Author-reviewedEvidence: highv1.0.2

Adverse Event Reporting

Adverse event reporting sends suspected drug reactions and safety incidents to regulators or national systems, giving safety signals but not event rates.

Status
Published, version 1.0.2
Last reviewed
10 Oct 2026, by Dr Darrin Baines
Report a problem
Tell us if something is wrong or out of date

Concept Architecture

Adverse Event Reporting in Trial, Regulatory and Patient-Safety Systems

Adverse event reporting covers three routes. Trial investigators report to sponsors, and sponsors to regulators; clinicians, patients and companies report suspected drug reactions to medicines regulators; and NHS staff record patient-safety incidents in a national system. All three exist to detect new hazards fast rather than to measure frequency, so in an economic model the reports help decide which events to include, while their probabilities must come from other evidence. The rules summarised below are those current in October 2026, and under-reporting limits what the data can contribute to an economic evaluation. The events themselves are covered on the adverse event, adverse drug reaction and adverse drug event pages, and turning trial counts into model probabilities on the adverse event rate page.

Three reporting routes and what each one captures

The routes differ in who reports, what triggers a report and who receives it. Each selects a different subset of harm, which limits what its data can show.

RouteReporter and recipientWhat triggers a reportUK and US systems
Clinical trial safety reportingInvestigator to sponsor, sponsor to regulatorSerious adverse events; suspected unexpected serious adverse reactions (SUSARs)MHRA ICSR Submissions; FDA IND safety reports
Post-authorisation reportingHealth professionals, patients and companies to regulatorSuspected adverse drug reactionsYellow Card; FDA AEMS, formerly FAERS
Patient-safety incident recordingStaff and organisations to a national systemAny patient safety event, with or without harmLFPSE (NHS England)

Reporting serious adverse events and SUSARs in clinical trials

Trial reporting runs in two steps. The investigator tells the sponsor about serious adverse events, and the sponsor sends regulators expedited reports of those that are also unexpected and suspected to be caused by the product.

The ICH E2A guideline sets the clock. A fatal or life-threatening unexpected adverse drug reaction in a clinical investigation goes to regulators no later than 7 calendar days after the sponsor first knows the case qualifies, with as complete a report as possible within 8 additional days; other serious unexpected reactions go within 15 calendar days. An initial report needs only four minimum criteria, namely an identifiable patient, a suspect medicinal product, an identifiable reporting source, and a serious unexpected event with a reasonable suspected causal relationship.

In the UK the amended Clinical Trials Regulations took full effect on 28 April 2026. Current MHRA guidance keeps the 7-day and 15-day SUSAR timelines with the further 8 days for fatal or life-threatening cases, requires submission in the E2B(R3) format, and states that the investigator's immediate report of a serious adverse event to the sponsor should under no circumstances exceed 24 hours, although lower-risk trials may adapt this in the protocol under a risk-proportionate approach. In the United States, 21 CFR 312.32 requires IND safety reports within 15 calendar days, and within 7 days for an unexpected fatal or life-threatening suspected adverse reaction.

Reporting after licensing through individual case safety reports, Yellow Card and FDA AEMS

After a medicine is licensed, reports arrive as individual case safety reports (ICSRs). The ICH E2D(R1) guideline, adopted on 15 September 2025, defines an ICSR as a description of an adverse event or reaction in an individual patient at a specific point in time, and requires at least one event, one suspect or interacting product, an identifiable patient and an identifiable reporter.

E2D(R1) sets a general expedited timeline of no later than 15 calendar days after day zero, the date the marketing authorisation holder has enough information to meet the minimum criteria; non-serious reports follow regional timelines. ICH E2A notes that, for reporting purposes, spontaneous reports usually imply causality, which is a reporting convention and not a finding. In the United States, 21 CFR 314.80 requires 15-day Alert reports for each serious and unexpected adverse drug experience.

The UK's spontaneous scheme is the MHRA Yellow Card scheme, open to health professionals, patients and the public. For established medicines and vaccines the MHRA asks for all serious suspected reactions, even well-recognised ones, and for black triangle products under additional monitoring it asks for all suspected reactions; a reporter needs only a suspicion, not proof of causality. In the United States, MedWatch is the reporting programme for health professionals, patients and consumers, and the database that holds the reports, the FDA Adverse Event Reporting System (FAERS), has been renamed the FDA Adverse Event Monitoring System (AEMS), which the agency is implementing to consolidate reporting systems across product categories.

Patient-safety incident reporting in the NHS through LFPSE

Patient-safety reporting covers safety events from any part of care, medicines included, whether or not harm resulted. In England this is now done through the Learn from Patient Safety Events (LFPSE) service, a national system for recording and analysing patient safety events.

NHS England reports that more than 2.5 million patient safety events are recorded each year. Organisations have switched to LFPSE from the National Reporting and Learning System (NRLS), which was decommissioned on 30 June 2024, while the Strategic Executive Information System (StEIS) remains in use until the next version of LFPSE replaces it. Around three quarters of recording to the NRLS and StEIS came from hospitals. Official statistics were paused during the transition and resumed in April 2025 from LFPSE data, as official statistics in development, and NHS England publishes the NRLS and LFPSE series separately, with a transition report covering both.

How much harm goes unreported

Every reporting system sees a fraction of the harm that occurs. The gap has been measured by comparing reports with intensive surveillance or case note review.

Hazell and Shakir reviewed 37 studies from 12 countries that compared spontaneous reports with harm found by intensive data collection. The median under-reporting rate was 94% (interquartile range 82% to 98%), and 85% even in studies of specific serious or severe reaction and drug combinations. Incident reporting shows a similar gap. In a large NHS hospital, Sari and colleagues reviewed 1,006 admissions and found 324 patient safety incidents in 230 admissions; 83% were found only by case note review, 7% only by the reporting system and 10% by both, and of the 110 admissions with an incident causing harm the reporting system detected 6 (5%). Across three leading hospitals, Classen and colleagues found that voluntary reporting and the AHRQ Patient Safety Indicators missed 90% of adverse events, while the Global Trigger Tool found at least ten times more confirmed serious events.

What reporting data can and cannot tell an economic evaluation

A report count is a numerator without a denominator. The reporting system holds no exposure data; prescribing or sales figures give only an approximate denominator, the share of events reported is unknown and variable, and reports can be duplicated or incomplete. The FDA states on its AEMS dashboard page that the information in reports cannot be used to estimate the incidence of the events reported, and that a report does not establish causation.

Reporting data still have roles in health technology assessment. A cluster of reports can flag a rare or delayed reaction that trials were too small or too short to see, which may justify adding the event to a model and sourcing its probability from real-world evidence. Case narratives show how an event was managed, which helps build its costing pathway. Regulators can screen databases for disproportionate reporting, for example with the proportional reporting ratio, defined as follows.

PRR=a/(a+b)c/(c+d)PRR = \frac{a / (a + b)}{c / (c + d)}

where aa is the number of reports of the event of interest for the drug, bb is all other reports for the drug, cc is reports of the event for all other drugs and dd is all other reports for all other drugs. Evans and colleagues, testing it on the UK Yellow Card database, used at least 3 cases, a PRR of at least 2 and a chi-squared value of at least 4 as minimum criteria; of 481 signals for 15 newly marketed drugs, 70% were known reactions, 13% were probably related to the underlying disease and 17% needed further evaluation. A PRR compares shares of reports, so it shows where to look, not a probability of harm. This screening is the first step of signal detection in pharmacovigilance.

Patient-safety data work the same way. Incident reports show where harm clusters and so where a safety intervention might be aimed, but the baseline harm rate and the effect of the intervention need case note review, trigger tools or a trial; the harm rate page covers the measure.

Worked example of why a report count is not a probability

The figures are illustrative. A regulator holds 60 reports of a reaction to a drug that 200,000 patients took in a year, and an analyst wants to cost the reaction in a model.

Step 1. The naive reporting rate.

r=nN=60200000=0.0003r = \frac{n}{N} = \frac{60}{200000} = 0.0003

where rr is reports per treated patient, nn is the number of reports and NN is the number of patients treated. The result is 30 per 100,000.

Step 2. Correcting with a reporting fraction. If 6% of reactions were reported, matching the median under-reporting rate of 94%, the implied incidence is as follows.

p=rf=0.00030.06=0.005p = \frac{r}{f} = \frac{0.0003}{0.06} = 0.005

where pp is the implied incidence per treated patient and ff is the reporting fraction, giving 500 per 100,000, or 1,000 reactions among 200,000 patients. Across the interquartile range of under-reporting, ff runs from 18% to 2% and pp from about 0.0017 to 0.015, a ninefold range.

Step 3. Cost per treated patient. At an assumed GBP 3,000 per reaction, the naive rate gives GBP 0.90 per treated patient, the median correction GBP 15 and the range GBP 5 to GBP 45.

Interpretation. The reporting fraction for this drug and event is unknown, and published fractions come from other drugs, settings and years, so no correction turns the count into a defensible model input. The reports justify including the event and testing it in scenario analysis; the probability should come from a cohort or registry study with a known denominator.

Common misreadings of adverse event reports

Most errors come from treating a surveillance system as a measurement system. Four recur.

  1. Report counts as incidence. Without exposure data and a known reporting fraction, counts give neither rates nor valid risk comparisons between drugs.
  2. Reports as proof of cause. The FDA notes that the event may have come from the underlying disease or another drug.
  3. Expedited reports as the full safety record. SUSARs are the serious, unexpected and suspected-related subset; model inputs come from the full trial safety tables on both arms.
  4. Trends in incident numbers as trends in safety. A rise can reflect more reporting, and the NRLS to LFPSE switch interrupted the official statistics.

Sources

Institutional Perspectives (3)

  • FDA

    Device Deaths and Serious Injuries Reported by Manufacturers Within 30 Days

    FDA's medical device reporting rule requires manufacturers to report within 30 calendar days of becoming aware of information that reasonably suggests a device they market may have caused or contributed to a death or serious injury, or has malfunctioned in a way likely to do so if the malfunction recurred. A 5-day report is due when an event needs remedial action to prevent an unreasonable risk of substantial harm to public health. Device user facilities report deaths to FDA and the manufacturer, and serious injuries to the manufacturer, within 10 work days.

    US Food and Drug Administration, 21 CFR Part 803 Medical device reporting (eCFR, up to date as of 1 October 2026), sections 803.30(a), 803.50(a) and 803.53View source →
  • MHRA

    Device Serious Incidents Reported to the MHRA Within 2, 10 or 15 Days

    For medical devices placed on the Great Britain market from 16 June 2025, the MHRA requires manufacturers to report a serious incident no later than 2 calendar days after becoming aware of a serious public health threat, 10 days for a death or unanticipated serious deterioration in health, and 15 days for all other serious incidents, down from 30. Reports go through the MORE portal and should not be delayed by incomplete information. Manufacturers must also submit trend reports when incidents rise significantly in number or severity.

    Medicines and Healthcare products Regulatory Agency, Medical devices: post-market surveillance requirements (published 15 January 2025, last updated 5 September 2025), 'Introduction and scope' and 'Vigilance reporting requirements', sections c), d) and h), under Part 4A of the UK Medical Devices Regulations 2002 as inserted by the Medical Devices (Post-market Surveillance Requirements) (Amendment) (Great Britain) Regulations 2024View source →
  • WHO

    Incident Reporting Systems Should Yield Learning, Not Just Record Failure

    WHO's technical report on patient safety incident reporting and learning systems states that reporting systems should yield learning to improve safety rather than simply communicate failure. Staff will report incidents if they are protected from blame and retribution and involved in follow-up. Under-reporting happens in health care as in other sectors, but this should not lead to incident reports being disregarded. A single report seldom gives a definitive view of causation, so further investigation and analysis are needed to establish why an incident happened.

    World Health Organization, Patient safety incident reporting and learning systems: technical report and guidance (16 September 2020, ISBN 9789240010338), 'Ten facts on reporting and learning systems', facts 1, 2, 3 and 6View source →

Functions & Formulae (3)

s(a, b, c, d) = (PRR, X2, X2_Y, S)

Maps the four report counts of a two-by-two table for one drug and one event to the proportional reporting ratio, a chi-squared statistic on the same table and a flag under the minimum criteria of Evans and colleagues. The ratio has the form of HE-FM-PR-001, whose counts are people in a cross-sectional sample, while these counts are reports with no count of the patients exposed, so the output shows where to look and gives no probability of harm. Event probabilities, costs and QALY losses for a model stay with HE-FN-AER-001 and need a source with a known denominator. The naive reporting rate in the article has the form P = n / N of HE-FM-AER-001, and its correction by a reporting fraction takes the form of HE-FM-CRV-001 with a equal to the rate, Sp equal to 1 and Se equal to the fraction (derived), so neither is restated. Notation follows the Adverse Event Reporting article.

  • Proportional reporting ratio from the four report counts of one drug and event pair

    P_d = a / (a + b); P_o = c / (c + d); PRR = P_d / P_o

    Divides the share of the drug's reports that name the event of interest by the same share among the reports for all other drugs, using a two-by-two table of report counts with drugs in rows and events in columns. A value of 1 means the event takes the same share of reports for the drug as for the other drugs, and a value above 1 means a larger share. The arithmetic has the form of HE-FM-PR-001, but every cell here counts reports, so b is the other reports for the drug and not people free of the event, and no cell counts the patients exposed. Because P_d cannot exceed 1, the ratio cannot exceed 1 / P_o (derived). The ratio compares shares of reports, so it shows where to look and does not measure risk.

  • Chi-squared statistic of a two-by-two report table with expected counts from its margins

    N = a + b + c + d; E_a = (a + b) * (a + c) / N; E_b = (a + b) * (b + d) / N; E_c = (c + d) * (a + c) / N; E_d = (c + d) * (b + d) / N; X2 = (a - E_a)^2 / E_a + (b - E_b)^2 / E_b + (c - E_c)^2 / E_c + (d - E_d)^2 / E_d; Y = max(0, abs(a - E_a) - 0.5); X2_Y = Y^2 / E_a + Y^2 / E_b + Y^2 / E_c + Y^2 / E_d

    Compares each observed report count with the count expected if drug and event were independent, taken from the table as row total times column total over the grand total, and adds the squared gaps scaled by the expected counts. The summation has the form of HE-FM-CHISQ-007, whose E_j are model predictions for calibration targets (HE-VR-CHISQ-022), while E here comes from the margins of the table. The table has one degree of freedom (derived), which links the statistic to HE-FM-CHISQ-005. X2_Y is the Yates-corrected form, which takes 0.5 off the absolute gap in each cell, floored at zero; the absolute gap is the same in all four cells, so one Y serves them all. Both forms appear in published accounts of the signal criteria, so a reported value names the form used.

  • Flag under the Evans minimum criteria for a signal from report counts

    S = (a >= 3) and (PRR >= 2) and (X2 >= 4)

    Returns 1 when a drug and event pair has at least 3 reports of the event, a proportional reporting ratio of at least 2 from HE-FM-AER2-001 and a chi-squared value of at least 4 from HE-FM-AER2-002, the minimum criteria that Evans and colleagues used on the UK Yellow Card database, and returns 0 otherwise. All three parts must hold. The count guards against ratios built on one or two reports, the ratio sets a size for the gap in shares, and the statistic takes account of the number of reports behind it. A flag marks a pair for medical assessment and establishes neither a reaction nor a rate. The form of the statistic used is reported with the flag, since HE-FM-AER2-002 gives two.

View all formulae

Library

Publications

11
  • Other

    Patient safety data — NHS England, Statistics page, read as the Internet Archive capture of 9 September 2026 ed., 2026 (NHS England)

    NHS England statistics page on patient safety data, cited for the pause in official statistics during the transition from the National Reporting and Learning System to the Learn from Patient Safety Events service, their resumption in April 2025 using LFPSE data, and their quarterly publication as official statistics in development.

  • Other

    21 CFR 312.32 and 314.80: IND safety reporting and postmarketing reporting of adverse drug experiences — Code of Federal Regulations, eCFR text as of 1 October 2026 ed., 2026 (Electronic Code of Federal Regulations)

    US federal regulations on safety reporting for investigational new drugs and on postmarketing reporting of adverse drug experiences, cited for IND safety reports within 15 calendar days, notification of unexpected fatal or life-threatening suspected adverse reactions within 7 days, and 15-day Alert reports for serious and unexpected adverse drug experiences.

  • Guidance

    E2D(R1): Post-approval safety data: definitions and standards for management and reporting of individual case safety reports — International Council for Harmonisation, Step 4 final version, adopted 15 September 2025 ed., 2025 (International Council for Harmonisation)

    ICH guideline on managing and reporting post-approval safety data, cited for its definition of an individual case safety report, the minimum criteria of an identifiable patient, an identifiable reporter, at least one adverse event and at least one suspect product, and expedited submission no later than 15 calendar days after day zero.

  • Other

    MedWatch: the FDA safety information and adverse event reporting program — US Food and Drug Administration, Content current as of 2 October 2026 ed., 2026 (US Food and Drug Administration)

    FDA web page for MedWatch, the agency's safety information and adverse event reporting programme, cited for describing MedWatch as the medical product safety reporting programme for health professionals, patients and consumers, in the article's account of spontaneous reporting routes after licensing in the United States.

  • Guidance

    Clinical trials for medicines: collection, verification and reporting of safety events — Medicines and Healthcare products Regulatory Agency, Updated 15 July 2026 ed., 2026 (GOV.UK)

    MHRA guidance on safety events in clinical trials of medicines under the amended UK regulations in full effect from 28 April 2026, cited for SUSAR reporting within 7 days for fatal or life-threatening cases and 15 days otherwise, E2B(R3) format, and investigator reporting of serious adverse events to the sponsor within 24 hours.

  • Guidance

    The Yellow Card scheme: guidance for healthcare professionals, patients and the public — Medicines and Healthcare products Regulatory Agency, Guidance web page, last updated 24 July 2025 ed., 2025 (Medicines and Healthcare products Regulatory Agency)

    MHRA guidance on the UK Yellow Card scheme for reporting suspected adverse drug reactions, cited for the scheme collecting suspected reactions reported by healthcare professionals and members of the public, and for stating that reporters do not have to prove causality, since only a suspicion is needed.

  • Journal article

    'Global trigger tool' shows that adverse events in hospitals may be ten times greater than previously measured — Classen DC, Resar R, Griffin F, et al., Vol. 30, No. 4, pp. 581-589 ed., 2011 (Health Affairs)

    Study comparing methods of detecting adverse events in the same patient sample from three leading hospitals, cited for finding that voluntary reporting and the AHRQ Patient Safety Indicators missed 90 percent of adverse events, while the Global Trigger Tool found at least ten times more confirmed serious events than these methods.

  • Journal article

    Under-reporting of adverse drug reactions: a systematic review — Hazell L, Shakir SAW, Vol. 29, No. 5, pp. 385-396 ed., 2006 (Drug Safety)

    Systematic review of 37 studies from 12 countries comparing adverse drug reactions found by intensive data collection with those reported to spontaneous reporting systems, cited for a median under-reporting rate of 94% (interquartile range 82% to 98%), and of 85% for specific serious or severe reaction and drug combinations.

  • Other

    Learn from patient safety events (LFPSE) service — NHS England, Web page, read as the Internet Archive capture of 30 July 2026 ed., 2026 (NHS England)

    NHS England page on the Learn from Patient Safety Events service, the national NHS system for recording and analysing patient safety events, cited for over 2.5 million events recorded each year, the decommissioning of the National Reporting and Learning System on 30 June 2024, and continued use of StEIS until the next LFPSE version.

  • Journal article

    Use of proportional reporting ratios (PRRs) for signal generation from spontaneous adverse drug reaction reports — Evans SJW, Waller PC, Davis S, Vol. 10, No. 6, pp. 483-486 ed., 2001 (Pharmacoepidemiology and Drug Safety)

    Paper introducing proportional reporting ratios for signal generation from spontaneous reports in the UK Yellow Card database, cited for its minimum criteria of 3 or more cases, a PRR of at least 2 and chi-squared of at least 4, and for its 481 signals across 15 newly marketed drugs, 70% of them known reactions.

  • Journal article

    Sensitivity of routine system for reporting patient safety incidents in an NHS hospital: retrospective patient case note review — Sari AB, Sheldon TA, Cracknell A, Turnbull A, Vol. 334, No. 7584, p. 79 ed., 2007 (BMJ)

    Retrospective case note review of 1,006 admissions to a large NHS hospital in England, cited for finding 324 patient safety incidents in 230 admissions, 83% of them detected by case note review alone, and for showing that the routine reporting system detected only 6 (5%) of the 110 admissions with an incident causing harm.

Tools & Resources

1
  • Other

    FDA Adverse Event Monitoring System (AEMS) Public Dashboard — US Food and Drug Administration, Content current as of 11 March 2026 ed., 2026 (US Food and Drug Administration)

    FDA public dashboard for the Adverse Event Monitoring System, formerly FAERS, cited for its caveats that reports cannot be used to estimate incidence and do not establish causation, that many reports are duplicated or incomplete, and that events may stem from the underlying disease or other drugs, and for FDA implementing AEMS to consolidate reporting systems.

Frequently Asked Questions (6)

  • What is adverse event reporting?

    Adverse event reporting sends suspected drug reactions and safety incidents to regulators or national systems, giving safety signals but not event rates.

    Source: ICH E2D(R1) 2025; NHS England 2026; FDA 2026

  • What harm from care does adverse event reporting document?

    Adverse event reporting is the systematic process of documenting and communicating instances of patient harm from medical care. It documents the harms that care causes and communicates them to those who can act, so incidents are recorded rather than lost. It is used to identify patterns and target improvement, turning individual reports into lessons for the system. It is a systematic process, following defined channels rather than relying on chance mention. It works best under blame-free reporting, which encourages open disclosure by focusing on causes rather than blame. Recording harm from care to learn from it is what it does. Brennan and colleagues (1991) set this out.

    Source: Brennan et al. 1991

  • What does adverse event reporting document and communicate?

    Adverse event reporting documents and communicates instances of patient harm from medical care, so it records these instances and shares them, used to identify patterns and target improvement. This documenting and communicating of harm defines it. So adverse event reporting is the systematic process of documenting and communicating instances of patient harm from medical care, used to identify patterns and target improvement This use to identify patterns and target improvement is what adverse event reporting serves by recording harm.

    Source: Brennan et al. 1991

  • What is adverse event reporting used for?

    Adverse event reporting is used to identify patterns and target improvement, so by documenting and communicating instances of patient harm it helps spot patterns and direct improvement effort. This use to identify patterns and target improvement defines its purpose. So adverse event reporting is the systematic process of documenting and communicating instances of patient harm from medical care, used to identify patterns and target improvement This systematic character is what makes adverse event reporting an organised process for recording and sharing harm.

    Source: Brennan et al. 1991

  • What kind of process is adverse event reporting?

    Adverse event reporting is a systematic process, so it is an organised process of documenting and communicating instances of patient harm from medical care, used to identify patterns and target improvement. This systematic character defines it. So adverse event reporting is the systematic process of documenting and communicating instances of patient harm from medical care, used to identify patterns and target improvement This relationship is what makes blame-free reporting an approach shaping how adverse event reporting is done.

    Source: Brennan et al. 1991

  • How does adverse event reporting relate to blame-free reporting?

    Adverse event reporting relates to blame-free reporting as a process and an approach to it: adverse event reporting is the systematic process of documenting and communicating instances of patient harm, and blame-free reporting is an approach emphasising systemic factors behind an error rather than assigning individual blame, encouraging more open reporting. So blame-free reporting shapes how adverse event reporting is done, connected as the process and an approach that encourages it.

    Source: Brennan et al. 1991

Trust Record

Verified by Dr Darrin Baines

British health economist

Professional identity: darrinbaines.org

Verification date: 10 Oct 2026

Content version: 1.0.2

Canonical Identity

Term code
HS-NHS-HQ-003

Stable URI · Machine-readable · Resolvable · CC BY 4.0

This article is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/concept/adverse-event-reporting