Author-reviewedv1.0.1

Premarket Approval

Premarket approval (PMA) is the FDA review a high-risk Class III medical device must pass before US sale, on evidence of its safety and effectiveness.

Last reviewed byDr Darrin Baines

Concept Architecture

Premarket Approval of High-Risk Medical Devices

Premarket approval, usually shortened to PMA, is the US Food and Drug Administration (FDA) decision that allows a Class III medical device, such as a pacemaker or an implantable cardioverter-defibrillator, to be sold once the agency finds reasonable assurance that it is safe and effective for its intended use. The FDA calls it "the most stringent type of device marketing application", yet it answers a narrower question than a payer or health technology assessment body, which asks whether the device is worth funding. For health economists the PMA file, and above all its public Summary of Safety and Effectiveness Data (SSED), is often the main clinical evidence available at launch. Its comparators, follow-up and study populations therefore shape the uncertainty in early device cost-effectiveness models.

Where premarket approval sits among US device pathways

US law sorts devices into three classes by the controls needed to give reasonable assurance of safety and effectiveness. Under 21 CFR 860.3 a device is Class III when general and special controls are insufficient and it is life-supporting or life-sustaining, of substantial importance in preventing impairment of human health, or presents a potential unreasonable risk of illness or injury. Part 814 covers Class III devices that were not on the market before 28 May 1976 and are not substantially equivalent to an earlier device or one in a lower class.

Most devices reach the US market by other routes. A 510(k) premarket notification ends in an order that the device is substantially equivalent to a legally marketed predicate, with the same intended use and, if its technology differs, no different questions of safety and effectiveness (21 CFR 807.100). The De Novo route places a new type of device with no predicate in a lower class than Class III (21 CFR 860.200).

PathwayQuestion answeredFDA standard fee, FY 2027
510(k) premarket notificationSubstantially equivalent to a predicate deviceUSD 28,653
De Novo classification requestNew device type with no predicate, placed below Class IIIUSD 191,020
Premarket approval (PMA)Reasonable assurance of safety and effectiveness of a Class III deviceUSD 636,732

From 1987 to 2020, Darrow and colleagues found a median of 32 novel devices granted premarket approval each year against a median of 3,404 510(k) clearances.

What a PMA must show and how it is reviewed

The evidential test sits in 21 CFR 860.7. The FDA relies only on valid scientific evidence, which runs from well-controlled investigations through partially controlled studies and trials without matched controls to well-documented case histories. Effectiveness evidence must consist principally of well-controlled investigations unless the agency accepts other valid evidence, and safety is shown when probable benefits outweigh probable risks. The statute requires the FDA to consider the least burdensome appropriate means of evaluating effectiveness and whether premarket data can be reduced through reliance on postmarket controls, a trade between evidence before launch and evidence after it.

The application itself must summarise the indications for use, alternative practices or procedures for the condition, and the clinical investigations, including adverse reactions, device failures and replacements, and the results of statistical analyses (21 CFR 814.20). Clinical studies of an unapproved device can be run under an investigational device exemption, and the PMA must identify any investigation conducted that way.

The FDA decides within 45 days whether to file the application, the 180-day review period runs from filing, and an advisory panel may review the application at a public meeting. Approval must be refused if there is no showing of reasonable assurance of safety or effectiveness under the proposed labelling. On approval the FDA makes public a detailed summary of the safety and effectiveness information behind the order, the SSED.

Supplements, postapproval studies and recalls

An approved PMA is a living file. A PMA supplement must be approved before a change that affects safety or effectiveness, such as a new indication or a design change (21 CFR 814.39), and the FDA may impose postapproval requirements, including continuing evaluation and periodic reporting on safety, effectiveness and reliability (21 CFR 814.82).

Much of the evidence arrives after launch, if at all. For cardiac implantable electronic devices, Rome and colleagues counted 77 original PMAs and 5,829 supplements approved from 1979 to 2012, a median of 50 supplements per original approval, and only 23% (15 of 64) of the 180-day supplements approved from 2010 to 2012 included new clinical data. Rathi and colleagues found that about 13% of initiated postmarket studies of high-risk therapeutic devices approved in 2010 and 2011 were completed 3 to 5 years after approval. Of 193 original high-risk therapeutic devices approved through PMA from 2014 to 2023, Mooghali and colleagues found that 68 (35.2%) had at least one serious recall by 31 July 2025.

Evidence at launch and the gap with HTA needs

The evidence that clears the regulatory bar is often thin by HTA standards. Dhruva and colleagues reviewed 78 PMAs for high-risk cardiovascular devices and found that 33 of 123 supporting studies (27%) were randomised, 51 of 78 approvals (65%) rested on a single study and 187 of 213 primary end points (88%) were surrogate measures. Among the studies that formed the basis of approval for high-risk therapeutic devices in 2010 and 2011, Rathi and colleagues found that 13 of 30 had no comparator and that median follow-up of the primary effectiveness end point was 3.0 months.

Each of these features maps onto a modelling problem. A single-arm study leaves the comparator effect to be borrowed from elsewhere, a surrogate endpoint must be linked to survival or quality of life, and a few months of follow-up must be extended over a lifetime time horizon by extrapolation, a source of structural uncertainty. The MedtecHTA project added device-specific challenges, such as device and user interaction and incremental innovation, and recommended high quality registries and iterative evaluation over time, so real-world evidence is expected to fill some of the gaps that the PMA leaves open.

Medicare coverage after FDA approval

In the United States the coverage decision is taken separately, mainly by the Centers for Medicare and Medicaid Services (CMS). In an August 2026 notice CMS explained that the FDA applies a statutory standard of safety and effectiveness while CMS asks whether an item is reasonable and necessary for people with Medicare, so FDA authorisation alone does not entitle a device to coverage. CMS added that older beneficiaries with multiple comorbidities may be underrepresented in the studies the FDA reviews, and that it looks for evidence on health outcomes in the Medicare population and on the durability of those outcomes.

Where evidence is limited, a national coverage decision can be made under coverage with evidence development, which pays for a technology while studies continue. The Transitional Coverage for Emerging Technologies pathway, finalised in August 2024, expedites national coverage for certain Breakthrough Devices, with no more than five candidates a year expected. The same August 2026 notice proposed the RAPID pathway for Breakthrough-designated Class II and Class III devices, with a proposed national coverage determination released on the day of FDA authorisation and a final one about 90 days later for Class III devices. CMS noted that higher-risk devices are more likely to reach authorisation with evidence gaps remaining.

Worked example of durability and the ICER at launch

All numbers in this example are illustrative. A Class III implant costs USD 30,000 more per patient than medical therapy, including the implant procedure. Its main premarket study followed patients for 12 months and showed a gain of 0.05 QALYs in that year. Costs and effects are left undiscounted, and no downstream cost offsets are counted, to keep the arithmetic visible.

If the benefit is counted only for the 12 months observed, the ICER is

ICER=ΔCΔE=300000.05=600000\text{ICER} = \frac{\Delta C}{\Delta E} = \frac{30000}{0.05} = 600000

where ΔC\Delta C is the incremental cost in USD and ΔE\Delta E is the incremental QALYs per patient. If the benefit of 0.05 QALYs a year lasts for 5 years, ΔE=5×0.05=0.25\Delta E = 5 \times 0.05 = 0.25 and

ICER=300000.25=120000\text{ICER} = \frac{30000}{0.25} = 120000

where the incremental cost is unchanged because the device is paid for once.

If instead the benefit wanes by 0.01 QALYs each year to zero after 5 years, ΔE=0.05+0.04+0.03+0.02+0.01=0.15\Delta E = 0.05 + 0.04 + 0.03 + 0.02 + 0.01 = 0.15 and

ICER=300000.15=200000\text{ICER} = \frac{30000}{0.15} = 200000

Against an illustrative threshold of USD 150,000 per QALY, only the constant-benefit case looks good value. The 12-month study cannot distinguish the second case from the third, so the decision turns on a durability assumption that the approval evidence does not test. Value of information analysis can then show whether longer follow-up, through postapproval studies or coverage with evidence development, is worth paying for.

Premarket approval and EU conformity assessment

The EU has no central approval decision for devices. Under the Medical Device Regulation (EU) 2017/745, a Class III device undergoes conformity assessment by a notified body, a conformity assessment body designated under the Regulation, through Annex IX or through Annex X coupled with Annex XI. Clinical investigations must be performed for implantable and Class III devices except in defined cases, mainly modified versions of a marketed device whose equivalence the notified body endorses, and for Class III implantable devices the notified body must also consult an expert panel on the clinical evaluation. The outcome is CE marking rather than an agency approval order, so conformity assessment is the closest EU counterpart to PMA, as marketing authorisation is for medicines.

The EU then links this step to HTA. Under Regulation (EU) 2021/2282, applied from 12 January 2025, Class IIb and Class III devices that received an expert panel opinion under that consultation may be selected for joint clinical assessment, with selection by implementing act at least every two years.

Common misreadings of premarket approval

Approval is not evidence of value. A PMA says nothing about cost, the comparators payers care about or affordability, which early health technology assessment tries to anticipate during development.

PMA does not imply a randomised controlled trial. The regulations accept partially controlled studies, and fewer than a third of the cardiovascular studies reviewed above were randomised.

An approved model is not necessarily the studied model. For cardiac implantable electronic devices many models in use were approved through supplements, mostly without new clinical data, so an economic model built on the original study may describe a device that is no longer sold.

Clearance and approval are different findings. A 510(k) clearance rests on substantial equivalence to a predicate device, so describing a cleared device as "FDA approved" overstates the evidence behind it.

Sources

Institutional Perspectives (1)

  • FDA

    Class III Devices Need Premarket Approval Before Marketing

    The FDA describes premarket approval as its scientific and regulatory review of the safety and effectiveness of Class III medical devices, which support or sustain human life, are of substantial importance in preventing impairment of human health, or present a potential unreasonable risk of illness or injury. It calls PMA the most stringent type of device marketing application. The applicant must obtain approval before marketing the device, and approval rests on a finding of sufficient valid scientific evidence that the device is safe and effective for its intended use.

    FDA, Premarket Approval (PMA) web page, Overview, content current as of 16 May 2019View source →

Library

Publications

19
  • Other

    Medicare program; Regulatory Alignment for Predictable and Immediate Device (RAPID) coverage pathway. Notice with comment period — Centers for Medicare and Medicaid Services, Vol. 91, No. 153, pp. 51710-51718 ed., 2026 (Federal Register)

    Source listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Premarket Approval, where it is cited as a reference for that concept.

  • Other

    Medicare program; Transitional Coverage for Emerging Technologies. Final notice — Centers for Medicare and Medicaid Services, Vol. 89, No. 155, pp. 65724-65754 ed., 2024 (Federal Register)

    Source listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Premarket Approval, where it is cited as a reference for that concept.

  • Journal article

    FDA regulation and approval of medical devices: 1976-2020 — Darrow JJ, Avorn J, Kesselheim AS, Vol. 326, No. 5, pp. 420-432 ed., 2021 (JAMA)

    Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Premarket Approval, where it is cited as a reference for that concept.

  • Journal article

    Strength of study evidence examined by the FDA in premarket approval of cardiovascular devices — Dhruva SS, Bero LA, Redberg RF, Vol. 302, No. 24, pp. 2679-2685 ed., 2009 (JAMA)

    Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture articles on Premarket Approval and Investigational Device Exemption, where it is cited as a reference for that concept.

  • Journal article

    Exploring the comparability of face-to-face versus video conference-based composite time trade-off interviews — Estévez-Carrillo A, Dewilde S, Oppe M, Ramos-Goñi JM, Vol. 15, No. 5, pp. 521-535 ed., 2022 (The Patient)

    Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Interviewer Bias, where it is cited as a reference for that concept.

  • Other

    Regulation (EU) 2017/745 of 5 April 2017 on medical devices — European Parliament and Council of the European Union, L 117 ed., 2017 (Official Journal of the European Union)

    Source listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Premarket Approval, where it is cited as a reference for that concept.

  • Journal article

    Test-treatment RCTs are susceptible to bias: a review of the methodological quality of randomized trials that evaluate diagnostic tests — Ferrante di Ruffano L, Dinnes J, Sitch AJ, Hyde C, Deeks JJ, Vol. 17, Article 35 ed., 2017 (BMC Medical Research Methodology)

    Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Hierarchy of Diagnostic Efficacy, where it is cited as a reference for that concept.

  • Other

    Medical device user fee rates for fiscal year 2027 — Food and Drug Administration, Vol. 91, No. 145, pp. 48134-48142 ed., 2026 (Federal Register)

    Source listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Premarket Approval, where it is cited as a reference for that concept.

  • Journal article

    Does mode matter? A comparison of telephone, mail, and in-person treatments in contingent valuation surveys — Maguire KB, Vol. 90, No. 11, pp. 3528-3533 ed., 2009 (Journal of Environmental Management)

    Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Interviewer Bias, where it is cited as a reference for that concept.

  • Other

    Clinical Negligence Scheme for Trusts — NHS Resolution, Web page, accessed 14 October 2026 ed., 2026 (NHS Resolution)

    Source listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Medical Malpractice, where it is cited as a reference for that concept.

  • Journal article

    A systematic review of barriers to and facilitators of the use of evidence by policymakers — Oliver K, Innvar S, Lorenc T, Woodman J, Thomas J, Vol. 14, Article 2 ed., 2014 (BMC Health Services Research)

    Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Knowledge Brokering, where it is cited as a reference for that concept.

  • Journal article

    Diagnostic tests often fail to lead to changes in patient outcomes — Siontis KC, Siontis GC, Contopoulos-Ioannidis DG, Ioannidis JP, Vol. 67, No. 6, pp. 612-621 ed., 2014 (Journal of Clinical Epidemiology)

    Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Hierarchy of Diagnostic Efficacy, where it is cited as a reference for that concept.

  • Other

    Federal Food, Drug, and Cosmetic Act, sections 513 and 515 (21 USC 360c and 360e) — Ferrante di Ruffano L, Dinnes J, Sitch AJ, Hyde C, Deeks JJ, Web page, accessed 14 October 2026 ed., 2026 (Legal Information Institute, Cornell Law School)

    Source listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Premarket Approval, where it is cited as a reference for that concept.

  • Other

    21 CFR Part 814, Premarket approval of medical devices; 21 CFR Part 860, Medical device classification procedures; 21 CFR 807.100 — Food and Drug Administration, eCFR, current to 9 October 2026 ed., 2026 (Electronic Code of Federal Regulations)

    Source listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Premarket Approval, where it is cited as a reference for that concept.

  • Other

    Premarket approval (PMA) — Food and Drug Administration, 2019 (Food and Drug Administration)

    Source listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Premarket Approval, where it is cited as a reference for that concept.

  • Journal article

    Premarket clinical evidence strength and recalls of high-risk therapeutic medical devices — Mooghali M, Arshad F, Rathi VK, et al, Vol. 7, No. 8, Article e262626 ed., 2026 (JAMA Health Forum)

    Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture articles on Premarket Approval and Investigational Device Exemption, where it is cited as a reference for that concept.

  • Journal article

    Characteristics of clinical studies conducted over the total product life cycle of high-risk therapeutic medical devices receiving FDA premarket approval in 2010 and 2011 — Rathi VK, Krumholz HM, Masoudi FA, Ross JS, Vol. 314, No. 6, pp. 604-612 ed., 2015 (JAMA)

    Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Premarket Approval, where it is cited as a reference for that concept.

  • Journal article

    FDA approval of cardiac implantable electronic devices via original and supplement premarket approval pathways, 1979-2012 — Rome BN, Kramer DB, Kesselheim AS, Vol. 311, No. 4, pp. 385-391 ed., 2014 (JAMA)

    Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Premarket Approval, where it is cited as a reference for that concept.

  • Journal article

    Key recommendations from the MedtecHTA project — Tarricone R, Torbica A, Drummond M; MedtecHTA Project Group, Vol. 26, No. Suppl 1, pp. 145-152 ed., 2017 (Health Economics)

    Journal article listed in the Sources of the HealthEconomics.wiki Concept Architecture article on Premarket Approval, where it is cited as a reference for that concept.

Frequently Asked Questions (6)

  • What is premarket approval (PMA)?

    Premarket approval (PMA) is the FDA review a high-risk Class III medical device must pass before US sale, on evidence of its safety and effectiveness.

    Source: FDA 2019

  • When does a medical device need premarket approval rather than 510(k) clearance?

    The FDA applies premarket approval requirements to Class III devices, which support or sustain human life, are of substantial importance in preventing impairment of human health, or present a potential unreasonable risk of illness or injury. For these devices the agency has determined that general and special controls alone are insufficient. If a new device is substantially equivalent to a device already cleared through a 510(k) premarket notification, the applicant should submit a 510(k) instead. A high-risk device found not substantially equivalent must have an approved PMA before US marketing, although some other devices found not substantially equivalent may be eligible for the De Novo process as Class I or Class II devices.

    Source: FDA 2019

  • How strong is the clinical evidence behind premarket approval of high-risk cardiovascular devices?

    Dhruva and colleagues reviewed the summaries of safety and effectiveness data for 78 premarket approvals of high-risk cardiovascular devices granted between 2000 and 2007. Only 33 of the 123 supporting studies (27%) were randomised and 17 (14%) were blinded. Of the 78 approvals, 51 (65%) rested on a single study, and 187 of 213 primary end points (88%) were surrogate measures. For a cost-effectiveness model this means the comparator effect often has to be borrowed from other sources, and surrogate end points have to be linked to survival or quality of life before they can yield QALYs.

    Source: Dhruva et al. 2009

  • How do devices change after premarket approval, and why does it matter for economic models?

    Rome and colleagues studied cardiac implantable electronic devices such as pacemakers and implantable cardioverter-defibrillators. From 1979 to 2012 the FDA approved 77 original premarket approval applications and 5,829 supplements for these devices, a median of 50 supplements per original approval. Among 180-day supplements approved from 2010 to 2012, only 23% (15 of 64) included new clinical data. Many models in clinical use were therefore approved through supplements, mostly without new clinical data. An economic model built on the original approval study may describe a device that is no longer sold, so analysts need to check which version the evidence refers to.

    Source: Rome et al. 2014

  • Does premarket approval guarantee Medicare coverage of a device?

    In an August 2026 notice, CMS explained that the FDA decides on marketing against a statutory standard of safety and effectiveness, while CMS asks whether an item is reasonable and necessary for people with Medicare, so FDA authorisation alone does not entitle a device to coverage. CMS added that older beneficiaries with multiple comorbidities may be underrepresented in the studies the FDA reviews, and that it looks at health outcomes in the Medicare population and their durability. Where evidence is limited, coverage with evidence development pays while studies continue. The notice also proposed the RAPID pathway for Breakthrough-designated devices, noting that higher-risk devices are more likely to reach authorisation with evidence gaps.

    Source: CMS 2026

  • What is the EU counterpart of premarket approval for Class III medical devices?

    The EU has no central approval decision for devices. Under the Medical Device Regulation (EU) 2017/745, a Class III device undergoes conformity assessment by a notified body, a conformity assessment body designated under the Regulation, through Annex IX or through Annex X coupled with Annex XI. Clinical investigations must be performed for implantable and Class III devices except in defined cases, mainly modified versions of a marketed device whose equivalence the notified body endorses. For Class III implantable devices the notified body must also consult an expert panel on the clinical evaluation, and the outcome is CE marking rather than an agency approval order.

    Source: European Parliament and Council 2017

Trust Record

Verified by Dr Darrin Baines

British health economist

Professional identity: darrinbaines.org

Verification date: 14 Oct 2026

Content version: 1.0.1

Canonical Identity

Term code
HS-HP-HSR-067

Stable URI · Machine-readable · Resolvable · CC BY 4.0