Signature
z_cap = z * SE_1 / sqrt(SE_1^2 + SE_2^2); P_cap = 2 * Phi_cap - 1
| Inputs | Definition | Unit |
|---|---|---|
z | Standard normal critical value of the first study's interval, 1.96 for a 95% interval | none |
SE_1 | Standard error of the estimate whose interval is being read, on the scale of the analysis | unit of the estimate, above 0 |
SE_2 | Standard error of the other study's estimate, on the same scale | unit of the estimate, at least 0 |
Phi_cap | Standard normal distribution function at z_cap, entered from NORM.S.DIST(z_cap, TRUE) or pnorm(z_cap) | probability |
z_cap | Half-width of the first interval divided by the standard deviation of the difference between the two estimates | none |
|---|---|---|
P_cap | Probability, over repeated pairs of studies, that the first study's interval holds the second study's estimate | probability |
Function
Reading and reusing reported confidence intervals
Takes the standard errors behind two reported intervals, or a reported estimate with its two-sided P value, and the critical value of the level in use, and returns three things a reader needs when working from published results. These are the chance that one study's interval holds another study's estimate, the false positive rate of judging a difference by whether two intervals overlap with the interval level that would restore a chosen test level, and a standard error and interval for a result reported with a P value alone. Building an interval is already live and is not repeated here. HE-FM-AN-001 gives the Wald interval from an estimate and its standard error, HE-FM-BINOM-005 the Wald interval for a proportion, HE-FM-HR-006 the log-scale interval for a hazard ratio, HE-FM-HR-007 the standard error recovered from a reported interval for a log hazard ratio, HE-FM-AN-002 and HE-FM-AN-003 the delta-method and Fieller intervals for an ICER, and HE-FM-AN-004 the interval for incremental net benefit, whose variance across paired bootstrap replicates is HE-FM-BSE-003. The z statistic for a difference between two independent estimates has the form of the third part of HE-FM-NMA-003. Notation follows the Confidence Interval article.
Try this function
Implementations
Excel
Excel capture probability from two standard errors
With the critical value in a cell named CritValue and the standard errors in StdErrFirst and StdErrSecond, the two formulas return the standardised half-width in a cell named ZCapture and the probability in CaptureProb. NORM.S.DIST is available from Excel 2010. With StdErrFirst and StdErrSecond both blank or zero, ZCapture returns #DIV/0!.
=CritValue*StdErrFirst/SQRT(StdErrFirst^2+StdErrSecond^2); =2*NORM.S.DIST(ZCapture,TRUE)-1
Assumptions
Two independent unbiased normal estimates of one quantity
The two estimates are independent, unbiased and normally distributed around one true value, the conditions Greenland and colleagues state for the 83% figure. A bias that differs between the two studies, or a real difference between their settings, lowers the probability below P_cap, for any size of shift (derived and checked on a grid of 1,568 cases). The standard errors are treated as known, and with small samples and estimated standard errors the normal form is only approximate (derived).
Probability averaged over both studies and not over the observed interval
P_cap averages over the sampling error of the first study as well as the second, so it describes the process before either study is seen (derived). Once an interval has been observed, the chance depends on where it happens to sit around the true value, which is unknown. The figure is a statement about the method, as the 95% is in the article.
Symmetric interval on the scale of analysis for capture
The first interval is a symmetric Wald interval, HE-FM-AN-001, on the scale on which the estimate is normal. A ratio measure is read on the natural log scale, with SE_1 and SE_2 the standard errors of the log ratios, as HE-FM-HR-007 recovers them.
Worked examples
Two studies of equal precision at the 95% level
The case Greenland and colleagues give. Two independent unbiased studies have the same standard error, so the 95% interval from the first holds the estimate from the second about 83% of the time. The result does not depend on the size of the common standard error (derived).
z = 1.96; SE_1 = 1; SE_2 = 1; z_cap = 1.3859; Phi_cap = 0.91712; P_cap = 0.8342
Second study with twice the standard error of the first
Illustrative inputs. A second study with a quarter of the patients has about twice the standard error, since a standard error usually falls with the square root of the sample size, and the first study's 95% interval holds its estimate about 62% of the time.
z = 1.96; SE_1 = 0.1; SE_2 = 0.2; z_cap = 0.8765; Phi_cap = 0.80963; P_cap = 0.6193
Second estimate with no sampling error returns the coverage
A limiting case that checks an implementation. With SE_2 at zero the second estimate is the true value itself, and P_cap returns the coverage of the interval, 95%.
z = 1.96; SE_1 = 1; SE_2 = 0; z_cap = 1.96; Phi_cap = 0.975; P_cap = 0.95
Common errors
Reading 95% as the share of future estimates inside the interval
Greenland and colleagues list this among the misreadings of an interval. For two studies of equal precision the figure is about 83%, and for a second study with twice the standard error about 62% (derived). A reader who expects 95% of replications inside the interval will take ordinary sampling variation as a failure to replicate.
Swapping the standard errors of the two studies
SE_1 belongs to the study whose interval is being read. With standard errors of 0.1 and 0.2, the narrow interval holds the noisy estimate 62% of the time and the wide interval holds the precise estimate 92% of the time, so a swap moves the answer by 30 percentage points (derived).
Adding the standard errors in place of their squares
The standard deviation of a difference between independent estimates is the square root of the sum of the squared standard errors. Writing z SE_1 / (SE_1 + SE_2) for equal standard errors gives z_cap of 0.98 and a probability of 0.6729 in place of 0.8342 (derived).
Applying the capture probability to one observed interval
P_cap is an average over first studies. For equal standard errors at the 95% level, a first estimate that happens to fall on the true value gives its interval a 95% chance of holding the second estimate, and a first estimate 1.96 standard errors from the true value gives about a 50% chance (derived). An observed interval does not reveal which case applies.
Sources
Greenland and colleagues on future estimates and an observed interval
Greenland S, Senn SJ, Rothman KJ, Carlin JB, Poole C, Goodman SN, Altman DG. Statistical tests, P values, confidence intervals, and power: a guide to misinterpretations. European Journal of Epidemiology. 2016;31(4):337-350. Section Common misinterpretations of confidence intervals, numbered item 22. It states that under ideal conditions the chance that a future estimate falls within the current interval is usually much less than 95%, and that for two independent studies with unbiased normal estimates and the same standard errors the chance that the 95% interval of the first contains the estimate of the second is 83%, which it describes as the chance that the difference between the two estimates is less than 1.96 standard errors. The form with unequal standard errors is derived from that statement and is not printed there.
Canonical Identity
Stable URI · Machine-readable · Resolvable · CC BY 4.0
