Author-reviewedEvidence: highv1.0.3

Applicability Assessment

Applicability assessment judges whether an economic evaluation or model fits a decision problem's population, comparators, care setting and methods.

Status
Published, version 1.0.3
Last reviewed
20 Oct 2026, by Dr Darrin Baines
Report a problem
Tell us if something is wrong or out of date

Concept Architecture

Applicability Assessment and Whether Evidence Fits the Decision

Applicability assessment asks whether a published economic evaluation, a model or a data source answers the question a particular decision maker faces, in that decision maker's setting. A well-conducted study can still fail it by covering the wrong patients, omitting a relevant comparator, reflecting another country's care pathway or using methods the local reference case does not accept. Because cost-effectiveness depends on prices, practice patterns and populations, a ratio from one setting is rarely a ready answer for another. NICE's checklist separates applicability from study limitations, and external validity, transferability frameworks and local re-pricing all bear on the same judgement.

Fit to the decision versus quality of the study

Health economists appraising evidence ask two separate questions. One is whether the study was done well, and the other is whether it is about the decision at hand. A rigorous evaluation of the wrong comparison is of little use, while a relevant study with flaws may still inform a judgement if the flaws are unlikely to change the conclusion.

The NICE guidelines manual (PMG20) builds this split into its appraisal checklist for economic evaluations. Section 1 covers applicability, meaning relevance to the review question and the NICE reference case, and is used first to filter out irrelevant studies. Section 2 covers study limitations and is used only once a study is judged sufficiently applicable. The manual states that inclusion of economic evaluations depends on the applicability of the evidence to NICE's decision-making context, usually the reference case.

The NICE technology appraisal manual (PMG36) applies a similar test. Published economic evaluations should be critically assessed with a suitable tool and their external validity assessed in relation to the decision problem (section 3.3.26), and they can replace de novo modelling if they are adequate and appropriate (section 3.3.27).

The NICE applicability checklist item by item

Section 1 of the PMG20 checklist has seven items and an overall judgement. Each item is answered yes, partly, no, unclear or not applicable, with reasons recorded in a comments column.

ItemWhat is judgedGuidance on the answer
1.1Study populationMatches the scope and review protocol, with important subgroups separated
1.2Interventions comparedAll relevant alternatives, including routine and best practice in UK settings
1.3Care systemSufficiently like the current UK context; old UK studies may no longer reflect practice
1.4Perspective on costsUsually NHS and personal social services for NHS-funded interventions with health outcomes
1.5Perspective on outcomesAll direct health effects for NHS-funded interventions with health outcomes
1.6Discounting3.5% a year for costs and effects; 3% on both counts as partly
1.7Outcome measureQALYs from EQ-5D with the UK value set, or a suitable social care equivalent

Item 1.3 carries most of the cross-country judgement. The manual's example is an intervention delivered residentially in one country and in the community in the UK, which may change resource use and costs substantially. A non-UK study is answered partly when setting differences are unlikely to change the cost-effectiveness estimates substantively, and no when the results are unlikely to apply.

The overall judgement sorts each study into three classes. A study is directly applicable if it meets all criteria, or fails some in a way unlikely to change the conclusions about cost effectiveness; partially applicable if a failed criterion could change them; and not applicable if a failed criterion is likely to change them, in which case it is usually excluded. The rating appears as its own column in the economic evidence profile the committee reads. In the manual's worked profile, adapted from the NICE Crohn's disease guideline, a model designed for the Swedish healthcare setting is rated partially applicable and the model built for the guideline directly applicable.

Applicability across jurisdictions

When evidence comes from another country, applicability assessment draws on the transferability literature. The ISPOR good research practices task force report by Drummond and colleagues observed that there are many reasons why the cost-effectiveness of health technologies might vary from place to place, and recommended practices based on individual patient data and on decision-analytic modelling. HIQA's Irish economic evaluation guidelines summarise its working definitions. An evaluation is generalisable if it can be applied elsewhere without adjustment, and transferable if it can be adapted to apply.

Transferability tools such as Welte and colleagues' decision chart and the adaptation toolkit of the European Network for Health Technology Assessment (EUnetHTA) structure this judgement; the adaptation page covers them and how a study is then modified.

External validity in two senses

The phrase external validity is used in two ways that both bear on applicability. In evidence appraisal, PMG36 says external validity is assessed according to the generalisability of trial evidence to wider patient groups and routine clinical practice (section 3.3.6), and notes that results may not generalise because of the relevance of the comparator, population, setting and treatment pathway (section 3.3.8).

In model appraisal, the ISPOR-SMDM task force on transparency and validation lists five types of validation, one of which is external validation, which compares a model's results with actual event data, such as a clinical trial's. The report states that validation information can be used by decision makers to determine the results' applicability to their decision, and its face validity questions include whether the setting, population, interventions, outcomes, assumptions and time horizons correspond to those of interest. Applicability assessment therefore sits alongside model validation, since a model can reproduce its source data well and still answer a different question.

Worked example of re-pricing a foreign evaluation

All numbers are illustrative. A published evaluation from Country A, in currency units (CU), compares a new drug with standard care and reports disaggregated resource use. The drug costs 5,000 CU a patient and avoids 2.0 hospital bed days at 500 CU each, for a gain of 0.20 QALYs. The study discounted at 3% a year and used a Country A value set.

1. Reproduce the published result.

ΔC=5,000−2.0×500=4,000,ICER=ΔCΔE=4,0000.20=20,000\Delta C = 5{,}000 - 2.0 \times 500 = 4{,}000, \qquad \text{ICER} = \frac{\Delta C}{\Delta E} = \frac{4{,}000}{0.20} = 20{,}000

where ΔC\Delta C is the incremental cost per patient in CU, ΔE\Delta E is the incremental QALYs per patient and ICER is the incremental cost-effectiveness ratio in CU per QALY gained.

2. Convert the published ratio. At an illustrative 0.80 GBP per CU, the incremental cost becomes 3,200 GBP and the ratio 16,000 GBP per QALY, with Country A's relative prices and care pathway unchanged.

3. Re-price with local unit costs. With a local drug price of 4,500 GBP and a bed day cost of 400 GBP, resource use held at Country A levels, the costs change as follows.

ΔC=4,500−2.0×400=3,700,ICER=3,7000.20=18,500\Delta C = 4{,}500 - 2.0 \times 400 = 3{,}700, \qquad \text{ICER} = \frac{3{,}700}{0.20} = 18{,}500

where ΔC\Delta C is now in GBP and the ICER in GBP per QALY.

4. Apply the local pathway. Local standard care is mostly community based, so the drug avoids only 1.0 bed day.

ΔC=4,500−1.0×400=4,100,ICER=4,1000.20=20,500\Delta C = 4{,}500 - 1.0 \times 400 = 4{,}100, \qquad \text{ICER} = \frac{4{,}100}{0.20} = 20{,}500

where the symbols are as in step 3.

5. Record the checklist judgement. Against an illustrative cost-effectiveness threshold of 20,000 GBP per QALY, the converted 16,000 and the re-priced 18,500 sit below it and the localised 20,500 above. The care system difference alone changes the conclusion, so item 1.3 cannot be answered partly. Item 1.6 is partly (3% on both, against 3.5%) and item 1.7 is partly because the QALYs did not use the UK value set. The published study is at best partially applicable; the 20,500 GBP figure is a local re-analysis, reported as such, with the QALY gain still carried over unadjusted.

Conversion changed only the unit of account. The conclusion turned on local prices and, above all, on how care is organised.

Using the judgement in decisions

Applicability ratings shape which evidence a committee sees and how much weight it carries. NICE evidence profiles report applicability beside limitations, incremental costs, incremental effects and uncertainty, so a committee can see when the only favourable evidence is partially applicable. PMG20 states that original economic analyses should only be done if an existing analysis cannot easily be adapted, so poor applicability often triggers new modelling.

Where a setting difference might or might not matter, sensitivity analysis is the usual test. Welte and colleagues suggest one-way analysis to find the adjustments that matter most, and multivariate or probabilistic analysis to express transfer uncertainty when not every parameter can be localised. Scenario analysis can show whether a different care pathway, as in step 4, reverses the conclusion.

Boundaries with nearby ideas

Several neighbouring concepts share vocabulary with applicability assessment but answer different questions. Keeping them apart makes it clear which judgement a reviewer is recording.

  • Study limitations ask whether a study is internally sound; NICE scores them in a separate checklist section.
  • Transferability and generalisability describe a property of the evidence; applicability assessment is the judgement made for one decision, often using transferability tools.
  • Adaptation is the work done after the assessment, when a partially applicable study is modified for the target setting.
  • External validation of a model tests outputs against observed data; a well-validated model can still be inapplicable.
  • GRADE indirectness rates down clinical evidence that does not directly match the population, interventions or outcomes of interest; the GRADE handbook labels differences in population as applicability.

Where applicability judgements go wrong

Applicability is a judgement, and the checklists structure it without removing the need for it. Four errors recur in reviews and submissions.

  1. Treating country of origin as decisive. The NICE checklist lets a non-UK study be partly applicable on setting when differences are unlikely to change the estimates, and warns that old UK studies may no longer reflect practice.
  2. Assuming currency conversion fixes applicability. PMG36 asks for costs from other countries to be converted to pounds sterling with an exchange rate from a current source (section 4.4.13), but conversion cannot correct differences in resource use. Sculpher and colleagues argue that simple exchange rates do not reflect opportunity cost and favour purchasing power parities.
  3. Confusing a good quality score with relevance. A study with minor limitations can still be not applicable.
  4. Expecting published studies to report enough detail. Sculpher and colleagues found that few trial-based studies give decision makers enough evidence to establish relevance or adjust results to their location, and recommend reporting resource use separately from unit costs.

Sources

  • Chase D, Rosten C, Turner S, Hicks N, Milne R. Development of a toolkit and glossary to aid in the adaptation of health technology assessment (HTA) reports for use in different contexts. Health Technology Assessment. 2009;13(59). https://doi.org/10.3310/hta13590
  • Drummond M, Barbieri M, Cook J, Glick HA, Lis J, Malik F, Reed SD, Rutten F, Sculpher M, Severens J. Transferability of economic evaluations across jurisdictions: ISPOR Good Research Practices Task Force report. Value in Health. 2009;12(4):409-418. https://doi.org/10.1111/j.1524-4733.2008.00489.x
  • Eddy DM, Hollingworth W, Caro JJ, Tsevat J, McDonald KM, Wong JB. Model transparency and validation: a report of the ISPOR-SMDM Modeling Good Research Practices Task Force-7. Value in Health. 2012;15(6):843-850. https://doi.org/10.1016/j.jval.2012.04.012
  • Health Information and Quality Authority. National Guidelines for the Economic Evaluation of Health Technologies in Ireland. Dublin: HIQA; 2025. Section 2.18. https://www.hiqa.ie/sites/default/files/2025-03/Economic-Evaluation-Guidelines.pdf
  • National Institute for Health and Care Excellence. Developing NICE guidelines: the manual (PMG20). London: NICE; 2014, updated October 2025. Chapter 7 and Appendix H. https://www.nice.org.uk/process/pmg20
  • National Institute for Health and Care Excellence. NICE technology appraisal and highly specialised technologies guidance: the manual (PMG36). London: NICE; 2022, last updated 13 October 2026. Sections 3.3.6, 3.3.8, 3.3.26, 3.3.27 and 4.4.13. https://www.nice.org.uk/process/pmg36
  • Schünemann H, Brożek J, Guyatt G, Oxman A, editors. GRADE handbook for grading quality of evidence and strength of recommendations using the GRADE approach. Updated October 2013. Section 5.2.3. https://gdt.gradepro.org/app/handbook/handbook.html
  • Sculpher MJ, Pang FS, Manca A, Drummond MF, Golder S, Urdahl H, Davies LM, Eastwood A. Generalisability in economic evaluation studies in healthcare: a review and case studies. Health Technology Assessment. 2004;8(49). https://doi.org/10.3310/hta8490
  • Welte R, Feenstra T, Jager H, Leidl R. A decision chart for assessing and improving the transferability of economic evaluation results between countries. PharmacoEconomics. 2004;22(13):857-876. https://doi.org/10.2165/00019053-200422130-00004

Institutional Perspectives (1)

  • PBAC

    Tabulate Trial Versus Australian Setting Differences and Test Those That Matter

    The PBAC guidelines ask each submission to tabulate important differences between the trial setting and the Australian setting after listing, covering the population, disease severity, circumstances of use, concomitant treatments and the health care system. Each difference is judged either unlikely to have an effect or as needing further investigation, which is then addressed through translation analyses in the economic evaluation. Differences that may affect comparative effectiveness or safety can undermine the assumptions needed for a cost-minimisation approach and then call for a supplementary analysis.

    Pharmaceutical Benefits Advisory Committee, Guidelines for preparing a submission to the Pharmaceutical Benefits Advisory Committee, Version 5.0 (September 2016), subsections 2.7.1 and 2.7.2View source →

Library

Publications

1
  • Journal article

    Model Transparency and Validation: A Report of the ISPOR-SMDM Modeling Good Research Practices Task Force-7 — Eddy, Hollingworth, Caro, Tsevat, McDonald & Wong, Task Force Report 7 ed., 2012 (Value in Health / Medical Decision Making)

    Best-practice guidance on model transparency and validation, defining face, internal, external and predictive validation and setting out how models should be documented for scrutiny.

Frequently Asked Questions (6)

  • What is applicability assessment?

    Applicability assessment judges whether an economic evaluation or model fits a decision problem's population, comparators, care setting and methods.

    Source: NICE PMG20 (2014, updated 2025)

  • Why can a well-built model still be inapplicable?

    A model can be internally sound, with correct calculations and reasonable structure, yet still be wrong for the decision at hand if it was built for a different population, setting, or comparator. Applicability assessment checks this match, asking whether the patients, practice, costs, and question the model represents are those the decision concerns. A model developed in one country or for one indication may not transfer, however good it is in its original context. Suitability for the specific decision is separate from technical quality. Eddy and colleagues (2012) discuss this check.

    Source: Eddy et al. 2012

  • Why is applicability assessment important?

    Applicability assessment is important because a model, however well built, gives valid results only for the question it is designed and suited to answer, so using it for a different population, comparator, or setting can mislead. Checking applicability ensures the model's structure, population, and assumptions match the decision at hand. This is particularly relevant when reusing or adapting an existing model, since its choices may not transfer. Applicability assessment thus prevents a technically sound model from being misapplied to a question it does not fit.

    Source: Eddy et al. 2012

  • What does applicability assessment examine?

    Applicability assessment examines whether the model's population matches the patients relevant to the decision; whether its interventions and comparators are those of interest; whether its outcomes and perspective suit the question; and whether its structure and assumptions are appropriate for the context and setting. It considers how well the model, including any it was adapted from, fits the specific decision. Where these do not match, the model may need adaptation or may be unsuitable, so the assessment establishes the model's relevance to the question.

    Source: Roberts et al. 2012

  • When is applicability assessment especially needed?

    Applicability assessment is especially needed when an existing model is reused or adapted for a new question, since its structure, population, and assumptions were chosen for the original decision and may not suit the new one, and when a model built in one setting or country is applied to another with different practice or costs. It is also needed when appraising a model built by others. In these cases, checking applicability guards against using a model beyond the scope for which it is valid.

    Source: Eddy et al. 2012

  • How does applicability assessment relate to model validation?

    Applicability assessment complements the other parts of model validation. While verification checks the model is built correctly and validation checks its outputs against evidence and clinical plausibility, applicability assessment checks that the model, even if sound, suits the particular decision question. A model can be correctly built and internally valid yet inapplicable to the question at hand. Applicability assessment therefore addresses fitness for the specific purpose, ensuring the validated model is also appropriate for the decision it is being used to inform.

    Source: Eddy et al. 2012

Trust Record

Verified by Dr Darrin Baines

British health economist

Professional identity: darrinbaines.org

Verification date: 20 Oct 2026