FDA interval for the ratio of within-subject standard deviations

For narrow therapeutic index drugs the FDA also compares the within-subject standard deviations of test and reference. The 90% interval for their ratio divides the estimated ratio by the square root of two F quantiles, and the upper limit must be at or below 2.500. F_hi has probability 0.05 to its right and gives the lower limit of the interval, and F_lo has probability 0.95 to its right and gives the upper limit. The test is the one-sided F test of the guidance read through this interval. It adds to the test of means in HE-FM-BIO-003, which uses only the reference variance.

Signature

r_s = s_WT / s_WR; L_r = r_s / sqrt(F_hi); U_r = r_s / sqrt(F_lo); BE_r = (U_r <= delta_r)
Inputs
InputsDefinitionUnit
s_WTEstimated within-subject standard deviation of the log measure for the test productnatural log units
s_WREstimated within-subject standard deviation of the log measure for the reference product, above 0natural log units
F_hiValue of the F distribution with v_1 numerator and v_2 denominator degrees of freedom with probability 0.05 to its rightdimensionless
F_loValue of the F distribution with v_1 numerator and v_2 denominator degrees of freedom with probability 0.95 to its rightdimensionless
delta_rLimit for the upper confidence limit of the ratio, 2.500 in Appendix Fratio
Output
r_sTest within-subject standard deviation divided by the reference oneratio
L_rLower limit of the 90% interval for the ratioratio
U_rUpper limit of the 90% interval for the ratioratio
BE_rEquals 1 (true) when U_r is at or below delta_r and 0 (false) otherwisebinary indicator

Function

Two one-sided tests and scaled limits function for bioequivalence

Maps a study's difference in log means, its standard error and the reference product's within-subject variability to the statistics behind a bioequivalence decision. It takes d, SE, t_crit and a pair of acceptance limits to the two one-sided t statistics, the reference coefficient of variation to the EMA widened limits for Cmax, the reference within-subject variance to the FDA reference-scaled upper bound, and two within-subject standard deviations to the FDA upper limit for their ratio. The 90% interval for the ratio is HE-FM-ANDA-001, the rounded check against 80.00% to 125.00% is HE-VT-ANDA-001, the crossover standard error is HE-FM-ANDA-002 and the post-entry generic price is HE-FM-ANDA-003; these live records are cited and not repeated. Notation follows the Bioequivalence article.

Try this function

Implementations

  • Excel

    Standard deviation ratio interval in named cells

    With the inputs in cells named SDTest, SDRef, DFTest and DFRef, the six formulas return, in order, cells named SDRatio, FQuantileHigh, FQuantileLow, LowerSDRatio, UpperSDRatio and SDRatioPassed. A blank SDRef returns #DIV/0! and a blank degrees of freedom cell returns #NUM!.

    =SDTest/SDRef; =F.INV.RT(0.05,DFTest,DFRef); =F.INV.RT(0.95,DFTest,DFRef); =SDRatio/SQRT(FQuantileHigh); =SDRatio/SQRT(FQuantileLow); =IF(UpperSDRatio<=2.5,1,0)

Assumptions

  • Standard deviation ratio degrees of freedom

    v_1 and v_2 are the degrees of freedom of s_WT and s_WR, as Appendix F step 4 defines them. In a fully replicate TRTR and RTRT study each product's estimate has n minus m degrees of freedom, by the same form as the s_WR formula in Appendix F step 1 (derived). The worked examples type the quantiles as inputs.

  • Alpha of 0.1 in the printed interval

    Appendix F sets alpha to 0.1 in the 100(1 minus alpha)% interval, so each tail is 0.05. Section III.B and Appendix F apply the comparison to narrow therapeutic index drugs, alongside HE-FM-BIO-003 and the unscaled limits.

Worked examples

  • Test product slightly less variable than the reference

    Illustrative fully replicate study with 34 degrees of freedom for each estimate, s_WT of 0.09 and s_WR of 0.10. The interval is 0.6761 to 1.1981, so the upper limit is below 2.500.

    s_WT = 0.09; s_WR = 0.10; F_hi = 1.77207; F_lo = 0.56431; delta_r = 2.5; r_s = 0.9; L_r = 0.6761; U_r = 1.1981; BE_r = 1
  • Test product more than twice as variable as the reference

    Illustrative study with the same degrees of freedom, s_WT of 0.22 and s_WR of 0.10. The estimated ratio of 2.2 is below 2.500, but the upper limit of 2.9286 is above it, so the comparison fails.

    s_WT = 0.22; s_WR = 0.10; F_hi = 1.77207; F_lo = 0.56431; delta_r = 2.5; r_s = 2.2; L_r = 1.6527; U_r = 2.9286; BE_r = 0
  • Equal variability in a small study

    A limiting case with illustrative inputs. With equal estimates and 10 degrees of freedom for each, the ratio is 1, and the limits are 0.5795 and 1.7258, whose product is 1 (derived).

    s_WT = 0.10; s_WR = 0.10; F_hi = 2.97824; F_lo = 0.33577; delta_r = 2.5; r_s = 1; L_r = 0.5795; U_r = 1.7258; BE_r = 1

Common errors

  • Swapping the two F quantiles

    F_hi belongs to the lower limit. Dividing by the square root of F_hi to obtain the upper limit in the second worked example gives 1.6527, which passes 2.500, when the true upper limit of 2.9286 fails.

  • Dropping the square root

    The interval is for a ratio of standard deviations and the F quantile belongs to the ratio of variances. Without the square root the first worked example gives 1.5949 in place of 1.1981.

  • Comparing the point estimate with 2.500

    The condition is on the upper limit of the interval. In the second worked example the estimated ratio of 2.2 is below 2.500 while the upper limit is 2.9286, so the point estimate alone would pass a study that fails.

Sources

  • FDA guidance on the within-subject variability comparison

    US Food and Drug Administration, Center for Drug Evaluation and Research. Statistical Approaches to Establishing Bioequivalence: Guidance for Industry. Silver Spring, MD: FDA; May 2026. Section III.B, the one-sided F test of the ratio of within-subject standard deviations with limit delta, and Appendix F steps 4 and 5, the 100(1 minus alpha)% interval with F quantiles having probability alpha/2 and 1 minus alpha/2 to the right, alpha of 0.1, and the upper limit at or below 2.500.

    View source →

Canonical Identity

Stable URI · Machine-readable · Resolvable · CC BY 4.0

This formula is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/formula/fda-interval-for-the-ratio-of-within-subject-standard-deviations

FDA interval for the ratio of within-subject standard deviations | HealthEconomics.wiki