteria
NICE, PMG36Established NHS practiceCommittee also weighs natural history without suitable treatment, existing NICE guidance, the comparator's cost effectiveness and its licensing status (6.2.2); unlicensed options allowed if established practice (6.2.4); technologies recommended with managed access are not suitable comparators (2.2.15)
PBAC, Guidelines version 5.0The therapy prescribers would most replaceJudged on what would be likely to happen rather than what should happen; usually the listed analogue used by the largest number of patients; a near-market medicine may be added as a contingency comparator (1.1.3)
G-BA and IQWiG, AMNOGAn appropriate comparator therapy specified by the G-BAAppropriate by the generally accepted state of medical knowledge, preferably established in practice and not excluded by the efficiency principle; judged against the actual care situation without the new medicine; may be best supportive care or watchful waiting
CADTH, 2017 guidelinesCurrent careAll interventions currently used and potentially displaced, plus those likely to be available soon; best supportive care considered where current technologies may be of poor or uncertain value

Germany shows how a legal framework shapes the choice. The benefit assessment ordinance (AM-NutzenV, section 6) requires the comparator therapy to be determined, as a rule, by criteria drawn from international standards of evidence-based medicine, and requires the same comparator therapy for medicines of one active-substance class so that assessments stay consistent. IQWiG's General Methods (version 8.0) state that when several alternatives are equally suitable, showing added benefit over one is sufficient, although the dossier must still include the costs of every option the G-BA specified.

Evidence that an option is current practice

Selection needs evidence on what patients receive now. The EUnetHTA guideline lists, in order of preference, national reimbursement lists, prescription statistics, market surveys, discussion with clinical specialists and patient organisations, registries and validated clinical protocols. It also asks for published evidence on the comparator's efficacy and safety, and for a pharmaceutical comparator to be dosed in line with its marketing authorisation or high-quality guidelines.

Assumptions and judgements that shape the comparator set

Every selection rule rests on a view of what would happen without the new technology. These judgements are rarely neutral, because each one can add or remove a candidate.

  • Likely practice or ideal practice. The PBAC asks what would be likely to happen, not what should happen. NICE is normally guided by established practice, but when an established option may not be a good use of NHS resources, the committee decides whether to keep it as a comparator after reviewing an incremental analysis, guided by whether it is recommended in other NICE guidance, or whether its use is so embedded that it will continue unless a new technology replaces it (section 6.2.3).
  • Concept before data. The CADTH guidelines state that selection should be conceptually driven and not determined by the availability of data. A trial control that happens to exist does not become the comparator by default.
  • Timing. Practice changes, so the comparator set is fixed at a date. The EU scoping guidance generates PICOs from the situation prevailing at the time of the survey, and both PBAC and CADTH expect options about to reach the market to be considered.
  • Subgroups. Where severity, line of therapy or biomarkers alter what patients would otherwise receive, different subgroups can have different comparators. The PBAC allows this when the main comparator cannot be used in a subpopulation, and EUnetHTA recommends identifying the extra comparators clearly.

Worked example in which one extra candidate reverses the decision

All figures, including the threshold of GBP 30,000 per QALY, are illustrative and invented for teaching. A new medicine N is assessed in a population where most patients receive a branded medicine A, a pharmacological analogue of N, and a minority receive C, an inexpensive generic used off-label but established in practice. Expected lifetime costs and QALYs per patient are GBP 4,000 and 4.60 QALYs for C, GBP 12,000 and 4.80 for A, and GBP 17,000 and 5.00 for N.

1. Selection by displacement alone. If the analysis compares N only with A, the therapy prescribers would most replace, the ICER is

ICERN,A=CN−CAEN−EA=17000−120005.00−4.80=50000.20=25000\text{ICER}_{N,A} = \frac{C_N - C_A}{E_N - E_A} = \frac{17000 - 12000}{5.00 - 4.80} = \frac{5000}{0.20} = 25000

where CC is the expected cost per patient in GBP and EE the expected QALYs per patient for each option. At GBP 25,000 per QALY, N looks cost-effective at the illustrative threshold.

2. Selection of every established option. If C enters the candidate list as established practice, as an inclusive scope requires, the three options are ranked by QALYs. Moving from C to A costs GBP 8,000 for 0.20 QALYs, an ICER of GBP 40,000 per QALY, and moving from A to N costs GBP 25,000 per QALY. Because the ICER falls along the sequence, A is extendedly dominated, so it is removed and N is compared with C as follows.

ICERN,C=CN−CCEN−EC=17000−40005.00−4.60=130000.40=32500\text{ICER}_{N,C} = \frac{C_N - C_C}{E_N - E_C} = \frac{17000 - 4000}{5.00 - 4.60} = \frac{13000}{0.40} = 32500

where the symbols are as before, with subscript CC denoting the generic option. At GBP 32,500 per QALY, N is not cost-effective at the illustrative threshold.

3. The same answer in net benefit. Net monetary benefit at GBP 30,000 per QALY is 30,000 × 4.60 − 4,000 = GBP 134,000 for C, 30,000 × 4.80 − 12,000 = GBP 132,000 for A and 30,000 × 5.00 − 17,000 = GBP 133,000 for N. N beats A by GBP 1,000 per patient but falls GBP 1,000 short of C.

4. Interpretation. Nothing in the model changed between steps 1 and 2; only the candidate list did. The example is the case PMG36 section 6.2.3 anticipates, in which A is established practice but not a good use of resources relative to C. If the committee judges that A's use is so embedded that it will continue unless replaced, the comparison of N with A carries weight for patients who would otherwise stay on A; if C is a genuine alternative for them, the decision rests on N against C. CADTH's advice to consider best supportive care has the same aim, which is to show when a technology looks cost-effective only against a historically adopted option of poor value.

Using a contested comparator set in decisions

When the comparator set is disputed, the analysis can show each candidate set's result instead of hiding the choice. The CADTH guidelines ask for uncertainty about the choice and sequence of comparators to be explored through scenario analyses, and for the removal of any identified comparator to be justified. A scenario analysis of this kind does not measure parameter uncertainty; it tells the decision maker which judgement about practice the recommendation depends on.

In Germany the comparator also affects price. IQWiG's General Methods explain that when several alternatives form the appropriate comparator therapy, the one that is most efficient in annual treatment costs is used when the reimbursement amount is agreed, so IQWiG's health economic evaluations also analyse the cheapest and the most expensive of the equally appropriate options.

Related ideas that are easily confused with comparator selection

Several nearby terms describe different objects. Mixing them up lets the available evidence decide the comparator instead of the decision problem.

  • The comparator. The comparator is the alternative itself. Comparator selection is the process and the rules that pick it.
  • Main comparator. A PBAC term for the single therapy most likely to be replaced, which anchors an Australian submission.
  • Common comparator. An evidence-synthesis anchor, often placebo, that links trials in an indirect comparison or network meta-analysis. It is often not a decision comparator at all.
  • Trial control. The EUnetHTA guideline notes that, for marketing authorisation, the EMA and FDA specify a placebo or an active comparator, which answers the regulator's question, not necessarily the payer's.

Common errors in choosing comparators

Comparator rules leave room for judgement. Several errors recur in submissions and published evaluations.

  • Letting the trial choose. Using the control arm of the main trial because head-to-head data exist breaks the CADTH principle that selection is conceptually driven.
  • One comparator for every jurisdiction. EUnetHTA reports that in many circumstances European countries do not agree on what routine care is, and that in some countries the choice is governed by legislation and can also refer to cost, so a comparator valid in one country can be irrelevant in another.
  • Dropping the cheap option. Leaving out an inexpensive established treatment, as step 1 of the example shows, can make a new technology look cost-effective against an option that is itself poor value.
  • A stale candidate list. A comparator set fixed long before the decision can omit a near-market entrant or a newly generic medicine, which is why PMG36 allows the scope to be updated when there is a long gap before the evaluation.
  • Undefined standard care. The EU scoping guidance states that simply naming standard of care is not sufficient; its components must be specified for the health system concerned.

Sources

  • CADTH. Guidelines for the Economic Evaluation of Health Technologies: Canada. 4th ed. Ottawa: CADTH; March 2017. Sections 4.1 and 4.2 and the Decision Problem and Comparators chapters.
  • EUnetHTA. Comparators and comparisons: criteria for the choice of the most appropriate comparator(s). Summary of current policies and best practice recommendations. EUnetHTA Joint Action 2, Work Package 7 guideline, adapted version November 2015 (based on the February 2013 guideline).
  • HTA Coordination Group. Guidance on the scoping process, version 1.0, 13 November 2024 (adopted 28 November 2024 under Regulation (EU) 2021/2282). Published on the European Commission health website; 2024.
  • Institute for Quality and Efficiency in Health Care (IQWiG). General Methods, version 8.0 of 19 December 2025. Cologne: IQWiG; 2025. Sections 4.3.2 and 4.10.
  • National Institute for Health and Care Excellence. NICE technology appraisal and highly specialised technologies guidance: the manual (PMG36). London: NICE; published 31 January 2022, last updated 13 October 2026. Sections 2.1.1, 2.2.12 to 2.2.15, 2.5.3, 2.7.1, 2.9.3 and 6.2.1 to 6.2.4.
  • Pharmaceutical Benefits Advisory Committee. Guidelines for preparing submissions to the Pharmaceutical Benefits Advisory Committee, version 5.0. Canberra: Australian Government Department of Health; September 2016. Section 1.1.3.
  • Regulation (EU) 2021/2282 of the European Parliament and of the Council of 15 December 2021 on health technology assessment and amending Directive 2011/24/EU. Official Journal of the European Union. 2021;L 458:1. Recital 28 and Article 8(6).
  • Arzneimittel-Nutzenbewertungsverordnung (AM-NutzenV) of 28 December 2010, BGBl. I p. 2324, as last amended on 4 March 2025 (BGBl. 2025 I No. 75). Section 6.

Institutional Perspectives (1)

  • PBAC

    "Therapy Most Likely To Be Replaced in Practice"; PBAC Can Reject the Nominated Comparator

    The submission must nominate as its main comparator the therapy prescribers would most replace with the proposed medicine — judged on what would likely happen in practice, not what should happen. A defined hierarchy applies (usually the pharmacological analogue already listed for the largest number of PBS patients in the target population). The comparator is not merely current best practice, and the PBAC can reject a sponsor’s nominated comparator and substitute another, which resets the entire clinical and economic evaluation built on it.

    Pharmaceutical Benefits Advisory Committee, Guidelines for Preparing a Submission to the PBAC, Sections 1.1–2.8View source →

Library

Publications

3
  • Other

    Arzneimittel-Nutzenbewertungsverordnung (AM-NutzenV), BGBl. I p. 2324, as last amended on 4 March 2025, section 6 ed., 2010 (Bundesgesetzblatt)

    Source listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Comparator Selection, where it is cited as a reference for that concept.

  • Guidance

    Guidelines for the Economic Evaluation of Health Technologies: Canada — CADTH, 4th edition ed., 2017 (CADTH)

    Guidance document listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Comparator Selection, where it is cited as a reference for that concept.

  • GuidanceFeatured

    NICE Health Technology Evaluations: The Manual (PMG36) — National Institute for Health and Care Excellence, PMG36 ed., 2022 (NICE)

    NICE’s consolidated methods and processes manual for health technology evaluation, defining the reference case for economic evaluation (perspective, comparators, time horizon, discounting, EQ-5D, cost-effectiveness thresholds and the severity modifier) — the authoritative HTA methods reference for the English NHS.

Frequently Asked Questions (6)

  • What is comparator selection?

    Comparator selection is the HTA step that decides which existing treatments a new technology is compared with, usually current care or what it replaces.

    Source: EUnetHTA 2015

  • What existing treatment does comparator selection identify?

    Comparator selection is the process of identifying the existing treatment against which a new technology will be evaluated in an economic evaluation. It picks the alternative the new technology should be measured against, usually the care patients would otherwise receive. It matters because a technology's value is always relative: judged against a weak comparator it may look better than it is, and against a strong one, worse. An appropriate comparator is the treatment genuinely in current use for the same patients, and its choice draws on the clinical guideline's account of the standard of care. Choosing what a technology is compared with is what it does. NICE sets this out.

    Source: NICE

  • What does comparator selection identify?

    Comparator selection identifies the appropriate existing treatment against which a new technology will be evaluated, so it chooses the reference treatment for the comparison in the economic evaluation. So comparator selection identifies the reference treatment, which is why it matters, since the comparison depends on it, and comparator selection identifies the appropriate existing treatment against which a new technology is evaluated, shaping the results and the conclusions the economic evaluation supports.

    Source: NICE, Health Technology Evaluations: The Manual

  • Why does comparator selection matter?

    Comparator selection matters because the treatment chosen as the comparator determines what the new technology is compared against, so the choice shapes the results of the economic evaluation and the conclusions drawn. So comparator selection matters for the evaluation results, which is why the choice is important, since the comparator is the reference, and comparator selection matters because the existing treatment chosen as comparator determines the basis for evaluating the new technology.

    Source: NICE, Health Technology Evaluations: The Manual

  • What makes a comparator appropriate?

    A comparator is appropriate when it is the relevant existing treatment the new technology would be used instead of or alongside, so that the comparison reflects the real choice in practice. So an appropriate comparator reflects the real alternative, which is why it is chosen carefully, since it should match practice, and a comparator is appropriate when it is the existing treatment the new technology realistically competes with in practice.

    Source: NICE, Health Technology Evaluations: The Manual

  • How does comparator selection relate to a clinical guideline in HTA?

    Comparator selection relates to a clinical guideline in HTA in that the guideline informs it: a clinical guideline in HTA provides context on the standard of care and comparator selection, and comparator selection identifies the treatment to compare against, guided by that standard of care. So the guideline informs comparator selection, which is why they are connected, since it indicates the standard of care, and comparator selection draws on the clinical guideline's context on standard of care to identify the appropriate comparator.

    Source: NICE, Health Technology Evaluations: The Manual

Trust Record

Verified by Dr Darrin Baines

British health economist

Professional identity: darrinbaines.org

Verification date: 20 Oct 2026

Content version: 1.0.3

Canonical Identity

Term code
HS-HP-HTA-046

Stable URI · Machine-readable · Resolvable · CC BY 4.0

This article is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/concept/comparator-selection