Concept Architecture
Executable Model in Health Technology Assessment
When a company submits a health economic model, the written report describes the model and the executable copy is the model itself, in the software it was built in and ready to run. The difference matters because a reviewer can read a report but can only test a model by running it. Eddy and colleagues, in the ISPOR-SMDM Task Force 7 report, note that it is virtually impossible to judge a model's accuracy by "running" it in one's head, and that even the full code does not help a reader without the time and resources to implement it. In health technology assessment, the executable copy is therefore where much of the checking of a submitted model happens.
What makes a model executable
A model is executable when the person who receives it can open it, change its inputs and regenerate its results without rebuilding anything. NICE PMG36 (2022, updated 2026), section 5.5.15, accepts fully executable economic models in standard software, which it lists as Excel, DATA/Treeage, R or WinBUGs. A company planning to use other software must tell NICE in advance, so that NICE and the External Assessment Group can decide whether it is acceptable. A company submitting a fully executable electronic copy must give NICE full access to the programming code, and should make sure the submitted model and the written evidence submission match.
A model that runs may still be closed to inspection. The TECH-VER checklist of Büyükkaramikli and colleagues asks for a fully accessible electronic model without hidden or locked parts, and its completeness test looks for hidden sheets, ranges or modules, links to other software, hard-coded values and password protection before any calculation is tested. Feenstra and colleagues say validation is helped by access to the code or to a spreadsheet executable with any attached code, such as Visual Basic for Applications macros. In general software usage an executable is a compiled file that runs without showing its code, and NICE separately requires full access to the programming code. In simulation science the nearest term is the computerised model, which Sargent defines as the conceptual model implemented on a computer and which is checked in computerised model verification before operational validity is assessed on it.
Eddy and colleagues also describe a lighter form of access, in which readers specify inputs and receive outputs without a full copy being released. Kent and colleagues give the SHARP CKD-CVD model as an open-access example of a user interface of this kind. Such an interface supports some checks of model behaviour but does not let a reviewer trace a formula.
Verification and validation on a working copy
Verification asks whether the model was built right, and validation asks whether it is the right model for the decision. An executable copy serves both in different ways, and keeping them apart shows what the copy can and cannot settle.
For technical verification, the working copy is a precondition. TECH-VER needs a model reviewer, preferably independent, an executable and transparent model, its input sources and detailed documentation. Its tests run in order, starting with black-box testing against prior expectations, then white-box testing line by line or cell by cell for key calculations and for unexpected black-box results, and replication only when the first two leave unexpected results unexplained. The CADTH tool of Coyle and colleagues, which Abraham and colleagues call the CDA-AMC Model Validation Tool, asks in item 26 that the deterministic result and the results of single Monte Carlo simulations can be accessed, and in item 27 for a clear trace linking all input parameters to final outcomes. Coyle and colleagues say that if a model is not sufficiently transparent, the necessary testing may not be feasible and the model cannot be considered as demonstrating validity.
For model validation, the working copy lets a reviewer set the inputs to match a real study, such as a clinical trial, and compare the outputs with what was observed, while reruns such as a scenario analysis with a different extrapolation or the probabilistic sensitivity analysis with a corrected distribution mainly explore uncertainty. AdViSHE, the validation-assessment tool of Vemer and colleagues, asks developers reporting cross validity whether their comparisons rest on published outcomes only or on access to the alternative model. Running a model under the company's own inputs shows only what the model does, so external validation against observed data is still needed to show whether it predicts well.
Who receives the executable model and on what terms
Access to the working copy is often controlled, because models are costly to build and may hold confidential data. Eddy and colleagues recommend that modellers give full technical documentation, with access to a working copy, to readers designated by a journal or by a decision-making organisation, under agreements that protect intellectual property. Modellers who make working copies available should be credited with an exceptionally high level of transparency, but failing to do so should not prejudice the evaluation of the model.
| Setting | Who gets the executable model | Terms |
|---|---|---|
| NICE technology appraisal, PMG36 sections 5.4.13, 5.5.15 and 5.5.16 | NICE and its External Assessment Group, and stakeholders on request | Full access to programming code for NICE; stakeholders sign a confidentiality agreement, run the model only to test its reliability and delete it once final guidance is published |
| Institute for Clinical and Economic Review (ICER) evidence reviews, model transparency statement | Manufacturers, when there is enough interest, during public comment on the draft report | A fee to ICER's academic collaborators (none for models built by ICER staff); confidentiality or licensing agreements, limited time, no right to alter the model |
| Journal publication, CHEERS 2022 | Editors and reviewers | Sharing models with editors and reviewers in a form that is not locked is encouraged; item 16 asks whether the model is publicly available and where |
The NICE route is the most demanding, since a company that submits a model must give NICE full access to its programming code, and NICE may ask the company to redact confidential material in the copy given to stakeholders if this does not severely limit the model's function. ICER's default is different. Executable models and code are not part of its standard deliverable, to protect the intellectual property of its external collaborators, and it publishes instead a modelling analysis plan intended to let an experienced researcher replicate the model. Corro Ramos and colleagues name the NICE External Assessment Groups as an example of independent validators without conflicts of interest, and such a group works on the executable submission as well as the written evidence.
Worked example of a test that needs the executable copy
All numbers in this example are illustrative. A company submits a three-cycle Markov cohort model with two states, alive and dead. The written report states an annual probability of death of 0.10 on standard care and 0.08 on the new treatment, a utility of 0.75 for the alive state in both arms, no discounting and an incremental cost of GBP 4,000. Without half-cycle correction, and counting the cohort at the end of each cycle, QALYs per person are
where is the QALYs per person, is the utility of the alive state, is the annual probability of death, is the cycle number and is the number of cycles (3).
1. Standard care, as reported. The survivors are 0.9, 0.81 and 0.729, which sum to 2.439. QALYs are 0.75 × 2.439 = 1.82925.
2. New treatment, as reported. The survivors are 0.92, 0.8464 and 0.778688, which sum to 2.545088. QALYs are 0.75 × 2.545088 = 1.908816.
3. The ratio the report implies. Incremental QALYs are 1.908816 − 1.82925 = 0.079566, and the incremental cost-effectiveness ratio is 4,000 / 0.079566 = GBP 50,273 per QALY gained. The submission instead states GBP 30,659. In a real model the report alone gives no way to find the source of such a gap.
4. Equal-effectiveness test on the executable copy. In a black-box test, the reviewer sets the new treatment's probability of death to 0.10, so both arms should give 1.82925 QALYs. The copy returns 1.87803 for the new treatment, and 1.87803 − 1.82925 = 0.04878, which is 0.02 × 2.439. A white-box check of the QALY formula finds the alive-state utility typed into the new treatment arm as 0.77 instead of linked to the 0.75 input cell.
5. Recomputing the submitted result. With the hard-coded value, new treatment QALYs are 0.77 × 2.545088 = 1.959718, incremental QALYs are 1.959718 − 1.82925 = 0.130468, and 4,000 / 0.130468 = GBP 30,659, which reproduces the submitted figure. Linking the cell to the input restores GBP 50,273.
This is a verification finding, because the model does not match its report, and it says nothing about whether the model suits the decision. The gap showed up in a hand check against the report, but its cause was found only by running the copy and then reading its formulas.
Limits and common misreadings
An executable copy widens what a reviewer can check. The sources still warn against overstating its value.
- Running is not understanding. Feenstra and colleagues note that even full code does not guarantee transparency, since without well-structured documentation many models may still be seen as black boxes by external users. A model whose workings cannot be inspected is a black box model however freely it runs.
- Running is not validity. Corro Ramos and colleagues observe that open-source modelling software promotes transparency but does not replace the need for model validation.
- Sharing has costs. Eddy and colleagues point out that providing access can be very expensive, including building the copy, its interfaces and the support needed for accurate use.
- Redaction may not protect confidential inputs. ICER warns that recipients may sometimes back-calculate redacted inputs, and its licensing agreements prohibit back-calculation through what-if queries or other methods.
- An executable copy is not open source. Executable submissions are usually confidential, while an open-source model makes its code public. Open-Source Model, Model Transparency, Model Documentation and Model Replication have their own entries.
Sources
- Abraham K, Corro Ramos I, Braal CL, et al. Under-reporting of validation efforts for health economic models persists despite the availability of validation tools: a systematic review. PharmacoEconomics. 2025;43:849-858. https://doi.org/10.1007/s40273-025-01491-2
- Büyükkaramikli NC, Rutten-van Mölken MPMH, Severens JL, Al M. TECH-VER: a verification checklist to reduce errors in models and improve their credibility. PharmacoEconomics. 2019;37(11):1391-1408. https://doi.org/10.1007/s40273-019-00844-y
- Corro Ramos I, Feenstra T, Ghabri S, Al M. Evaluating the validation process: embracing complexity and transparency in health economic modelling. PharmacoEconomics. 2024;42:715-719. https://doi.org/10.1007/s40273-024-01364-0
- Coyle D, Haines A, Lee K. The development of a model validation tool to assist in the conduct of economic evaluations. Canadian Journal of Health Technologies. 2024;4(3). https://doi.org/10.51731/cjht.2024.862
- Eddy DM, Hollingworth W, Caro JJ, Tsevat J, McDonald KM, Wong JB. Model transparency and validation: a report of the ISPOR-SMDM Modeling Good Research Practices Task Force-7. Value in Health. 2012;15(6):843-850. https://doi.org/10.1016/j.jval.2012.04.012
- Feenstra T, Corro-Ramos I, Hamerlijnck D, van Voorn G, Ghabri S. Four aspects affecting health economic decision models and their validation. PharmacoEconomics. 2022;40:241-248. https://doi.org/10.1007/s40273-021-01110-w
- Husereau D, Drummond M, Augustovski F, et al. Consolidated Health Economic Evaluation Reporting Standards 2022 (CHEERS 2022) statement: updated reporting guidance for health economic evaluations. BMJ. 2022;376:e067975. https://doi.org/10.1136/bmj-2021-067975
- Institute for Clinical and Economic Review. Statement of ICER's commitment to economic model transparency. Web page, undated, accessed 11 November 2026. https://icer.org/our-approach/methods-process/manufacturer-engagement/statement-of-icers-commitment-to-economic-model-transparency/
- Kent S, Becker F, Feenstra T, et al. The challenge of transparency and validation in health economic decision modelling: a view from Mount Hood. PharmacoEconomics. 2019;37:1305-1312. https://doi.org/10.1007/s40273-019-00825-1
- National Institute for Health and Care Excellence. NICE technology appraisal and highly specialised technologies guidance: the manual (PMG36). Published 31 January 2022, last updated 13 October 2026. Sections 5.4.13, 5.5.15 and 5.5.16. https://www.nice.org.uk/process/pmg36
- Sargent RG. Verification and validation of simulation models. In: Proceedings of the 2011 Winter Simulation Conference. 2011:183-198. https://www.informs-sim.org/wsc11papers/016.pdf
- Vemer P, Corro Ramos I, van Voorn GAK, Al MJ, Feenstra TL. AdViSHE: a validation-assessment tool of health-economic models for decision makers and model users. PharmacoEconomics. 2016;34:349-361. https://doi.org/10.1007/s40273-015-0327-2
Related Concepts (3)
Frequently Asked Questions (6)
What is Executable Model?
An executable model is a working electronic copy of a health economic model, such as an Excel or R file, that reviewers can rerun with changed inputs.
Source: NICE PMG36 (2022, updated 2026)
What does NICE require when a company submits an executable model for a technology appraisal?
Section 5.5.15 of NICE PMG36 (2022, updated 2026) accepts fully executable economic models built in standard software, which it lists as Excel, DATA/Treeage, R or WinBUGs. A company that submits a fully executable electronic copy must give NICE full access to the programming code and should make sure the model and the written evidence submission match. Under section 5.4.13 the model is made available on request to stakeholders who have signed a confidentiality agreement. Section 5.5.16 allows them to run it only to test its reliability and requires them to delete it once final guidance is published. NICE may also ask the company to redact the model where this does not severely limit its function.
Source: NICE PMG36 (2022, updated 2026)
Why do HTA reviewers need an executable model as well as the company's written report?
A report describes a model, while the executable copy can be rerun and its formulas traced. Eddy and colleagues, in the ISPOR-SMDM Task Force 7 report, note that it is virtually impossible to judge a model's accuracy by running it in one's head, and that providing the code does not help a reader without the time and resources to implement it. An error such as a utility typed into one arm instead of linked to its input cell can move the incremental cost-effectiveness ratio a long way while nothing in the report shows where the error lies. A reviewer finds that kind of gap by changing inputs in the working copy and then reading the formulas behind the result.
Source: Eddy et al. 2012
What does the TECH-VER checklist require of an executable model before verification begins?
The TECH-VER checklist of Büyükkaramikli and colleagues needs a model reviewer, preferably independent, an executable and transparent model, its input sources and detailed documentation. The electronic model should be fully accessible, without hidden or locked parts. Its completeness test looks for hidden sheets, ranges or modules, links to external programs, hard-coded values and password protection before any calculation is checked. Black-box tests against prior expectations follow, then white-box testing line by line or cell by cell for key calculations and for unexpected black-box results, with replication kept for unexpected results that white-box testing cannot explain. A copy that runs but hides sheets or locks its code falls short at the completeness test.
Source: Büyükkaramikli et al. 2019
Does running an executable model show that a health economic model is valid?
Running the copy under the company's own inputs shows only what the model does, which bears on verification, the question of whether the model was built right. Validation asks whether it is the right model for the decision, and that needs comparison with other evidence, such as external validation, in which the model simulates a real study and its predictions are compared with the observed outcomes. Reruns such as a scenario analysis or a corrected probabilistic sensitivity analysis mainly explore uncertainty. Coyle and colleagues, in the CADTH model validation tool, add that if a model is not sufficiently transparent the necessary testing may not be feasible, and the model cannot be considered as demonstrating validity.
Source: Coyle et al. 2024
On what terms do modellers usually share an executable model with reviewers?
Access is often controlled, because building a model can take a significant investment of time and money. Eddy and colleagues recommend that modellers give full technical documentation, with access to a working copy, to readers designated by a journal or by a decision-making organisation, under agreements that protect intellectual property. Modellers who do so should be credited with an exceptionally high level of transparency, but failing to do so should not prejudice the evaluation of the model. Providing access can be very expensive, since it covers building the copy and its interfaces and the support needed for accurate use. A lighter option lets readers specify inputs and receive outputs without a full copy being released.
Source: Eddy et al. 2012
Trust Record
Verified by Dr Darrin Baines
British health economist
Professional identity: darrinbaines.org
Verification date: 12 Nov 2026
Content version: 1.0.0
Canonical Identity
- Persistent URI
- https://healtheconomics.wiki/concept/executable-model
- Term code
- HE-EM-MV-125
Stable URI · Machine-readable · Resolvable · CC BY 4.0
