EMA widened acceptance limits for Cmax of a highly variable product

The EMA guideline lets the acceptance range for Cmax widen with the reference product's within-subject variability, as exp(minus k s_WR) and exp(k s_WR) with k of 0.760, to a maximum of 69.84% to 143.19%, while the point estimate stays inside 80.00% to 125.00%. The first step solves the coefficient of variation equation of HE-IM-ANDA-002 for the within-subject standard deviation; the guideline's table footnote prints the same equation. The min and max keep the limits at L_0 and U_0 where no widening is allowed and at the cap at a coefficient of variation of 50% and above, a form written here from the guideline's conditions and table (derived). GMR, GMR_L and GMR_U are the outputs of HE-FM-ANDA-001.

Signature

s_WR = sqrt(log(1 + CV_WR^2)); s_cap = sqrt(log(1 + CV_cap^2)); s_use = min(s_WR, s_cap); L_w = min(L_0, exp(-k * s_use)); U_w = max(U_0, exp(k * s_use)); BE_w = (GMR_L >= L_w) and (GMR_U <= U_w) and (GMR >= L_0) and (GMR <= U_0)
Inputs
InputsDefinitionUnit
CV_WRWithin-subject coefficient of variation of Cmax for the reference product, as a proportionproportion
CV_capCoefficient of variation at which widening stops, 0.50 in the guideline's tableproportion
L_0Conventional lower limit, 0.80ratio
kRegulatory constant, 0.760 in the guidelinedimensionless
U_0Conventional upper limit, 1.25ratio
GMR_LLower limit of the 90% interval for the ratio, from HE-FM-ANDA-001ratio
GMR_UUpper limit of the 90% interval for the ratio, from HE-FM-ANDA-001ratio
GMRGeometric mean ratio of test to reference for Cmax, from HE-FM-ANDA-001ratio
Output
s_WRWithin-subject standard deviation of log-transformed Cmax for the reference productnatural log units
s_capValue of s_WR at the coefficient of variation where widening stopsnatural log units
s_useThe smaller of s_WR and s_capnatural log units
L_wLower acceptance limit for the ratio after widening, at most L_0ratio
U_wUpper acceptance limit for the ratio after widening, at least U_0ratio
BE_wEquals 1 (true) when the interval lies inside L_w and U_w and the point estimate inside L_0 and U_0, and 0 (false) otherwisebinary indicator

Function

Two one-sided tests and scaled limits function for bioequivalence

Maps a study's difference in log means, its standard error and the reference product's within-subject variability to the statistics behind a bioequivalence decision. It takes d, SE, t_crit and a pair of acceptance limits to the two one-sided t statistics, the reference coefficient of variation to the EMA widened limits for Cmax, the reference within-subject variance to the FDA reference-scaled upper bound, and two within-subject standard deviations to the FDA upper limit for their ratio. The 90% interval for the ratio is HE-FM-ANDA-001, the rounded check against 80.00% to 125.00% is HE-VT-ANDA-001, the crossover standard error is HE-FM-ANDA-002 and the post-entry generic price is HE-FM-ANDA-003; these live records are cited and not repeated. Notation follows the Bioequivalence article.

Try this function

Implementations

  • Excel

    EMA widened limits and verdict in named cells

    With the inputs in cells named CVRef, CVCap, RegulatoryK, StandardLower, StandardUpper, RatioEstimate, LowerRatio and UpperRatio, the six formulas return, in order, cells named RefWithinSD, CapWithinSD, UsedWithinSD, WidenedLower, WidenedUpper and WidenedPassed. Enter CVRef as a proportion. A blank CVRef is treated as 0, so the limits stay at the conventional values and no error appears.

    =SQRT(LN(1+CVRef^2)); =SQRT(LN(1+CVCap^2)); =MIN(RefWithinSD,CapWithinSD); =MIN(StandardLower,EXP(-RegulatoryK*UsedWithinSD)); =MAX(StandardUpper,EXP(RegulatoryK*UsedWithinSD)); =IF(AND(LowerRatio>=WidenedLower,UpperRatio<=WidenedUpper,RatioEstimate>=StandardLower,RatioEstimate<=StandardUpper),1,0)

Assumptions

  • Replicate study with a justified and prespecified widening

    Section 4.1.10 of the guideline requires a replicate design that demonstrates a within-subject variability for Cmax of the reference above 30%, a sound clinical justification that a wider difference in Cmax is clinically irrelevant, and a request specified prospectively in the protocol. The applicant also justifies that the variability estimate is reliable and does not result from outliers.

  • Cmax only, with AUC held at the conventional range

    The guideline does not apply the widening to AUC, whose acceptance range stays at 80.00% to 125.00% regardless of variability. For AUC the standard check of HE-VT-ANDA-001 applies.

  • Limits at the conditions of the guideline's table

    The raw formula at a coefficient of variation of 30% gives 0.80003 and 1.24995, which the guideline's table prints as 80.00 and 125.00; the min and max return 0.80 and 1.25 there and below (derived). The raw formula first reaches 1.25 at a coefficient of variation of about 30.005%, so the form agrees with the table at each of its five rows. BE_w compares unrounded values, while the guideline's rounding sentence in section 4.1.8 is written for 80.00% to 125.00%, so a limit at the edge of that range can read differently once rounded (derived).

Worked examples

  • Replicate study at a reference coefficient of variation of 40%

    At an illustrative coefficient of variation of 40% the limits are 74.62% to 134.02%, as in the guideline's table. An illustrative interval of 78% to 111% around a ratio of 93% passes, though its lower limit would fail the 80.00% rule.

    CV_WR = 0.40; CV_cap = 0.50; k = 0.760; L_0 = 0.80; U_0 = 1.25; GMR = 0.93; GMR_L = 0.78; GMR_U = 1.11; s_WR = 0.385253; s_cap = 0.472381; s_use = 0.385253; L_w = 0.7462; U_w = 1.3402; BE_w = 1
  • Widening stops at the cap for a coefficient of variation of 60%

    At an illustrative coefficient of variation of 60% the standard deviation is 0.554513, above the value at the cap, so the limits stay at 69.84% to 143.19%, the maximum in section 4.1.10. An illustrative interval of 72% to 122% passes.

    CV_WR = 0.60; CV_cap = 0.50; k = 0.760; L_0 = 0.80; U_0 = 1.25; GMR = 0.94; GMR_L = 0.72; GMR_U = 1.22; s_WR = 0.554513; s_cap = 0.472381; s_use = 0.472381; L_w = 0.6984; U_w = 1.4319; BE_w = 1
  • No widening below a coefficient of variation of 30%

    A limiting case with illustrative inputs. At a coefficient of variation of 25% the conventional limits stay, so an interval with a lower limit of 78% fails.

    CV_WR = 0.25; CV_cap = 0.50; k = 0.760; L_0 = 0.80; U_0 = 1.25; GMR = 0.95; GMR_L = 0.78; GMR_U = 1.16; s_WR = 0.246221; s_cap = 0.472381; s_use = 0.246221; L_w = 0.80; U_w = 1.25; BE_w = 0
  • Point estimate outside the conventional range despite wide limits

    At an illustrative coefficient of variation of 45% the limits are 72.15% to 138.59%, and an illustrative interval of 117% to 138% lies inside them, but the ratio of 127% is above 125.00%, so the study fails on the point estimate.

    CV_WR = 0.45; CV_cap = 0.50; k = 0.760; L_0 = 0.80; U_0 = 1.25; GMR = 1.27; GMR_L = 1.17; GMR_U = 1.38; s_WR = 0.429421; s_cap = 0.472381; s_use = 0.429421; L_w = 0.7215; U_w = 1.3859; BE_w = 0

Common errors

  • Widening the limits for AUC

    The widening is for Cmax only. At a coefficient of variation of 40% an AUC interval with a lower limit of 78% would pass a widened 74.62% limit, while the guideline keeps AUC at 80.00% and the study fails.

  • Typing the coefficient of variation as a percentage

    CVRef is a proportion. Typing 40 in place of 0.40 gives a standard deviation of 2.716, above the cap, so the cell silently returns 69.84% to 143.19% in place of 74.62% to 134.02%.

  • Using the raw formula below 30%

    The formula alone narrows the range at low variability, to 82.93% to 120.58% at a coefficient of variation of 25%. Section 4.1.10 uses it to widen the range for a reference above 30%, and the conventional limits stay in place otherwise.

  • Scaling on a variability other than the reference product's

    Section 4.1.10 scales on the within-subject standard deviation of the reference product. With an illustrative reference at 32% and test at 45%, the correct limits are 78.88% to 126.78%, while scaling on the test product gives 72.15% to 138.59%.

Sources

  • EMA guideline section on highly variable products

    European Medicines Agency, Committee for Medicinal Products for Human Use. Guideline on the investigation of bioequivalence. CPMP/EWP/QWP/1401/98 Rev. 1/Corr. Adopted 20 January 2010, in effect 1 August 2010. Section 4.1.10, Highly variable drugs or drug products. [U, L] = exp[plus or minus k sWR] with k set to 0.760 and sWR the within-subject standard deviation of log-transformed Cmax of the reference product; the table of limits at within-subject coefficients of variation of 30, 35, 40, 45 and 50% with its footnote on the coefficient of variation; a maximum of 69.84 to 143.19%; the geometric mean ratio within 80.00 to 125.00%; AUC not widened; replicate design, justification and prospective request.