Correlation of baseline and final values and an imputed standard deviation of change

A meta-analysis of mean differences in change from baseline needs each arm's standard deviation of change for V_MD in HE-FM-MEAD-001, and so for the weights in HE-FM-ADMA-001, and reports often leave it out. Where a donor group reports the standard deviations at baseline, at the final visit and of the change, the first part gives their correlation. The second part takes a correlation, from that calculation or from elsewhere, and imputes the standard deviation of change for a target group that reports only baseline and final values. HE-FM-AR1-004 takes the same form for a variance only when both visits share one variance and the correlation follows AR(1) (the agreement is derived); here the two standard deviations may differ and the correlation is entered directly. The function sqrt is the square root.

Signature

Corr_D = (SD_bD^2 + SD_fD^2 - SD_cD^2) / (2 * SD_bD * SD_fD); SD_c = sqrt(SD_b^2 + SD_f^2 - 2 * Corr * SD_b * SD_f)
Inputs
InputsDefinitionUnit
SD_bDStandard deviation at baseline in the group that reports all three, above zerooutcome units
SD_fDStandard deviation at the final visit in the group that reports all three, above zerooutcome units
SD_cDStandard deviation of change from baseline in the group that reports all threeoutcome units
SD_bStandard deviation at baseline in the target group, above zerooutcome units
SD_fStandard deviation at the final visit in the target group, above zerooutcome units
CorrCorrelation applied to the target group, from Corr_D, an average of donor values, another source or reasoned argument, at least -1 and at most 1correlation
Output
Corr_DCorrelation between baseline and final values implied by the donor group's three standard deviationscorrelation
SD_cImputed standard deviation of change from baseline in the group that lacks itoutcome units

Function

Mean difference between two groups and the study summaries behind its analysis

Maps the means, standard deviations and sizes of two groups on one continuous scale to the mean difference and its standard error, the pair that an inverse-variance meta-analysis takes for each study, and recovers or checks the summaries a report leaves out. The pooled mean difference is HE-FM-ADMA-001 with y_i equal to the study's mean difference and v_i equal to its squared standard error, and heterogeneity and random-effects pooling are HE-FM-ADMA-002 to HE-FM-ADMA-005, all run from estimates and standard errors by HE-CF-ADMA-001. A confidence interval is HE-FM-AN-001, and a standard error read back from a reported interval is that record solved for SE, the form HE-FM-HR-007 gives on the log scale. Differences in mean cost and mean QALYs enter the ratio HE-FM-ICER-001 and the net benefit records HE-FM-NMB-002 and HE-FM-AN-004. Dividing by a pooled standard deviation in place of leaving natural units gives Cohen's d, HE-FM-CD-001. Notation follows the Mean Difference article.

Try this function

Implementations

  • Excel

    Donor correlation and imputed standard deviation of change in named Excel cells

    With the inputs in cells named SdBaselineDonor, SdFinalDonor, SdChangeDonor, CorrUsed, SdBaselineTarget and SdFinalTarget, the two formulas go in cells named CorrDonor and SdChangeImputed. CorrUsed may be a typed value or a reference to CorrDonor.

    =(SdBaselineDonor^2+SdFinalDonor^2-SdChangeDonor^2)/(2*SdBaselineDonor*SdFinalDonor); =SQRT(SdBaselineTarget^2+SdFinalTarget^2-2*CorrUsed*SdBaselineTarget*SdFinalTarget)

Assumptions

  • Imputed correlation used sparingly and varied in a sensitivity analysis

    The Handbook says the imputation should be used sparingly, because one can never be sure that an imputed correlation is appropriate. Correlations usually fall with the time between measurements and depend on the outcome, the participants and the intervention effect. It calls for a sensitivity analysis over different values of Corr.

  • Correlation below 0.5 favours post-intervention values over change

    The Handbook states that when a correlation below 0.5 is obtained there is little benefit in using change from baseline, and an analysis of post-intervention measurements will be more precise. With equal baseline and final standard deviations, the standard deviation of change falls below them exactly when Corr is above 0.5 (derived, 0 mismatches on a grid).

  • Substituting one visit's standard deviation for the other

    Where a baseline or final standard deviation is missing, the Handbook allows the other to stand in, as long as it is reasonable to assume the intervention does not alter the variability of the outcome.

  • Correlation values that keep the imputed standard deviation real

    With Corr at least -1 and at most 1 the expression under the root cannot be negative (derived). A Corr above 1 can make it negative, and Excel then returns #NUM!. Donor inputs that give Corr_D outside that range are inconsistent and point to a reporting error.

Worked examples

  • Cochrane Handbook example with an imputed correlation of 0.80

    The donor is the experimental group of the Handbook's first study, with standard deviations 6.4, 7.1 and 4.5 and a correlation of 0.78. Averaging with the comparator group's 0.82 gives the Handbook's 0.80, which it applies to the comparator group of a second study, with 4.0 and 4.4, to give 2.68.

    SD_bD = 6.4; SD_fD = 7.1; SD_cD = 4.5; Corr_D = 0.7826; Corr = 0.8; SD_b = 4; SD_f = 4.4; SD_c = 2.683
  • Comparator donor and the experimental group of the second Cochrane study

    The Handbook's comparator donor has standard deviations 7.0, 6.9 and 4.2 and a correlation of 0.82. The Handbook works only the comparator group of its second study. The value for the experimental group, with 4.2 and 3.8, at Corr of 0.80 is computed here.

    SD_bD = 7; SD_fD = 6.9; SD_cD = 4.2; Corr_D = 0.8175; Corr = 0.8; SD_b = 4.2; SD_f = 3.8; SD_c = 2.558
  • Correlation of zero returns the root of the summed variances

    Limiting case with the Handbook's second study. No correlation between visits gives the root of 16 plus 19.36, which is larger than either visit's standard deviation, and at this value the Handbook would prefer post-intervention values (HE-AS-MEAD-008).

    SD_bD = 6.4; SD_fD = 7.1; SD_cD = 4.5; Corr_D = 0.7826; Corr = 0; SD_b = 4; SD_f = 4.4; SD_c = 5.946

Common errors

  • Dropping the factor of 2 from the imputed standard deviation of change

    Leaving out the 2 in the second study's comparator group gives the root of 35.36 less 14.08, about 4.613, in place of 2.683, about 72% too large (computed here), and a smaller weight for that trial.

  • Carrying a correlation across very different follow-up times

    The Handbook warns that correlations usually fall as the time between measurements grows. For the second study's comparator group, a correlation of 0.5 in place of 0.8 gives about 4.214 in place of 2.683, a variance of change about 2.47 times larger (computed here), so a value borrowed from a shorter study overstates that trial's weight.

Sources

  • Cochrane Handbook on imputing standard deviations for changes from baseline

    Higgins JPT, Li T, Deeks JJ (editors). Chapter 6: Choosing effect measures and computing estimates of effect. In: Higgins JPT, Thomas J, Chandler J, Cumpston M, Li T, Page MJ, Welch VA (editors). Cochrane Handbook for Systematic Reviews of Interventions version 6.5. Cochrane; 2024. Section 6.5.2.8, part (1) on calculating Corr_E from the baseline, final and change standard deviations, with the values 0.78 and 0.82 and their average of 0.80, and the statements on values below 0.5; part (2) on imputing the standard deviation of change with the example value 2.68, the sensitivity analysis and the substitution of one visit's standard deviation for the other. The opening text says the methods in part (2) should be used sparingly and cites Follmann et al 1992 and Abrams et al 2005 for the technique.

    View source →

Canonical Identity

This formula is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/formula/correlation-of-baseline-and-final-values-and-an-imputed-standard-deviation-of-change

Correlation of baseline and final values and an imputed standard deviation of change | HealthEconomics.wiki