Emission Factor

An emission factor is an estimate of greenhouse gas emitted per unit of activity, such as kg CO2e per kWh or km, used to turn health care use into carbon.

Status
Published, version 1.0.0
Last reviewed
14 Nov 2026, by Dr Darrin Baines
Report a problem
Tell us if something is wrong or out of date

Concept Architecture

Emission Factor in Health Care Carbon Estimates

An emission factor does for carbon what a unit cost does for money in a costing study. An analyst counts an activity, such as kilowatt hours of electricity or kilometres of patient travel, and multiplies each count by its factor to obtain greenhouse gas emissions in kilograms of carbon dioxide equivalent (kg CO2e). Health economists meet emission factors when a trial, a care pathway or a decision model reports carbon next to costs and quality-adjusted life years, and the result depends on the factor set and boundary chosen. UK government tables publish these coefficients as greenhouse gas conversion factors, a sense unrelated to the conversion factor that turns relative value units into payments in US fee schedules.

Who uses the term emission factor

The label matches the literature. The term belongs to emissions inventories and carbon reporting rather than to health economics, and health care studies borrow it with its meaning unchanged.

  • The 2006 IPCC Guidelines for National Greenhouse Gas Inventories describe the most common simple method as combining activity data (AD) with coefficients that quantify emissions per unit of activity, called emission factors (EF), so that emissions equal AD times EF.
  • Griffiths and colleagues, for the Low Carbon Clinical Trials Group, sourced emission factors to convert activity data into greenhouse gas emissions for every activity in two clinical trials funded by Cancer Research UK.
  • Misrai and colleagues define an emission factor as a coefficient that allows activity data to be converted into greenhouse gas emissions, and apply factors to the weighed raw materials of disposable surgical devices.

The UK Department for Energy Security and Net Zero (DESNZ) publishes the official UK set each year, and its methodology paper treats emission factors as one kind of conversion factor, next to calorific values.

Activity data multiplied by emission factors

Every carbon estimate built from the bottom up rests on one multiplication, repeated for each activity and summed. The activity data carry the quantity, and the factor the emissions per unit.

E=∑k=1KAk×EFkE = \sum_{k=1}^{K} A_k \times EF_k

where EE is the total emissions in kg CO2e, AkA_k is the activity data for activity kk in its own unit (kWh, km, kg of material or GBP spent), EFkEF_k is the emission factor for activity kk in kg CO2e per unit, and KK is the number of activities counted.

Gases other than carbon dioxide enter through global warming potentials. The DESNZ 2026 factors express methane and nitrous oxide as CO2e using values from the fifth IPCC assessment report, 28 for methane and 265 for nitrous oxide. The factors are also grouped by scope, with Scope 1 for sources an organisation owns or controls, Scope 2 for purchased energy such as electricity and Scope 3 for other indirect emissions such as business travel.

Misrai and colleagues dismantled seven disposable devices for transurethral prostate surgery, weighed each piece by raw material and multiplied each weight by a factor in kg CO2e per kg from the French public database Base Carbone. Plastic was the most common material and the least emissive, at 2.38 kg CO2e per kg, and the embodied footprints ranged between 0.07 and 3.3 kg CO2e per device.

Physical, spend-based and upstream factors

Health care studies draw on two families of factor, and the right one depends on what the activity data measure. Whether upstream emissions are included is a further choice within either family.

Physical factors give emissions per unit of a measured quantity. In the DESNZ 2026 set, UK grid electricity is 0.13096 kg CO2e per kWh (Scope 2) and an average car of unknown fuel type is 0.16591 kg CO2e per km.

Spend-based factors give emissions per unit of money spent on a category of goods or services. The DESNZ factors are activity-based, and its methodology paper notes that the spend-based multipliers Defra publishes suit users without enough activity data, and that users should report the methods they used. Tennison and colleagues combined both kinds for the NHS in England, multiplying expenditure in each of 424 sectors of an input-output model by that sector's emission factor for the supply chain and using UK government factors for building energy.

Upstream factors add the emissions of producing and delivering a fuel. DESNZ calls these well-to-tank emissions, classes them as Scope 3 and publishes them separately, for example 0.04399 kg CO2e per km for an average car of unknown fuel type.

Why emission factors change between editions

Emission factors are estimates from a named dataset for a given year and place, and they are revised. Matching the factor to the activity is part of the analysis.

DESNZ publishes a new set each year, and the 2026 factors are for activity data that fall entirely or mostly within 2026. The UK grid electricity factor fell from 0.177 kg CO2e per kWh in the 2025 set to 0.13096 in the 2026 set, and (0.177 − 0.13096) ÷ 0.177 = 0.26, a fall of about 26% in one edition. The fall coincides with a change of method, since the 2026 set replaced data that arrived with a two-year lag by more recent energy statistics, because the older factor did not reflect the recent carbon intensity of a fast decarbonising grid. The data year jumped forward, with no 2024 data year, so the two editions are not a like-for-like series.

Source and geography matter as well. Griffiths and colleagues chose freely available factors, mainly from Ecoinvent version 2.2 and the UK government conversion factors, and noted that more suitable or more recent factors may exist behind paid subscriptions. Misrai and colleagues warned that their French factors might not be accurate for other countries.

Emission factors in economic evaluation and HTA

In an economic evaluation, emission factors attach to the same resource use counts that unit costs value. The step mirrors cost valuation, with kg CO2e per unit in place of GBP per unit, so a model that already counts visits, bed days and trips can report emissions with little extra structure.

Smith and colleagues used per unit carbon emissions to report the footprint of smoking cessation support per QALY gained, and included the social cost of carbon in their cost-effectiveness analysis. Marsh and colleagues, after adding carbon dioxide to a type 2 diabetes model, called for resource-specific environmental impacts to improve its accuracy. In a paper on health technology assessment, McAlister and colleagues noted a scarcity of carbon footprint data for health care interventions.

Inside a model, an emission factor enters as a parameter input and carries parameter uncertainty like any other. Tennison and colleagues could not run a full uncertainty analysis for their hybrid model, and cited earlier work finding a relative standard error of about 4% to 6% for total UK consumer emissions from the input-output model. A scenario analysis that swaps factor sets or boundaries shows how far the carbon result depends on these choices.

Worked example with remote follow-up and patient travel

All activity numbers in this example are illustrative, and the emission factors are the DESNZ values quoted above. A service replaces two of four yearly clinic visits with remote monitoring. Each clinic visit means a 30 km round trip by an average car of unknown fuel type, and the remote equipment uses 20 kWh of grid electricity per patient per year. The travel factor is 0.16591 direct plus 0.04399 well-to-tank, or 0.2099 kg CO2e per km. The electricity factor is the Scope 2 generation factor alone, so steps 1 to 4 put travel on a wider boundary than electricity. Adding the 2026 Scope 3 factors for transmission and distribution losses (0.01299) and electricity well-to-tank (0.03682 and 0.00359) would raise it to 0.18436 kg CO2e per kWh and cut the saving by 20 × (0.18436 − 0.13096) = 1.068 kg CO2e.

1. Usual care. 4 × 30 = 120 km, and 120 × 0.2099 = 25.188 kg CO2e per patient per year.

2. Remote service. 2 × 30 = 60 km, and 60 × 0.2099 = 12.594 for travel. Electricity adds 20 × 0.13096 = 2.6192, so the remote arm emits 12.594 + 2.6192 = 15.2132 kg CO2e.

3. Difference. 25.188 − 15.2132 = 9.9748, a saving of about 10 kg CO2e per patient per year.

4. Older electricity factor. With the 2025 factor of 0.177, electricity is 20 × 0.177 = 3.54, the remote arm emits 12.594 + 3.54 = 16.134, and the saving is 25.188 − 16.134 = 9.054 kg CO2e.

5. Direct factors only. Without well-to-tank emissions, usual care emits 120 × 0.16591 = 19.9092, travel in the remote arm is 60 × 0.16591 = 9.9546, the remote arm emits 9.9546 + 2.6192 = 12.5738, and the saving is 19.9092 − 12.5738 = 7.3354 kg CO2e.

6. Equipment manufacture. If the equipment carries an embodied footprint of 5 kg CO2e per patient per year, the remote arm emits 15.2132 + 5 = 20.2132 and the saving is 25.188 − 20.2132 = 4.9748 kg CO2e.

7. Interpretation. The saving stays between about 5 and 10 kg CO2e per patient, and the boundary choices in steps 5 and 6 move it more than the factor year in step 4, so a report should state the factor source, year and boundary.

Emission factors beside carbon footprint and unit cost

An emission factor is a per-unit coefficient. Carbon Footprint, which has its own entry, is the total obtained by applying factors to activity.

Unit cost is the money counterpart of an emission factor, and both multiply the same resource counts. When a study values emissions in money, as Smith and colleagues did, it treats them as a negative externality that falls on third parties.

In RHEO

RHEO represents an emission factor as an estimate used in economic evaluation, the class emission factor estimate, RHEO_0000105, giving the greenhouse gas emissions caused by one unit of a kind of resource or care process in kg CO2e, so spend-based factors per unit of money spent in a sector fall outside the class. An emissions record in RHEO names the emission factor estimate it applies, so the factor and the emissions it yields stay separate. RHEO is a formal ontology published at healtheconomics.wiki/ontologies/rheo.

Common errors when choosing and applying emission factors

Most errors come from treating a factor as a fixed constant rather than an estimate with a source, year and boundary. Three recur in health care work.

  1. Mixing factor years. The UK grid electricity factor fell by about 26% between the 2025 and 2026 sets, so factors should match the year of the activity data.
  2. Mixing boundaries. In the worked example, dropping well-to-tank emissions cuts the saving by more than 2 kg CO2e per patient.
  3. Counting the same emissions twice. Tennison and colleagues removed Scope 1 and 2 categories from their input-output results because bottom-up calculations already covered them.

Sources

Library

Publications

9
  • Journal article

    Incorporating carbon into health care: adding carbon emissions to health technology assessments — McAlister S, Morton RL, Barratt A, Vol. 6, No. 12, pp. e993-e999 ed., 2022 (The Lancet Planetary Health)

    Journal article held for the HealthEconomics.wiki concept pages on Emission Factor and Carbon Footprint, where it is the listed source.

  • Journal article

    Incorporating environmental outcomes into a health economic model — Marsh K, Ganz M, Nørtoft E, Lund N, Graff-Zivin J, Vol. 32, No. 6, pp. 400-406 ed., 2016 (International Journal of Technology Assessment in Health Care)

    Journal article held for the HealthEconomics.wiki concept pages on Emission Factor and Carbon Footprint, where it is the listed source.

  • Journal article

    A standardized method for estimating the carbon footprint of disposable minimally invasive surgical devices: application in transurethral prostate surgery — Misrai V, Rijo E, Cottenceau JB, et al, Vol. 2, No. 3, Article e094 ed., 2021 (Annals of Surgery Open)

    Journal article named as the provenance of the HealthEconomics.wiki concept page on Emission Factor.

  • Journal article

    Quantifying the carbon footprint of clinical trials: guidance development and case studies — Griffiths J, Fox L, Williamson PR; Low Carbon Clinical Trials Group, Vol. 14, No. 1, Article e075755 ed., 2024 (BMJ Open)

    Journal article held for the HealthEconomics.wiki concept pages on Emission Factor and Carbon Footprint, where it is the listed source or definition source of a mapped RHEO class.

  • Journal article

    Health care's response to climate change: a carbon footprint assessment of the NHS in England — Tennison I, Roschnik S, Ashby B, et al, Vol. 5, No. 2, pp. e84-e92 ed., 2021 (The Lancet Planetary Health)

    Journal article held for the HealthEconomics.wiki concept pages on Emission Factor and Carbon Footprint, where it is the page provenance or listed source.

  • Journal article

    The carbon footprint of behavioural support services for smoking cessation — Smith AJ, Tennison I, Roberts I, Cairns J, Free C, Vol. 22, No. 5, pp. 302-307 ed., 2013 (Tobacco Control)

    Journal article held for the HealthEconomics.wiki concept pages on Emission Factor and Carbon Footprint, where it is the listed source.

  • Report

    2026 Government Greenhouse Gas Conversion Factors for Company Reporting: Methodology Paper for Conversion Factors, Final Report — Department for Energy Security and Net Zero, 2026 (DESNZ)

    Report listed in the Sources of the HealthEconomics.wiki concept page on Emission Factor.

  • Guidance

    2006 IPCC Guidelines for National Greenhouse Gas Inventories — Intergovernmental Panel on Climate Change, 2006 (IGES)

    Guidance document listed in the Sources of the HealthEconomics.wiki concept page on Emission Factor.

  • Other

    Greenhouse gas reporting: conversion factors 2026 (flat file, revised July 2026) and conversion factors 2025 (flat file) — Department for Energy Security and Net Zero, 2025 (DESNZ)

    Source listed in the Sources of the HealthEconomics.wiki concept page on Emission Factor.

Frequently Asked Questions (6)

  • What is Emission Factor?

    An emission factor is an estimate of greenhouse gas emitted per unit of activity, such as kg CO2e per kWh or km, used to turn health care use into carbon.

    Source: Misrai et al. 2021

  • How is an emission factor used to estimate the carbon footprint of health care?

    An emission factor is multiplied by activity data, the counted quantity of an activity, and the products are summed across activities to give emissions in kg CO2e. Misrai and colleagues applied this formula to disposable devices for transurethral prostate surgery, weighing each raw material and multiplying the weight by a factor in kg CO2e per kg from the French Base Carbone database. Plastic was the most common material and the least emissive at 2.38 kg CO2e per kg, and the embodied footprints ranged between 0.07 and 3.3 kg CO2e per device.

    Source: Misrai et al. 2021

  • Why did the UK grid electricity emission factor change between 2025 and 2026?

    The UK government publishes a new set of greenhouse gas conversion factors each year, and the grid electricity emission factor fell from 0.177 kg CO2e per kWh in the 2025 set to 0.13096 in the 2026 set, a drop of about 26%. The 2026 methodology paper explains that the older method relied on emissions data with a two-year lag, so the factor did not reflect the recent carbon intensity of a fast decarbonising grid, and the change of method means the two sets are not a like-for-like series. The 2026 factors are meant for activity data falling entirely or mostly within 2026, so analysts should match the factor year to the activity year.

    Source: DESNZ 2026

  • How do physical and spend-based emission factors differ in health care carbon accounting?

    A physical emission factor gives emissions per unit of a measured quantity, such as a kWh of electricity or a km driven, while a spend-based factor gives emissions per unit of money spent in an economic sector. The carbon footprint of the NHS in England used both kinds in a hybrid model, multiplying expenditure in 424 sectors of an input-output model by sector emission factors for the supply chain and using UK government factors for building energy. Scope 1 and 2 categories were removed from the input-output results because bottom-up calculations already covered them, which avoided counting the same emissions twice.

    Source: Tennison et al. 2021

  • How can emission factors be added to a health economic model?

    Emission factors attach to the same resource use counts that unit costs value, so a model that already counts visits, bed days and trips can report carbon in kg CO2e next to costs and QALYs. Each factor enters the model as a parameter input with its own uncertainty, and a scenario analysis that swaps factor sets or boundaries shows how far the carbon result depends on those choices. Marsh and colleagues added carbon dioxide emissions to an existing model of type 2 diabetes over 30 years from the UK payer perspective, and called for resource-specific environmental impacts to improve the accuracy of the approach.

    Source: Marsh et al. 2016

  • What are well-to-tank emissions in a UK emission factor for travel?

    Well-to-tank emissions are the upstream emissions of extracting, refining and delivering a fuel before it is used, and the UK government conversion factors class them as Scope 3 and publish them separately from the direct factor. For an average car of unknown fuel type, the 2026 direct factor is 0.16591 kg CO2e per km and the well-to-tank factor adds 0.04399, giving 0.2099 kg CO2e per km in total. A patient travel estimate that leaves out the upstream factor will report lower emissions for the same trips, so the boundary should be stated with the result.

    Source: DESNZ 2026

Trust Record

Verified by Dr Darrin Baines

British health economist

Professional identity: darrinbaines.org

Verification date: 14 Nov 2026

Content version: 1.0.0

Canonical Identity

Term code
HE-EM-MP-049

Stable URI · Machine-readable · Resolvable · CC BY 4.0

This article is licensed under Creative Commons Attribution 4.0 International (CC BY 4.0).

Author: Dr Darrin Baines · Publisher: Intelligent Parameters Ltd · Identifier: https://healtheconomics.wiki/concept/emission-factor