Concept Architecture
Common Cause Variation and Telling Routine Noise from Real Change in Health Service Performance
Common cause variation is the movement in a health service measure, such as monthly readmissions or a hospital's mortality rate, that occurs even when nothing about the way care is delivered has changed. Health economists need the concept because payments, sanctions and improvement effort are often directed by comparing such measures, and acting on noise spends resources without changing outcomes.
Shewhart's constant system of chance causes
Shewhart (1931) set out the idea, developed in the production of telephone equipment at Bell Telephone Laboratories. He treated any unknown cause of a phenomenon as a chance cause, and he called a phenomenon controlled when past experience allows a prediction, at least within limits, of how it will vary in future. A controlled quality, in his words, "must be a variable quality".
He postulated that constant systems of chance causes exist, meaning the probability distribution of the measured characteristic does not change over time, and that other causes, which he called assignable, may be found and eliminated. He described maximum control as the state in which fluctuations come from a constant system of a large number of chance causes, none with a predominating effect, and held that there is a limit beyond which it is not economically feasible to go in trying to eliminate chance fluctuations. NHS guidance (NHS Improvement 2019) uses the terms common cause for this expected variation and special cause for unusual variation, and links the classification to the type of action required, which in some cases is none.
The ideas reached health care through statistical process control. Benneyan, Lloyd and Plsek (2003) describe the problem it addresses, which is that repeated measurements of a care process naturally differ, so a later measurement can suggest better or worse performance even if nothing was done. Mohammed and colleagues (2001) applied Shewhart's approach to six case studies, including the excess deaths after paediatric cardiac surgery in Bristol and the activities of Harold Shipman, as a basis for clinical governance.
Why the line between noise and signal is an economic choice
Shewhart framed the choice of limits in economic terms. Wider limits mean fewer searches for trouble that does not exist, while narrower limits catch real trouble more often. He wrote of striking a balance between the cost of looking for trouble when it does not exist and the losses from overlooking trouble that does exist, and concluded that experience indicated three standard deviations as an acceptable economic value.
Here is the expected number of false alarms, is the number of observations examined while the process is stable, and is the probability that an observation produced only by common causes falls inside the limits. Under a normal distribution approximation, is about 0.9973 for limits at three standard deviations and 0.95 for limits at 1.96 standard deviations.
The false alarm is a type I error and the missed change a type II error, and each has a resource cost. Investigating a result that is common cause variation uses staff time with an opportunity cost and improves nothing. NHS Improvement (2019) calls such overreaction tampering, and notes that when a target lies outside the process limits, reacting to each rise or fall will not improve performance and will waste time and resources.
How control limits mark out common cause variation
A control chart estimates the range of common cause variation from the data and flags observations outside it. The centre line is the process average and, following Shewhart, the limits sit about three standard deviations of the plotted statistic on either side. NHS Improvement (2019) notes that users do not set the limits, which follow from the variability of the measure.
For an indicator that is a proportion, such as the share of patients readmitted, the limits for a provider or period with patients around a reference proportion are as follows.
Here is the pair of lower and upper limits for unit , is the reference proportion, is the number of patients in unit and the square root term is the standard deviation of an observed proportion under the binomial distribution. Limits widen as falls, so a small provider can show a high rate that is still common cause variation. Mohammed, Worthington and Woodall (2008) give a tutorial on constructing the main chart types for healthcare data.
Before charting, differences in patients that can be measured should be removed by risk adjustment for case mix.
League tables, payment and the cost of chasing noise
Ranking providers turns common cause variation into an apparent quality gradient. Adab and colleagues (2002) pointed out that in a league table someone must come bottom, and that providers recognise their ranking as almost entirely decided by chance. With 95% confidence intervals, about 5% (1 in 20) of providers in a stable system will always be identified as outliers, whereas control charts, in their account, use the equivalent of a 99.8% confidence level, close to the 99.7% of limits at three standard deviations. They cited evidence that performance rankings had been used in hiring, firing, disciplining and paying bonuses to staff.
Their redrawing of myocardial infarction mortality data for 37 very large acute hospitals in England shows the difference. The league table placed one hospital at the highest mortality, but on the control chart its result fell within the limits and could reasonably be attributed to common cause variation, while another hospital, which readers of the league table did not pick out, lay outside the limits. Adab and colleagues add that changing any single component cannot reduce the noise of a stable system, and that once special causes have been dealt with, the only way to improve the quality of care is to change the entire system.
Marshall, Mohammed and Rouse (2004) tested the effect on decisions in a randomised trial. Directors of public health in 122 UK health authorities were sent three case studies showing mortality by provider, as league tables or as control charts, and 57 returned the questionnaire. Those given league tables would act on significantly more providers in each case study, at 3.3% against 1.8%, 15.9% against 6.7%, and 5.9% against 0.7%. The authors concluded that control charts would reduce over-investigation of unusual performance.
For benchmarking and performance-related payment, a bonus or penalty that depends on rank within the common cause band transfers money by chance and tells providers nothing about what to change.
Common cause variation in economic evaluation and decision models
Decision modelling has its own vocabulary for the same idea. Briggs and colleagues (2012), for the ISPOR-SMDM task force, distinguish stochastic uncertainty, the random variability in outcomes between identical patients, from parameter uncertainty and from heterogeneity, the variability between patients that can be attributed to their characteristics. Common cause variation in a service indicator can be read as the aggregate of stochastic variability among patients treated by one stable system, while case-mix differences correspond to heterogeneity and belong in the adjustment.
The distinction matters when routine data are used as evidence. A before-and-after comparison of a service change that moves an indicator within its common cause limits gives weak evidence of an effect, so an economic evaluation built on that change risks crediting costs and benefits to noise. When indicators vary between providers by more than chance alone would produce, Spiegelhalter (2005) showed that ignoring this over-dispersion can classify many institutions as abnormal, and judged that an additive random effects model, which treats some between-provider variation as part of the expected spread, appears to have the stronger conceptual foundation; the UK Healthcare Commission adopted the method for its star ratings.
Worked example with five hospitals and one readmission indicator
All figures in this example are illustrative. A commissioner compares 30-day readmission proportions for five hospitals against a reference proportion of = 0.10, after case-mix adjustment, using limits at three standard deviations.
Step 1 is to compute each hospital's limits. With = 0.09, the standard deviation of the observed proportion is .
| Hospital | Patients | Readmissions | Proportion | Standard deviation | Limits | z-score |
|---|---|---|---|---|---|---|
| A | 100 | 16 | 0.160 | 0.030 | 0.010 to 0.190 | 2.0 |
| B | 400 | 48 | 0.120 | 0.015 | 0.055 to 0.145 | 1.3 |
| C | 900 | 81 | 0.090 | 0.010 | 0.070 to 0.130 | -1.0 |
| D | 2,500 | 190 | 0.076 | 0.006 | 0.082 to 0.118 | -4.0 |
| E | 3,600 | 450 | 0.125 | 0.005 | 0.085 to 0.115 | 5.0 |
For hospital A, = 0.03, so the limits are 0.10 ± 0.09, and its z-score is . For hospital E, = 0.005, the limits are 0.10 ± 0.015 and the z-score is .
Step 2 is to compare the ranking with the chart. A league table orders the hospitals D (7.6%), C (9.0%), B (12.0%), E (12.5%) and A (16.0%), placing A last. The chart says A, B and C lie within common cause variation, while E lies above its upper limit and D below its lower limit, so only D and E show special cause signals.
Step 3 is to size the excess. Hospital E would expect 0.10 × 3,600 = 360 readmissions and records 450, an excess of 90. At an illustrative GBP 3,000 per readmission that is GBP 270,000. Hospital A records 16 against an expected 10, an excess of 6 worth GBP 18,000, but this is within the range a stable system produces for 100 patients. Hospital D records 60 fewer than expected, a special cause signal worth investigating as practice to learn from or as a recording problem.
Step 4 is to count false alarms across a stable system. Suppose 100 trusts all run the same stable process. With limits at 1.96 standard deviations, trusts flagged by chance each round. With limits at three standard deviations, . At an illustrative GBP 5,000 per investigation the expected cost of false alarms is GBP 25,000 against GBP 1,350 a round.
The hospital ranked worst is not the one where investigation pays, and the choice of limits sets how much is spent chasing noise.
Boundaries with nearby concepts
Common cause variation is one of two kinds of variation in Shewhart's scheme and contrasts with special cause variation, which has an identifiable source outside the stable system; statistical process control separates them. Process capability asks a different question, namely whether a stable process meets a required standard. Thor and colleagues (2007) quote the warning that statistical control does not equate with clinical control, and NHS Improvement (2019) notes that a target outside the process limits cannot be expected to be met without changing the process.
Warranted and unwarranted variation, the categories used for clinical practice variation, ask a different question again, namely whether differences in care are justified by patients' needs and informed preferences. A provider can sit inside common cause limits on an outcome indicator while its practice pattern is unwarranted, and a special cause signal does not by itself show that care was poor.
Limitations and common misreadings
A result inside the limits does not prove that the system is stable. Shewhart himself noted that a value falling within the range is not sufficient to prove that the sample came from a constant system. Limits for small providers are wide, as for hospital A, so real differences can be hidden, and limits for very large providers are narrow, so trivial differences become signals.
The classification depends on the statistical model. Inadequate risk adjustment turns heterogeneity into apparent special causes, while over-dispersion handled by a random effects model absorbs some real between-provider differences into the common cause band. Treating a stable process as acceptable is a further error, because a process can be predictable and consistently poor. The remedy for unacceptable common cause variation is redesign of the system, whose cost and effect belong in the same economic appraisal as any other intervention.
Sources
- Shewhart WA. Economic control of quality of manufactured product. New York: D. Van Nostrand Company; 1931.
- Benneyan JC, Lloyd RC, Plsek PE. Statistical process control as a tool for research and healthcare improvement. Quality and Safety in Health Care 2003;12(6):458-464. doi:10.1136/qhc.12.6.458.
- Mohammed MA, Cheng KK, Rouse A, Marshall T. Bristol, Shipman, and clinical governance: Shewhart's forgotten lessons. Lancet 2001;357(9254):463-467. doi:10.1016/S0140-6736(00)04019-8.
- Thor J, Lundberg J, Ask J, Olsson J, Carli C, Pukk Härenstam K, Brommels M. Application of statistical process control in healthcare improvement: systematic review. Quality and Safety in Health Care 2007;16(5):387-399. doi:10.1136/qshc.2006.022194.
- NHS Improvement. Making data count: getting started. London: NHS Improvement; 2019. https://www.england.nhs.uk/wp-content/uploads/2019/12/making-data-count-getting-started-2019.pdf
- Mohammed MA, Worthington P, Woodall WH. Plotting basic control charts: tutorial notes for healthcare practitioners. Quality and Safety in Health Care 2008;17(2):137-145. doi:10.1136/qshc.2004.012047.
- Adab P, Rouse AM, Mohammed MA, Marshall T. Performance league tables: the NHS deserves better. BMJ 2002;324(7329):95-98. doi:10.1136/bmj.324.7329.95.
- Marshall T, Mohammed MA, Rouse A. A randomized controlled trial of league tables and control charts as aids to health service decision-making. International Journal for Quality in Health Care 2004;16(4):309-315. doi:10.1093/intqhc/mzh054.
- Briggs AH, Weinstein MC, Fenwick EAL, Karnon J, Sculpher MJ, Paltiel AD. Model parameter estimation and uncertainty: a report of the ISPOR-SMDM Modeling Good Research Practices Task Force-6. Value in Health 2012;15(6):835-842. doi:10.1016/j.jval.2012.04.014.
- Spiegelhalter DJ. Handling over-dispersion of performance indicators. Quality and Safety in Health Care 2005;14(5):347-351. doi:10.1136/qshc.2005.013755.
Related Concepts (3)
Library
Publications
8
Performance league tables: the NHS deserves better — Adab P, Rouse AM, Mohammed MA, Marshall T, Vol. 324, No. 7329, pp. 95-98 ed., 2002 (BMJ)
Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture articles on Common Cause Variation and control chart, where it is cited as a reference for that concept.
Journal ArticleView source →Bristol, Shipman, and clinical governance: Shewhart's forgotten lessons — Mohammed MA, Cheng KK, Rouse A, Marshall T, Vol. 357, No. 9254, pp. 463-467 ed., 2001 (Lancet)
Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Common Cause Variation, where it is cited as a reference for that concept.
Journal ArticleView source →Application of statistical process control in healthcare improvement: systematic review — Thor J, Lundberg J, Ask J, Olsson J, Carli C, Pukk Härenstam K, Brommels M, Vol. 16, No. 5, pp. 387-399 ed., 2007 (Quality and Safety in Health Care)
Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture articles on Common Cause Variation and control chart, where it is cited as a reference for that concept.
Journal ArticleView source →Economic control of quality of manufactured product — Shewhart WA, 1931 (D. Van Nostrand Company)
Book or book chapter listed in the Sources of the HealthEconomics.wiki Concept Architecture articles on Common Cause Variation and control chart, where it is cited as a reference for that concept.
BookPlotting basic control charts: tutorial notes for healthcare practitioners — Mohammed MA, Worthington P, Woodall WH, Vol. 17, No. 2, pp. 137-145 ed., 2008 (Quality and Safety in Health Care)
Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture articles on Common Cause Variation and control chart, where it is cited as a reference for that concept.
Journal ArticleView source →Statistical process control as a tool for research and healthcare improvement — Benneyan JC, Lloyd RC, Plsek PE, Vol. 12, No. 6, pp. 458-464 ed., 2003 (Quality and Safety in Health Care)
Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Common Cause Variation, where it is cited as a reference for that concept.
Journal ArticleView source →A randomized controlled trial of league tables and control charts as aids to health service decision-making — Marshall T, Mohammed MA, Rouse A, Vol. 16, No. 4, pp. 309-315 ed., 2004 (International Journal for Quality in Health Care)
Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture articles on Common Cause Variation and control chart, where it is cited as a reference for that concept.
Journal ArticleView source →Making data count: getting started — NHS Improvement, 2019 (NHS Improvement)
Source listed in the Sources of the HealthEconomics.wiki Concept Architecture articles on Common Cause Variation and control chart, where it is cited as a reference for that concept.
Frequently Asked Questions (6)
What is common cause variation?
Common cause variation is the routine variation a stable process produces from many small chance causes, predictable within limits from past data.
Source: Shewhart 1931
What normal random variation is common cause variation?
Common cause variation is the variation that results from the normal, inherent randomness within a stable system. It results from the ordinary fluctuations built into any process, not from anything unusual. It occurs within a stable system, one behaving as it always does, so the variation is expected rather than alarming. It differs from special cause variation, which arises from a specific, identifiable factor outside the system's normal workings. It is distinguished from special cause variation using a control chart, which separates routine noise from genuine change. The routine noise of a stable process is what it names. Shewhart (1931) set this out.
Source: Shewhart 1931
What does common cause variation result from?
Common cause variation results from normal, inherent randomness within a stable system, so it arises from the ordinary randomness built into a stable process, unlike special cause variation from a specific, identifiable factor. This origin in inherent randomness defines it. So common cause variation is variation resulting from normal, inherent randomness within a stable system, unlike special cause variation from a specific, identifiable factor This occurrence within a stable system is what marks common cause variation as the normal noise of that system.
Source: Shewhart 1931
Within what does common cause variation occur?
Common cause variation occurs within a stable system, so it is the variation from normal, inherent randomness in a stable process, unlike special cause variation from a specific, identifiable factor. This occurrence within a stable system defines it. So common cause variation is variation resulting from normal, inherent randomness within a stable system, unlike special cause variation from a specific, identifiable factor This difference in source is what separates common cause variation from special cause variation with a specific cause.
Source: Shewhart 1931
How does common cause variation differ from special cause variation?
Common cause variation differs from special cause variation in its source: common cause variation results from normal, inherent randomness within a stable system, while special cause variation comes from a specific, identifiable factor. So common cause variation is the ordinary noise of a stable process and special cause variation signals a particular cause, connected as contrasting kinds of variation. So common cause variation is inherent, not from a specific factor.
Source: Shewhart 1931
How does common cause variation relate to a control chart?
Common cause variation relates to a control chart as what the chart distinguishes: common cause variation is variation from normal, inherent randomness within a stable system, and a control chart is a statistical tool monitoring a process over time using control limits, distinguishing normal variation from a genuine, significant change. So a control chart separates common cause variation from special cause, connected as the ordinary variation and the tool that identifies it.
Source: Shewhart 1931
Trust Record
Not verified for this version
This concept changed after its last verification. Re-verify to stamp this version.
Canonical Identity
- Term code
- HS-NHS-HQ-018