Concept Architecture
Calibration Target in Health Economic Models
A calibration target is a piece of observed evidence, such as cancer incidence in a cancer registry or the prevalence found at a first screening round, that a health economic model has to reproduce once its unknown parameters are set. During calibration the analyst runs the model at candidate parameter values, sets each matching output beside its target and keeps the values whose outputs agree. Which targets are used, and how much weight each carries, decides which parameter values survive and therefore the costs, QALYs and ICER the model goes on to report, so reviewers in health technology assessment question target sets as they would any other evidence.
Observed outputs used for fitting, not as inputs
Stout and colleagues, reviewing calibration in cancer simulation models, define a target as observed data the model attempts to replicate during calibration, and add that target data are, by definition, not used as direct model inputs. A target can be a single summary statistic, such as mean age at cancer diagnosis, or a series, such as an age-specific incidence curve. In the articles they reviewed, targets came from cancer registries, observational studies and clinical trials, and most models were calibrated to several targets.
Targets are evidence on things the model produces. Menzies and colleagues give the example of programme data on the number of people starting treatment, an outcome related at once to the size of the population at risk, screening rates and the accuracy of the diagnostic tests. No single input can be read off such a figure, so the model has to be run to see which combinations of inputs reproduce it.
Choosing targets that pin down the parameters
Stout and colleagues note that the choice and number of targets may depend on data availability and quality, the number of parameters under calibration and model complexity. Too few targets, or targets that inform the same part of the model, can leave the problem nonidentifiable, so that several parameter sets fit equally well while implying different results.
Alarid-Escudero and colleagues, whose relative survival example the Calibration page sets out, found that a second target describing a different part of a Markov model made its two parameters identifiable. The authors suggest that targets informing different aspects of a model help. In a simulation study by Rutter and colleagues, a parameter governing the spread of the time from preclinical to clinical cancer in a hypothetical model was estimated with more than 130% bias from three calibration data sets and with 1.9% bias once a fourth data set on transition times was added.
More targets carry their own risk. Alarid-Escudero and colleagues warn that targets drawn from a population different from the one being modelled can bias the calibrated parameters, so such a target should represent the population of interest or be adjusted, for example through meta-analysis or bias analysis.
Turning observed data into a comparison
Menzies and colleagues describe calibration targets as mathematical functions that summarise the available evidence on modelled outcomes, which in their Bayesian tutorial are likelihoods. Where the way the data were generated is known, such as a simple random sample tested with a perfect test, the data give a binomial distribution likelihood directly. If the survey is instead scored with a normal approximation, the standard error of the proportion is
where is the standard error of the observed proportion, is the proportion positive and is the number of people sampled.
When only a published mean and confidence interval are available, Menzies and colleagues approximate the likelihood with a normal distribution whose spread comes from the width of the interval.
where is the standard error used for the target, is the upper limit of the 95% confidence interval and is the lower limit.
Uncertainty that is not sampling error needs separate handling. The Menzies tutorial treats programme data on treatment volume as subject to imperfect reporting and warns that ignoring non-sampling bias can make targets overly strong or biased. If the bias is poorly understood, the target may be weakened in line with a rough judgement of its size. If the source of bias is known, the observation process can be modelled, for example by fitting to test positivity, the true prevalence times sensitivity plus one minus the prevalence times one minus specificity, instead of to true prevalence.
Checking that each modelled output uses the same age band, period, outcome definition and denominator as its target is a verification task, part of technical verification. A mismatch can sit in the model specification as well as in the code, and no search algorithm will correct it, because the search absorbs it into parameter values that fit the wrong comparison.
Weighting several targets
With several targets the fit of each has to be combined. Enns and colleagues note that analysts often choose weights to compensate for differences in data quality, measurement scales and preferences for fitting some targets over others, and define the goodness of fit score as the weighted sum of individual fits. A common form weights each squared deviation by the target's precision.
where is the fit score of parameter set across targets, lower meaning closer, is the model output matched to target , is the target value and its standard error.
Kong and colleagues gave primary targets a weight of 1.0 and secondary targets 0.5 to avoid overfitting to targets with possible measurement issues or dissimilar populations. Enns and colleagues proposed avoiding weights by keeping the parameter sets on the Pareto frontier, an approach the Calibration page covers with the search methods.
Worked example with two targets and a weakened survey
All numbers in this example are illustrative. A natural history model of a disease with a preclinical phase is calibrated to two targets. Registry incidence is 120 per 100,000 a year with a 95% confidence interval of 110 to 130. A screening survey found 40 positives among 500 people, a prevalence of 8.0%.
1. Build the targets. The incidence standard error is (130 − 110) / 3.92 = 5.102 per 100,000. For the survey, 0.08 × 0.92 / 500 = 0.0001472, and its square root is 0.012133, so the standard error is 1.2133 percentage points.
2. Score two candidate parameter sets. Set A predicts incidence of 121 and prevalence of 6.0%. Set B predicts incidence of 126 and prevalence of 8.0%.
| Set | Incidence term | Prevalence term | |
|---|---|---|---|
| A | (1 / 5.102)² = 0.038 | (2.0 / 1.2133)² = 2.717 | 2.756 |
| B | (6 / 5.102)² = 1.383 | 0 | 1.383 |
Set B fits better, matching the survey and missing incidence by just over one standard error.
3. Weaken the survey target. Suppose the survey's sampling frame is poorly documented, so its bias is poorly understood and can only be roughly judged. Doubling its standard error to 2.4265 points, as an allowance for that bias, divides the prevalence term by four, so set A scores 0.0384 + 0.6793 = 0.718 while set B still scores 1.383. Set A now fits better.
4. Interpret. The same data and model give a different best-fitting set once one target is judged less trustworthy. The weighting decision is therefore part of the evidence, and a report should state the reason for it and show results under the original weighting as a scenario.
Calibration targets and model validation
Fitting to targets is part of building the model, while model validation asks whether the finished model is right for the decision. Eddy and colleagues, in the ISPOR-SMDM report on model transparency and validation, say calibration reporting should include the target, goodness-of-fit metric, search algorithm, acceptance criteria and stopping rule. They call a validation dependent when the same source was used both to estimate model parameters and to validate the model, and describe dependent validations as closely related to calibration. A model that reproduces its targets has therefore passed a dependent check only, the subject of the Dependent Validation page.
The same report calls a validation independent, the subject of the Independent Validation page, when no information from the source was used to build the model, so it needs a source kept out of calibration altogether. Data held back from a source already used as a target give at best a partially dependent validation, where the source was used to build or calibrate part of a model but that part does not by itself wholly determine the outcome being validated. The AdViSHE tool of Vemer and colleagues asks separately for comparison against the data sources on which the model is based (dependent validation) and against a source not used to build the model (independent validation), and lists calibration among the data adjustments whose description and justification should be given.
What reviewers look for
Stout and colleagues found that 83 of 87 articles discussing or citing calibration methods mentioned the data used as targets, while search algorithms, acceptance criteria and stopping rules were rarely described well. Their Calibration Reporting Checklist asks for the data, methods and sources behind the targets. Ghabri and colleagues report a pilot review of 77 manufacturers' cost-effectiveness analyses received by the French HAS between 2013 and 2017, which found a general lack of transparent documentation of attempts to adjust model parameters to fit known outcomes.
A reviewer such as an External Assessment Group can check a calibrated model by asking for the list of targets with their sources and populations, the uncertainty attached to each, the weights and their rationale, a plot of modelled against observed values for each target, and the data held back for validation. Results under alternative weights or target sets show how far the ICER rests on these choices.
Limits and common misreadings
A close fit to targets does not show that the model structure is right, because calibrated parameters can absorb structural error, the concern of structural uncertainty analysis. Menzies and colleagues regard perfect fit to a long list of outcomes as unreasonable for a model that simplifies reality, and warn that chasing it can produce overfitting and overconfident predictions.
In clinical prediction modelling, calibration means agreement between predicted risks and observed event rates, as in the Calibration Plot entry, with no target to fit. A calibration target is also distinct from the target population, the group of people a decision concerns.
Sources
- Alarid-Escudero F, MacLehose RF, Peralta Y, Kuntz KM, Enns EA. Nonidentifiability in model calibration and implications for medical decision making. Medical Decision Making. 2018;38(7):810-821. https://pmc.ncbi.nlm.nih.gov/articles/PMC6156799/
- Eddy DM, Hollingworth W, Caro JJ, Tsevat J, McDonald KM, Wong JB. Model transparency and validation: a report of the ISPOR-SMDM Modeling Good Research Practices Task Force-7. Value in Health. 2012;15(6):843-850. https://doi.org/10.1016/j.jval.2012.04.012
- Enns EA, Cipriano LE, Simons CT, Kong CY. Identifying best-fitting inputs in health-economic model calibration: a Pareto frontier approach. Medical Decision Making. 2015;35(2):170-182. https://pmc.ncbi.nlm.nih.gov/articles/PMC4277724/
- Ghabri S, Stevenson M, Möller J, Caro JJ. Trusting the results of model-based economic analyses: is there a pragmatic validation solution? PharmacoEconomics. 2019;37:1-6. https://doi.org/10.1007/s40273-018-0711-9
- Kong CY, McMahon PM, Gazelle GS. Calibration of disease simulation model using an engineering approach. Value in Health. 2009;12(4):521-529. https://pmc.ncbi.nlm.nih.gov/articles/PMC2889011/
- Menzies NA, Soeteman DI, Pandya A, Kim JJ. Bayesian methods for calibrating health policy models: a tutorial. PharmacoEconomics. 2017;35(6):613-624. https://pmc.ncbi.nlm.nih.gov/articles/PMC5448142/
- Rutter CM, Miglioretti DL, Savarino JE. Bayesian calibration of microsimulation models. Journal of the American Statistical Association. 2009;104(488):1338-1350. https://pmc.ncbi.nlm.nih.gov/articles/PMC2805837/
- Stout NK, Knudsen AB, Kong CY, McMahon PM, Gazelle GS. Calibration methods used in cancer simulation models and suggested reporting guidelines. PharmacoEconomics. 2009;27(7):533-545. https://pmc.ncbi.nlm.nih.gov/articles/PMC2787446/
- Vemer P, Corro Ramos I, van Voorn GAK, Al MJ, Feenstra TL. AdViSHE: a validation-assessment tool of health-economic models for decision makers and model users. PharmacoEconomics. 2016;34(4):349-361. https://doi.org/10.1007/s40273-015-0327-2
Related Concepts (2)
Frequently Asked Questions (6)
What is Calibration Target?
Calibration targets are observed data, such as registry incidence or survival, that a health economic model is fitted to when calibrating its parameters.
Source: Stout et al. 2009
How is a calibration target built from published data for a health economic model?
Menzies and colleagues describe calibration targets as mathematical functions that summarise the evidence on modelled outcomes, which in their Bayesian tutorial are likelihoods. Where the data come from a simple random sample tested with a perfect test, a binomial likelihood can be used directly. When only a published mean and 95% confidence interval are reported, the likelihood is approximated by a normal distribution whose standard error is the upper limit minus the lower limit, divided by 3.92. Data with non-sampling error, such as programme counts subject to imperfect reporting, need extra handling, because ignoring that bias can make a target overly strong or biased.
Source: Menzies et al. 2017
Why does the choice of calibration targets affect how well a health economic model's parameters are identified?
With too few targets, several parameter sets can fit the data equally well while implying different results, so the parameters are not identifiable. Rutter and colleagues showed the effect in a simulation study of Bayesian calibration for a hypothetical microsimulation model with precursor, preclinical and clinical cancer states. A parameter governing the spread of the time from preclinical to clinical cancer was estimated with more than 130% bias from three calibration data sets. Once a fourth data set on transition times was added, the bias fell to 1.9%. The added target helped because it described the transitions that the poorly estimated parameter controls.
Source: Rutter et al. 2009
How are several calibration targets weighted when fitting a health economic model?
Enns and colleagues note that analysts often choose weights to compensate for differences in data quality and measurement scales, and for a preference to fit some targets more closely than others. The goodness of fit score is then the weighted sum of the individual fits, so the weights decide which parameter sets rank highest. A common form divides each gap between model output and target by the target's standard error and squares it, which gives precise targets more influence. The same authors proposed avoiding the choice of weights by keeping every parameter set on the Pareto frontier, the sets for which no other set fits every target as well or better.
Source: Enns et al. 2015
What should an HTA reviewer check about the calibration targets in a health economic model submission?
A reviewer such as a NICE External Assessment Group can ask for the list of calibration targets with their sources and populations, the uncertainty attached to each, the weights with the reason for them, and a plot of modelled against observed values for each target. Results under alternative weights or target sets show how far the ICER rests on these choices. Documentation is often thin. Ghabri and colleagues report a pilot review of 77 manufacturers' cost-effectiveness analyses received by the French HAS between 2013 and 2017, which found a general lack of transparent documentation of attempts to adjust model parameters to fit known outcomes.
Source: Ghabri et al. 2019
Does a close fit to calibration targets show that a health economic model is valid?
Eddy and colleagues, in the ISPOR-SMDM report on model transparency and validation, call a validation dependent when the same source is used both to estimate model parameters and to validate the model, and they describe dependent validations as closely related to calibration. A model that reproduces its own targets has therefore passed a dependent check only. Independent validation needs a source that contributed no information to the model, such as a separate study kept out of calibration, while data held back from a source already used as a target give at best what the report calls a partially dependent validation. The same report asks that calibration reporting include the target, goodness-of-fit metric, search algorithm, acceptance criteria and stopping rule.
Source: Eddy et al. 2012
Trust Record
Verified by Dr Darrin Baines
British health economist
Professional identity: darrinbaines.org
Verification date: 12 Nov 2026
Content version: 1.0.0
Canonical Identity
- Persistent URI
- https://healtheconomics.wiki/concept/calibration-target
- Term code
- HE-EM-MV-124
Stable URI · Machine-readable · Resolvable · CC BY 4.0
