Builds the Cholesky factor of a three-outcome correlation matrix from three free angles, so that every choice of angles gives a valid matrix. TSD 20 Appendix C.1 sets L_11 to 1, the second row to cos phi_22 and sin phi_22, and the third row to cos phi_32, sin phi_32 cos phi_33 and sin phi_32 sin phi_33, the three-outcome case of its equations 26 to 30, with each angle above 0 and below pi. The calculator has no trigonometric functions, so it takes the cosines c_22, c_32 and c_33, and the sines follow as positive square roots because the sine is positive on that interval. The correlations r_21 and r_31 are c_22 and c_32 themselves, and r_32 is the inner product of the second and third rows. HE-FM-CHOD-002 returns valid = 1 for every such matrix, and r_32 stays strictly inside the r_L and r_U of that record as c_33 moves (derived, 0 mismatches against numerical Cholesky factors on a grid of 12,167 cosine triples).

Signature

s_22 = sqrt(1 - c_22^2); s_32 = sqrt(1 - c_32^2); s_33 = sqrt(1 - c_33^2); l_32 = s_32 * c_33; l_33 = s_32 * s_33; r_32 = c_32 * c_22 + l_32 * s_22; u_3 = c_32^2 + l_32^2 + l_33^2
Inputs
InputsDefinitionUnit
c_22Cosine of phi_22, equal to the correlation of the second outcome with the first, above minus 1 and below 1dimensionless
c_32Cosine of phi_32, equal to the correlation of the third outcome with the first, above minus 1 and below 1dimensionless
c_33Cosine of phi_33, above minus 1 and below 1dimensionless
Output
s_22Sine of phi_22, the second diagonal entry of the factordimensionless
s_32Sine of phi_32dimensionless
s_33Sine of phi_33dimensionless
l_32Row 3, column 2 entry of the factordimensionless
l_33Row 3, column 3 entry of the factordimensionless
r_32Correlation of the third outcome with the seconddimensionless
u_3Sum of squares of the third row, which equals 1 and so gives the matrix its unit diagonaldimensionless

Function

Cholesky factorisation of a covariance or correlation matrix into its lower triangular factor

Maps a symmetric positive definite n by n matrix A, usually the covariance matrix of parameters estimated together, to the lower triangular matrix L with positive diagonal entries for which A equals L times L transposed, or stops at the first zero or negative pivot when no such factor exists. The two-parameter factor and draw x = mu + L z are live as HE-FM-PSA-001 and a whole PSA run on them is HE-CF-PSA-001, so neither is restated here. The upper triangular orientation error is HE-ER-PSA-001 and the cost of drawing jointly estimated parameters as if independent is HE-ER-PSA-002. The logit link that turns a sampled linear predictor into a probability takes the form of HE-FM-BINOM-007, and approximate limits on that predictor take the form of HE-FM-AN-001. This package adds what first appears at three parameters, namely the column algorithm with its cross-product term and the pivot test with a valid range for a correlation matrix assembled pair by pair. It also adds the spherical form that keeps a sampled correlation matrix valid in evidence synthesis, and the transform Neine and Curran use to carry correlated normal draws into beta and gamma inputs. Notation follows the Cholesky Decomposition article.

Try this function

Implementations

  • Excel

    Spherical factor and third correlation from named cosine cells

    With the cosines in CosPhiSecond, CosPhiThird and CosPhiLast, each entered directly or as =COS of an angle in radians, the formulas in order return the cells named SinPhiSecond, SinPhiThird, SinPhiLast, SphCholThirdSecond, SphCholThirdThird, SphCorrThirdSecond and SphRowLength.

    =SQRT(1-CosPhiSecond^2); =SQRT(1-CosPhiThird^2); =SQRT(1-CosPhiLast^2); =SinPhiThird*CosPhiLast; =SinPhiThird*SinPhiLast; =CosPhiThird*CosPhiSecond+SphCholThirdSecond*SinPhiSecond; =CosPhiThird^2+SphCholThirdSecond^2+SphCholThirdThird^2

Assumptions

  • Spherical angles restricted above 0 and below pi

    TSD 20 restricts each angle above 0 and below pi to make the parameterisation unique, so each cosine is above minus 1 and below 1 and each sine is above zero. In that range the third diagonal entry and the second diagonal entry are both above zero.

  • Separation of standard deviations from the spherical correlation matrix

    TSD 20 writes the between-studies covariance matrix as the diagonal matrix of standard deviations times R times the same diagonal matrix, so that separate priors can be placed on the standard deviations and on R. Each covariance is then s_i times s_j times the correlation, the form checked in HE-VT-PSA-001.

  • Outcome order affects priors placed through a Cholesky factor

    TSD 20 states that with the Cholesky form the resulting prior distributions for the between-studies correlations depend on the ordering of the outcomes and recommends a sensitivity analysis of that ordering. The check of a single matrix here does not depend on order, as the grid for HE-FM-CHOD-002 shows.

Worked examples

  • Neine and Curran's correlation matrix recovered from spherical cosines

    With c_22 and c_32 of 0.5 and c_33 of one third, the factor entries are about 0.2887 and 0.8165 and the third correlation is 0.5, the matrix and entries Neine and Curran print. Here c_33 is typed to seven decimals, as 0.3333333.

    c_22 = 0.5; c_32 = 0.5; c_33 = 0.3333333; s_22 = 0.8660254; s_32 = 0.8660254; s_33 = 0.9428091; l_32 = 0.2886751; l_33 = 0.8164966; r_32 = 0.5; u_3 = 1
  • Article's two correlations of 0.9 with an illustrative third cosine

    All numbers are illustrative. With c_22 and c_32 of 0.9, a third cosine of minus 0.9 gives a third correlation of 0.639, just above the lower limit of 0.62 in HE-EX-CHOD-004, so the article's failing value of 0 cannot be reached by any choice of c_33 (derived).

    c_22 = 0.9; c_32 = 0.9; c_33 = -0.9; s_22 = 0.4358899; s_32 = 0.4358899; s_33 = 0.4358899; l_32 = -0.3923009; l_33 = 0.19; r_32 = 0.639; u_3 = 1

Common errors

  • Independent priors placed directly on the elements of a correlation matrix

    TSD 20 warns that independent priors on the elements may give a sampled matrix that is not positive semi-definite. With three correlations drawn independently and uniformly over minus 1 and 1, about 38.3% of the triples are not positive definite (derived, one minus pi squared over 16, and 0.3830 on a midpoint grid of 8 million triples). The angles avoid this because each draw gives a valid matrix.

  • Angle in degrees passed to the Excel cosine

    Excel COS takes radians. An angle of 60 degrees entered as =COS(60) returns about minus 0.9524 instead of 0.5, which is still a legal cosine, so the matrix stays valid and the wrong correlation goes unnoticed. =COS(RADIANS(60)) returns 0.5.

Sources

  • TSD 20 on the spherical and Cholesky separation of a correlation matrix

    Bujkiewicz S, Achana F, Papanikos T, Riley RD, Abrams KR. NICE DSU Technical Support Document 20: Multivariate meta-analysis of summary data for combining treatment effects on correlated outcomes and evaluating surrogate endpoints. Report by the Decision Support Unit, 22 October 2019 (the text read; the DSU page lists an update of December 2022). Appendix C.1, Constructing prior distribution for the between-studies covariance matrix, section Separation by spherical decomposition, gives L_11 = 1 and equations 26 to 30 for the entries of row l as products of sines and cosines, restricts each angle above 0 and below pi for uniqueness, and writes each correlation as an inner product. Section Separation by Cholesky decomposition states that the resulting priors on correlations depend on the ordering of outcomes and recommends a sensitivity analysis. The text calls L upper triangular with R = L transposed L but indexes these equations by row l, and the records read them as rows of a lower triangular factor, which returns the same matrix.

    View source →

Canonical Identity

This formula is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/formula/spherical-cholesky-factor-giving-a-valid-three-outcome-correlation-matrix-from-free-angles

Spherical Cholesky factor giving a valid three-outcome correlation matrix from free angles | HealthEconomics.wiki